MSE PRO Gas Chromatography–Mass Spectrometry (GC-MS) System, Model 2
SKU: MA2679
MSE PRO™ Gas Chromatography–Mass Spectrometry (GC-MS) System, Model 2
Key Features
- Inlet Vacuum
- Ion Source: Standard EI (Electron Ionization)
- High-Performance Gas Chromatograph: Equipped with an EPC system and a 7-inch touchscreen display
- Clarity Software: Fully compliant with GLP and FDA 21 CFR Part 11 standards
Structure
- Sample Introduction
- Ion Source: Standard EI (Electron Ionization)
- Quadrupole Mass Analyzer
- Detector: Electron Multiplier
Specification
| Data processing system | |
| Data acquisition and processing platform | multi-core parallel processing technology and high-speed electronic circuit design |
| Software | customized Clarity software |
| SIM/Scan | SIM/Scan Data synchronization acquisition |
| SIM/Scan Data synchronization acquisition | guarantees full mass range scanning during full analysis time without significant loss of sensitivity |
| NIST library optional | |
| Software fully supports GLP/FDA-21CFR Part11 electronic signature certification, data validity security, system certification tool (IQ/OQ) and system suitability test (SST) requirements | |
| Mass spectrometer | |
| Ion source | high transmission efficiency Focusing inert EI source |
| Ion source temperature | 50-350 °C |
| Electronic energy | 0-300eV |
| Filament emission current | 0-300µA |
| Mass filter | quadrupole |
| Mass range | 1.5-1100 u |
| Mass shaft stability | better than ±0.10 u/48 hours |
| Detector | Triple off-axis detector with long-life electron multiplier |
| Full scan mode (SCAN) maximum time unlimited | |
| The foreline pump uses mechanical pump of not less than 130L/min, and the high vacuum uses turbomolecular pump of not less than 70L/s | |
| Gas chromatography | |
| Column oven control system | |
| Temperature range | 5 ° C ~ 420 ° C (increment 0.1 ° C) |
| Temperature control accuracy of the oven | better than ±0.05 °C (measured at 200 °C) |
| Program temperature control | 20 ramps / 21 platform program temperature, software operation ramp is unlimited |
| Maximum rate of program increase | 80 ° C / min (increment 0.1 ° C) |
| Cooling speed | 350℃~100℃≤3min |
| Carrier gas control system | |
| Outlet connection method | atmospheric pressure and vacuum mode |
| Number of carrier gas pressure blocks | 3 segments |
| Carrier gas flow program number | 3 segments |
| Flow range | 0~1000mL/min(He, H2),(Factory default:He) 0~200mL/min(N2,Ar), (Factory default: N2) |
| Tail blow | 0~100mL/min |
| Reference gas | 0~150mL/min |
| Pressure range | 0~100psi |
| Set resolution | 0.01psi |
| Maximum split ratio | 5000:1 |