MSE PRO 46mm x 62mm Dry Pouch Cell without electrolyte, 1.5 Ah (Cathode: NCM811, Anode: Graphite)
Couldn't load pickup availability
Still have questions? Ask our experts!
MSE PRO 46mm x 62mm Dry Pouch Cell without electrolyte, 1.5 Ah (Cathode: NCM811, Anode: Graphite)
Introduction
These are electrolyte-free dry pouch cells with stable material properties. They can be directly filled with electrolyte for cell performance testing.
Specifications
| Battery Model + Electrodes | 4662 Dry Cell (NCM811 / Graphite) |
| Content of Active Substances (%) | Cathode: 95% / Anode: 93.20% |
| Double-Sided Density (mg/cm²) | Cathode: 21 ± 0.4 / Anode: 12.6 |
| Compacted Density (g/cm³) | Cathode: 3.27 / Anode: 1.4 |
| Recommended Test Voltage Range (V) | 3.0 – 4.3 |
| Recommended electrolyte infusion volume (g/Ah) | 3.5 |
| Recommended Electrolyte | LB-092 |
| Reference Internal Resistance after injection /mΩ | ≤ 15 |
Operation procedure for battery testing
1. Battery Electrolyte Injection
Refer to the dosage reference table; administration should be performed in a glove box.
2. Battery Aging
Aging temperature: 45°C; duration ≥15 hours; aging completed in an oven.
3. Battery Formation
- battery test cabinet:
- Lithium battery: 25°C, rest for 5 min → charge at 0.02C for 5 h → charge at 0.1C for 3 h; one cycle.
- Horizontal Thermal Pressing Formation Machine:
- 45°C, pressure 3.5 kg/cm²
- Charge at 0.02C for 5 h → charge at 0.1C for 3 h
- One cycle completed
4. Battery Aging (Secondary)
Aging temperature: 45°C; duration ≥24 hours.
5. Battery Capacity Division
Set the corresponding material cutoff voltage and cycle twice with a current level of 0.1C or 0.2C.
6. Battery Testing
Set the magnification or repeat the process step to test the battery.
MSE offers a range of battery consumables. Please contact us for more information.