Kofloc Liquid Vortex Flow Meter with Temperature Correction

Kofloc Liquid Vortex Flow Meter with Temperature Correction

SKU: KFML-301-I-N

  • $ 21306


Request a Quote

Kofloc Liquid Vortex Flow Meter with Temperature Correction

Buy KOFLOC Products from MSE Supplies at the best value.

  • Liquid:
    • Ultrapure water, chemicals, and other liquids
  • Flow range:
    • Liquid 2.5~250L/min
  • Accuracy:
    • ±2~3%F.S.
    • Temperature sensor measures fluid temperature and temperature correction reduces accuracy errors due to changes in fluid temperature.
    • Wetted part New PFA (O-ringless).
    • Compact design.
    • Wide flow range available from 0.3~2.5L/MIN to 10~250L/MIN.
    • Water resistance equivalent to IP65.
    • CE

    Download Manual   

    Drawings  

    Specifications:

    MODEL

    FML-301

    FML-302

    FML-303

    FML-304

    FML-305

    Connection

    3/8" tube end

    1/2" tube end

    3/4" tube end

    1" tube end

    1 (1/2)" tube end

    Flow range

    0.3 to 2.5L/min

    0.4 to 4.0L/min

    2.0 to 16L/min

    5.0 to 50L/min

    10 to 100L/min

    Fluid

    Water, pure water, chemical solution

    Accuracy

    ±2%F.S. (25°C)

    ±3%F.S. (25°C)

    Temperature accuracy

    ±2°C ±0.15×ΔT°C (ΔT: Ambient temperature - Fluid temperature)

    Repeatability

    ±0.5%F.S.

    Fluid temperature

    0°C to 90°C (no freezing and boiling)

    Accuracy guarantee temperature

    Fluid temperature 15°C to 60°C

    Max working pressure

    1MPa(G) @25°C

    0.75MPa(G) @25°C

    0.65MPa(G) @25°C

    Allowable ambient temperature

    0°C to 50°C (no freezing)

    Allowable ambient humidity

    95%RH or less (no dew condensation)

    Storage temperature

    -10°C to 70°C (no freezing)

    Protective structure

    Equivalent to IP65 (drip-proof dust-proof)

    Materials of parts in contact with liquid

    New PFA

    Output

    Flow rate output

    Without display

    Current: 4 to 20mA, Allowable load resistance: 250Ω to 500Ω at 24VDC input, 250Ω or less at 12VDC input or
    pulse output (1kHz at F.S. Duty: 50%, NPN open collector output: Max. 30VDC / 80mA)

    With display

    Current: 4 to 20mA, Allowable load resistance: 250Ω to 500Ω at 24VDC input, 250Ω or less at 12VDC input or
    pulse output (1kHz at F.S. Duty: 50%, NPN open collector output: Max. 30VDC / 80mA)
    Integrated flow output: Pulse output

    Temperature output
    (only when water runs)

    Without display

    1-5VDC (0°C to 100°C), External load resistance: 250kΩ or more

    With display

    Current: 4 to 20mA (0°C to 100 °C), Allowable load resistance: 250Ω to 500Ω at 24VDC input, 250Ω or less at 12VDC input

    Alarm output

    Alarm contacts: 2points NPN open collector output, Max. 30VDC / 80mA (only with display)

    Digital communication

    RS485 (MODBUS protocol, RTU mode) (only with display)

    Power supply

    12 to 24VDC ±10%, Current consumption (80mA or less without display, 140mA or less with display)

    Cable length

    3m terminated, preliminary soldering

    Weight

    Without display

    160g or less

    175g or less

    200g or less

    With display

    165g or less

    180g or less

    205g or less