MSE PRO™ Gas Chromatograph with Dual FID
Technical Features
- The host machine adopts a 7-inch color touch screen with friendly man-machine interface.
- Computer back control and host touch screen to achieve synchronous bidirectional control.
- The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
- Carrier/hydrogen/air flow (pressure) digital display.
- Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
- Split flow/split ratio can be automatically controlled to save carrier gas.
- Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
- Data acquisition is a standard dual-channel data acquisition card with a sampling time of 50ms.
- Using logarithmic amplification plate, detection signal no cut-off value, synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
- It has perfect system self-check function and fault automatic identification function.
- With eight external event extension function interface, can be selected with a variety of control valves, and according to their own set time sequence work.
- The external link mode is network port connection (RJ45), which provides convenience for remote control of data.
Column temperature box
- Temperature range: 5℃ ~ 400℃ at room temperature
- Temperature control accuracy: ±0.1℃
- Program heating: stage 9/10 platform
- Total program time: 9999.9 min
- Maximum heating rate: 60℃ / min
Sampler
- Temperature range: 7℃ ~ 420℃ at room temperature
- Fill column, split/split sampler can be installed
- Working under constant pressure mode
- No more than three independent sampling systems are connected simultaneously
Detector
- A maximum of 2 units are installed simultaneously. FID, TCD, ECD and FPD are optional.
- Flow/pressure is displayed directly on the screen.
- Temperature setting: Max. 420℃
Hydrogen flame ionization detector (FID)
- High voltage switch control
- Baseline signal display
- Ignition coil control
- Detection limit: ≤3×10-12 g/s
- Sample: N-hexadecane (minimum detection quantity: 3pg/s)
- Dynamic range: 107
Thermal conductivity detector (TCD)
- Bridge voltage switch control
- Bridge current setting: 0 ~ 220 mA
- Sensitivity: 5000 mV•mL/mg
- Dynamic range: 105
Electronic capture detector (ECD)
- Radiation source: Ni63
- Detection limit: ≤8×10-14g/s
- Sample: R 666 (minimum detection quantity: 80FG/s)
- Dynamic range: 103
Flame photometric detector (FPD)
- Temperature setting: Maximum 350℃
- Detection Limit: ≤2×10-12 g/s (P); ≤4×10-11 g/s (s) sample: Methyl parathion
- Dynamic range: P 103
- Dynamic range: S 102
Heating area
- In addition to the column box independent heating area, there are six heating areas. 2 injector heating zones, 2 detector heating zones and 2 auxiliary heating zones.
- The maximum operating temperature of the auxiliary heating area can reach 400℃