MSE PRO Gas Chromatography–Mass Spectrometry (GC-MS) System, Model 2
Couldn't load pickup availability
Ships on pallet – Freight delivery required
Must be delivered to a location that can accept large truck shipments
Still have questions? Ask our experts!
MSE PRO™ Gas Chromatography–Mass Spectrometry (GC-MS) System, Model 2
Key Features
- Inlet Vacuum
- Ion Source: Standard EI (Electron Ionization)
- High-Performance Gas Chromatograph: Equipped with an EPC system and a 7-inch touchscreen display
- Clarity Software: Fully compliant with GLP and FDA 21 CFR Part 11 standards
Structure
- Sample Introduction
- Ion Source: Standard EI (Electron Ionization)
- Quadrupole Mass Analyzer
- Detector: Electron Multiplier
Specification
| Data processing system | |
| Data acquisition and processing platform | multi-core parallel processing technology and high-speed electronic circuit design |
| Software | customized Clarity software |
| SIM/Scan | SIM/Scan Data synchronization acquisition |
| SIM/Scan Data synchronization acquisition | guarantees full mass range scanning during full analysis time without significant loss of sensitivity |
| NIST library optional | |
| Software fully supports GLP/FDA-21CFR Part11 electronic signature certification, data validity security, system certification tool (IQ/OQ) and system suitability test (SST) requirements | |
| Mass spectrometer | |
| Ion source | high transmission efficiency Focusing inert EI source |
| Ion source temperature | 50-350 °C |
| Electronic energy | 0-300eV |
| Filament emission current | 0-300µA |
| Mass filter | quadrupole |
| Mass range | 1.5-1100 u |
| Mass shaft stability | better than ±0.10 u/48 hours |
| Detector | Triple off-axis detector with long-life electron multiplier |
| Full scan mode (SCAN) maximum time unlimited | |
| The foreline pump uses mechanical pump of not less than 130L/min, and the high vacuum uses turbomolecular pump of not less than 70L/s | |
| Gas chromatography | |
| Column oven control system | |
| Temperature range | 5 ° C ~ 420 ° C (increment 0.1 ° C) |
| Temperature control accuracy of the oven | better than ±0.05 °C (measured at 200 °C) |
| Program temperature control | 20 ramps / 21 platform program temperature, software operation ramp is unlimited |
| Maximum rate of program increase | 80 ° C / min (increment 0.1 ° C) |
| Cooling speed | 350℃~100℃≤3min |
| Carrier gas control system | |
| Outlet connection method | atmospheric pressure and vacuum mode |
| Number of carrier gas pressure blocks | 3 segments |
| Carrier gas flow program number | 3 segments |
| Flow range | 0~1000mL/min(He, H2),(Factory default:He) 0~200mL/min(N2,Ar), (Factory default: N2) |
| Tail blow | 0~100mL/min |
| Reference gas | 0~150mL/min |
| Pressure range | 0~100psi |
| Set resolution | 0.01psi |
| Maximum split ratio | 5000:1 |
Frequently Asked Questions
What is included in the GC-MS system?
A gas chromatograph with EPC and a 7-inch touchscreen, a standard EI ion source, a quadrupole mass analyzer, an electron multiplier detector and Clarity software.
Does the software support regulated labs?
Yes. It supports GLP and FDA 21 CFR Part 11 electronic signatures, data security, IQ/OQ tools and system suitability tests.
Is a spectral library available?
The NIST library is available as an option. Contact us for a quote with the configuration you need.