ATTO WSE-3200 Power Station III
SKU: WSE-3200
ATTO WSE-3200 Power Station III
Buy ATTO products from MSE Supplies at the best Value.
Purpose and Application:
- Slab/mini-slab electrophoresis (polyacrylamide gel electrophoresis)
- Small disc (isoelectric point) Electrophoresis
- Agarose gel electrophoresis
- Semi-dry rotting can be used
under certain conditions (please contact us for conditions for use in blotting)
Features:
- ~1000V, ~500mA, ~200W output configurable
- Programmable output settings Free: 21 files, chained: 10 files
- Output conditions such as electrophoresis have already been input (preset)
- Original output conditions can be saved (memory)
- Large dial for easy configuration
- Reliable accuracy, stability, and safety features
- Easy-to-read display Large LED, two-stage display
| Applicable | WSE-3100 | WSE-3400 | WSE-3500 | WSE-3200 |
|---|---|---|---|---|
| Wet (Tank) blotting | ⭕️ | ❌ | ⭕️ | ❌ |
| Submerge Agaros gel | ⭕️ | ⭕️ | 🔺 | ⭕️ |
| Semi-Dry blotting | ⭕️ | 🔺 | ⭕️ | 🔺 |
| Plate IEF Smaller than 10 x 10 cm | 🔺 | ❌ | ❌ | 🔺 |
| PAGE gel Smaller than 10 x 10 cm | ⭕️ | ⭕️ | 🔺 | ⭕️ |
| PAGE gel Larger than 10 x 10 cm | ⭕️ | ⭕️ | ❌ | ⭕️ |
| Large PAGE (Sequence gel) | 🔺 | ❌ | ❌ | 🔺 |
| Faster Semi-Dry blotting | ⭕️ | 🔺 | ⭕️ | 🔺 |
| Disc IEF | ⭕️ | 🔺 | ❌ | ⭕️ |
| Cooling PAGE | ⭕️ | ❌ | ❌ | ⭕️ |
| ⭕️ Applicable | 🔺 Restricted by condition | ❌ not applicable |
MSE Supplies is an authorized distributor of ATTO products.
Technical Data:
| Model and name | WSE-3200 Power Station III. |
|---|---|
| output | Voltage: 10~1000V (Display 1000=Full) (Max. 200W) Current : 0~500mA (Display 0~) (Max. 200W) Power : 0~200W (Display 0~) |
| establishment | Voltage: 10~1000V 1V steps Current : 1~500mA 1mA steps Power : 1~200W 1W steps |
| Output terminals | 4 sets of parallel outputs |
| timer | 1~999min, continuous 1min step countdown |
| Control Functions | Constant Voltage, Current, and Power Crossover |
| Control unit | Display: 7seg LED 3 digits x 2 columns Setting: Large Dial |
| Alarm Output | Electronic buzzer key input (1 time), error occurrence (1 time), time up (5 times) |
| Output accuracy | Voltage: 10~50V or less for set value±1.5V 51V ~150V for set value ±3%+5digits 151V ~1000V ±2%+5digits for set value |
| Display accuracy | Voltage: Within ± (0.2% of RDG+5digits) Current value: Within ± (0.5% of RDG+5digits) Power : Within ± (0.5% of RDG+5digits) |
| Conditional memory | Preset: 23 files P01~P23 Free: 21 files U00~U20, 10 files C01-C10 (chain files) |
| Safety Features | Output Short Circuit Detection: Short-Circuit Current (Short) Leak Detection: Leakage Current to Ground (Leakage) Open Detection: Load Release (Open) Arc Detection: Discharge State (ARC) Input High Voltage Detection: Input Voltage 265V or More Fan Stop Detection: Fan Failure Internal temperature detection: equipment internal temperature rise |
| Measures against power outages | After power is restored, it automatically returns to the state before the power outage. |
| Cooling method | Forced air cooling with built-in fan |
| Usage environment | Temperature 0°C~+40°C, Humidity 20~90%RH Non-condensing |
| Input voltage | AC100~240V |
| frequency | 50/60Hz |
| Power Consumption | 300W or less |
| Safety Standards | Compliant with the Electrical Appliance and Material Safety Act |
| material | Case ABS |
| size | 96(W)x325(D)x195(H)mm |