MSE PRO 46mm x 62mm Dry Pouch Cell without electrolyte, 2.0 Ah (Cathode: NCM811, Anode: Silicon-Carbon)
Couldn't load pickup availability
Still have questions? Ask our experts!
MSE PRO 46mm x 62mm Dry Pouch Cell without electrolyte, 2.0 Ah (Cathode: NCM811, Anode: Silicon-Carbon)
Introduction
These are electrolyte-free dry pouch cells with stable material properties. They can be directly filled with electrolyte for cell performance testing.
Specifications
| Battery Model + Electrodes | 4662 2Ah (NCM811 / Si-carbon) |
| Content of Active Substances (%) | Cathode: 95.5% / Anode: 94% |
| Double-Sided Density (mg/cm²) | Cathode: 32 ± 0.2 / Anode: 15 ± 0.2 |
| Compacted Density (g/cm³) | Cathode: 3.4 ± 0.1 / Anode: 1.4 ± 0.1 |
| Recommended Test Voltage Range (V) | 2.8 – 4.25 |
| Recommended Electrolyte | Special electrolyte for silicon-carbon systems |
| Recommended electrolyte infusion volume (g/Ah) | 3.5 |
| Reference Internal Resistance after injection /mΩ | ≤ 15 |
Operation procedure for battery testing
1. Battery Electrolyte Injection
Refer to the dosage reference table; administration should be performed in a glove box.
2. Battery Aging
Aging temperature: 45°C; duration ≥15 hours; aging completed in an oven.
3. Battery Formation
- battery test cabinet:
- Lithium battery: 25°C, rest for 5 min → charge at 0.02C for 5 h → charge at 0.1C for 3 h; one cycle.
- Horizontal Thermal Pressing Formation Machine:
- 45°C, pressure 3.5 kg/cm²
- Charge at 0.02C for 5 h → charge at 0.1C for 3 h
- One cycle completed
4. Battery Aging (Secondary)
Aging temperature: 45°C; duration ≥24 hours.
5. Battery Capacity Division
Set the corresponding material cutoff voltage and cycle twice with a current level of 0.1C or 0.2C.
6. Battery Testing
Set the magnification or repeat the process step to test the battery.
MSE offers a range of battery consumables. Please contact us for more information.