Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

MM Spectro-EFC, 4 mm path, 0.7 mL - Magnetic Mount Spectro-Electrochem– MSE Supplies LLC

Overstock Sale - Select Products 10% Off on Orders of $500 or More! Promo Code:

SAVING10

Shop Now
Menu

This product has been added to the cart.

MM Spectro-EFC, 4 mm path, 0.7 mL - Magnetic Mount Spectro-Electrochemical Flow Cell with reduced optical path

SKU: C016A

  • £1,95400
  • Save £23400



This is a horizontally mounted, multi-purpose spectroelectrochemical cell with 4 mm long optical path (i.e. electrolyte thickness) designed to be used with standard UV-Vis or IR spectrometers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin film in systems where variations in applied potential induce changes in observed spectra. It consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. Unlike Spectro-EFC 1.75 mL, this cell is meant to be used with pseudo-reference electrode (50 mm long) and counter electrode in the form of a metal wire (90 mm long), both with plug of 6 mm in diameter. Thanks to the application of pseudo-reference electrode, the thickness of an electrolyte is reduced from 12 mm down to 4 mm.

Application note
Spectroelectrochemical cell is used to study the relation between absorbance/transmittance and electrochemical potential. It enables real-time monitoring of optical change in electrochromic materials. It also enables in-situ spectral acquisition for detection, identification and characterization of short-lived electrochemically-generated species/intermediates, resulting in a detailed investigation of the mechanistic pathways of redox processes.

Specification
nominal exposure area: 1 cm2 (other values on request)
optical path length (electrolyte thickness): 4 mm
flow chamber volume: 0.7 mL
maximum substrate thickness: 4 mm
electrode plug diameter: 6 mm
minimum substrate size: 17 mm x 25 mm
recommended substrate size: 25 mm x 25 mm

Product includes
1 x sample mount – 0049CPEMAMM
1 x flow chamber – 0050CPEMAMM
1 x quartz window - 0045PQGMA
1 x window holder - 0051PSSMA
1 x set of screws – 0032PNYCM
1 x plug – 0005CPEMA
1 x Manfrotto PIXI table tripod – 0028PHYCM
1 x XS Bendy Flexible Tripod - 0043PHYCM