MSE PRO Cell Fusion System for Electrofusion/Electroporation

  • £5,32400
  • Save £63800


MSE PRO™ Cell Fusion System for Electrofusion/Electroporation

The MSE PRO™ Cell Fusion System utilizes pulses of electric fields that can induce the fusion of neighboring cells (electrofusion) or create a porous cell membrane (electroporation) to allow for transfection of macromolecules. Both techniques are reproducible and non-toxic techniques widely used in researching cell-cell interactions and intracellular pathways. Many applications have clinical significance in diagnostic testing, therapeutics and vaccine development.

Offered in 4 different electrode spacings and volume inputs

  • SKU# MA1005: 0.5mm Electrode Spacing, 20μL volume input
  • SKU# MA1006: 1.0mm Electrode Spacing, 40μL volume input
  • SKU# MA1007: 2.0mm Electrode Spacing, 80μL volume input
  • SKU# MA1008: 3.2mm Electrode Spacing, 700μL volume input

Applications

  • Stem cell development
  • Nuclear transfer for transgenic development 
  • Production of hybridomas (fusion of B-cells and Myeloma cells) for antibody expression
  • Genetically modified plant protoplast, tetraploid fusion
  • Embryo manipulation
  • Live gene/drug introduction

Specifications

 SKU # MA1005 MA1006 MA1007 MA1008
Electrode Spacing (mm) 0.5 1.0 2.0 3.2
Sample Input Volume (μL) 20 40 80 700
Dimensions (LxWxH, mm) 450x370x290 450x370x290 450x370x290 450x370x290
Power Source (V/Hz) 110/60 110/60 110/60 110/60

 

Performance Descriptions

For maintenance of the machine, simply clean frequently using a mild cleaning agent and then disinfect with Ethanol. 

 Performance Description
String AC electric field frequency 1MHz-2.5MHz (optimal stable value) Biological cells can be arranged in strings in an alternating electric field and come into contact with each other. This frequency is designed for a wide range to provide the best frequency choice for the arrangement and fusion of different types of cells or protoplasts of animals, plants, and microorganisms
String AC electric field voltage 1-58V This voltage range can collect cells ranging from plant protoplasts to bacterial volumes. This voltage range also meets the voltage needs of large volume fusion chambers with wide electrode spacing.
Fusion pulse voltage range 5-600V This voltage range allows biological cells of any size to induce confluence in fusion chambers at different pole distances.
Gate time 10-1000US The AC field can be turned off at a set time when a fusion pulse is applied. This is equivalent to inserting a DC pulse into the AC pulse.
Pulse width 5-5000US Precisely control the timing of fusion pulses. Inducing fusion with multiple short pulses yields higher cell viability than confluence with a single long pulse.
Pulses 1-9 Adjusting the number of fusion pulses applied adds a selection index to determine the optimal fusion conditions for biological cells.

 

Alternating Electrical Field Parameters

Square Wave Series Pulse Voltage Peak-to-peak 1-58V, continuously adjustable
Square Wave Series Pulse Frequency 30KH-3000KHz, continuously adjustable
Gate time 10-1000μs, adjustable in 1μs increments, continuously adjustable

 

Direct Current Electrical Field Parameters

Square Wave Fusion Pulse Voltage 5-600V, continuously adjustable, field strength up to 6000V/cm with electrode spacing of 1.0mm
Square Wave Fusion Pulse Width 5-600V, continuously adjustable, field strength up to 6000V/cm with electrode spacing of 1.0mm
Square Wave Fusion Pulse Cycles 1-9
Randomly Matched Plate Electrodes:  Electrode spacing of 1mm, 2mm
Display Mode 7-inch TFT Touchscreen
Optional Electrodes Microscope Slide