Total Carbonyl Colorimetric Assay Kit

  • $ 59595


Total Carbonyl Colorimetric Assay Kit

SKU # E-BC-K171-S
Detection Instrument Spectrophotometer (370 nm)
Detection method Colorimetric method


Product Details

Properties

Sample Type Serum, plasma, tissue
Sensitivity 0.94 μg/mL
Detection Range 0.94-45 μg/mL
Detection Method Colorimetric method
Assay type Quantitative
Assay time 50 min
Precision Average inter-assay CV: 8.300% | Average intra-assay CV: 4.400%
Other instruments required Micropipettor, Vortex mixer
Other reagents required Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage 2-8℃
Valid period 12 months


Detection Principle

Carbonyl can react with 2,4-dinitrophenylhydrazine and produce a kind of reddish brown hydrazone compounds, which has a specific absorbance peak at 370 nm. The content of carbonyl can be calculated according to the absorbance value.

 

Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Total carbonyl content (μg/mL) Dilution factor
<45 1
45-50 10

 

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Kit Components & Storage

Item Component Size 1
(50 assays)
Size 2
(100 assays)
Storage
Reagent 1 Working Solution 15 mL × 1 vial 30 mL × 1 vial 2-8°C, 12 months, shading light
Reagent 2 100 µg/mL Standard 1 mL × 1 vial 2 mL × 1 vial 2-8°C, 12 months

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (μg/mL) 4.60 18.50 36.20
%CV 4.7 4.2 4.3


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (μg/mL) 4.60 18.50 36.20
%CV 8.3 8.1 8.5

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 100%.

Standard 1 Standard 2 Standard 3
Expected Conc. (μg/mL) 12.5 26.8 39.2
Observed Conc. (μg/mL) 12.6 28.1 36.8
Recovery rate (%) 101 105 94

 

Sensitivity

The analytical sensitivity of the assay is 0.94 μg/mL. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only.

Concentration (μg/mL) 0 5 10 20 30 40 45
Average OD 0.358 0.375 0.395 0.434 0.473 0.511 0.525
Absoluted OD 0 0.017 0.037 0.076 0.115 0.153 0.167