Menu

Jacketed Standard Electrochemical Cell

  • $ 75095
  • Save $ 9100


This is a stationary solution jacketed standard electrochemical (electrolytic) cell for measurements of electrodes in a form of: a) rod/disc (6 mm dia.), b) thin film deposited on flat substrate (using a sample holder) and c) membrane (using a clip electrode). The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. A temperature of an electrolyte can be controlled by circulation of a fluid agent between thermostat bath and the jacketed vial. The cell has two spare ports for connection of e.g. thermometer, Clark electrode, pH meter electrode, or other 6 mm dia. electrode/probe.
The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. The non-jacketed model is available here.

Application note
This is a stationary solution jacketed standard electrochemical (electrolytic) cell for measurements of electrodes in a form of: a) rod/disc (6 mm dia.), b) thin film deposited on flat substrate (using a sample holder) and c) membrane (using a clip electrode). The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. A temperature of an electrolyte can be controlled by circulation of a fluid agent between thermostat bath and the jacketed vial. The cell has two spare ports for connection of e.g. thermometer, Clark electrode, pH meter electrode, or other 6 mm dia. electrode/probe.
The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. The non-jacketed model is available here.

Specification
maximum electrolyte volume: 100, 150, 200, 250, 350, 500 or 1000 mL
electrode plug diameter: 6 mm
number of electrode ports: 5
vial material: borosilicate 3.3 glass
hose connector type: multi barb
recommended tube size: ID 8.0 mm

Product includes
1 x lid
2 x adjustable handle
1 x jacketed vial
1 x working electrode mount
3 x plug – 0005CPEMA