Menu
MSE PRO Biological Safety Cabinet (Class II BSC) - MSE Supplies LLC

MSE PRO Biological Safety Cabinet (Class II, Type A2 BSC)

  • £5,65500
  • Save £62200


MSE PRO™ Biological Safety Cabinet (Class II, Type A2 BSC)

Class II Biological Safety Cabinets (BSC) ensure a high level of protection for the operator, product and environment, minimizing hazards inherent to working with biosafety levels 1, 2 and 3 agents and maintaining a sterile environment for your needs. 

1300 Series: 1300mm (51.2in/4.3ft) width of Cabinet

1500 Series: 1500mm (59in/4.9ft) width of Cabinet

1800 Series: 1800mm (70.9in/5.9ft) width of Cabinet

Features: 

  • Includes BSC, Power Cord, Fuses (2 ea.) and Product Manual
  • 7-in touch screen interface that displays fan operations, front window state, filter, sterilization lamp life percentage, alarm status, and operation logs
  • High efficiency and energy saving
  • Pressure sensor monitors airflow based on filter resistance 
  • High quality steel and lacquered in ivory
  • Comfortable working area 
  • Ergonomic design
  • Easy to clean

Certification: EN 12469

Specifications

SKU # LS0226 LS0227 LS0228
Series
1300 Series
1500 Series
1800 Series
External dimensions WxDxH (mm) 1300x807x2240 1500x807x2240 1800x810x2207
Internal dimensions WxDxH (mm) 1180x580x798 1380x580x798 1680x580x798
Support Base WxDxH (w/ Wheels, mm) 1285x710x680 1485x710x670 1800x710x645
Weight (kg) 265 312 375
Power Supply 110V, 60Hz
110V, 60Hz
110V, 60Hz
Filtration Efficiency >99.9995%, @0.12μm >99.9995%, @0.12μm >99.9995%, @0.12μm
Air Supply and Exhaust Filters ULPA Filters ULPA Filters ULPA Filters
Air Cleanliness ISO 4 Class ISO 4 Class ISO 4 Class
Execution Standards

YY0569(GB 4793.1

GB/T 18268.1)

YY0569(GB 4793.1

GB/T 18268.1)
YY0569(GB 4793.1

GB/T 18268.1)
Down Flow Velocity (m/s) 0.35 0.35 0.35
Inflow Velocity (m/s) 0.55 0.55 0.55
Noise Level (dB) <65 d <65 d <65 d
Vibration <5μm (center of tabletop) <5μm (center of tabletop) <5μm (center of tabletop)
Personnel Protection A.Total colony in impaction sampler <10CFU./time B. Total colony in slot sampler <5CFU./time
A.Total colony in impaction sampler <10CFU./time B. Total colony in slot sampler <5CFU./time
A.Total colony in impaction sampler <10CFU./time B. Total colony in slot sampler <5CFU./time
Product Protection Total colony in culture dish <5CFU./time Total colony in culture dish <5CFU./time Total colony in culture dish <5CFU./time
Cross-Contamination Protection Total colony in culture dish <2CFU./time Total colony in culture dish <2CFU./time Total colony in culture dish <2CFU./time

Max Consumption (w/ Spare Socket, kW)

1.65 1.65 1.65
Rated Power (w/o Spare Socket) 0.33 0.33 0.33
Size and Qty. of Light 18Wx1 18Wx1 18Wx1
Size and Qty. of UV Light 20Wx1 20Wx1 20Wx1
Lumin.  ≥900LX ≥900LX ≥900LX
Cabinet Materials High-grade steel and lacquered in ivory High-grade steel and lacquered in ivory High-grade steel and lacquered in ivory
Working Area Materials SS304 fully finished SS304 fully finished SS304 fully finished
Air Direction Top out Top out Top out
Air Quality ISO 4 in accordance with ISO CD 14644-1: 353 part. ≥0.5 μm/m3; 10000 part. ≥0.1 μm/ m3