MSE PRO Compact On‑Deck Fluorescence Reader
Couldn't load pickup availability
Still have questions? Ask our experts!
MSE PRO™ Compact On‑Deck Fluorescence Reader
Description
The fluorescence reader is an extremely compact on deck fluorometer module for microvolume nucleic acid quantification and protein concentration measurement. The device operates on the principle of fluorescent dye method, allowing simultaneous fluorescence quantification of 8 samples to obtain precise test results.
It is specifically designed for automated workstations, focusing on post-extraction nucleic acid concentration quantification and quality control of the DNA input in NGS library preparation workstations. The device can be controlled via the workstation, and when integrated with a robotic arm, it facilitates automated workflow. Its compact design takes up just one 96-well plate position on deck, and it can be tailored and adapted to accommodate different workstation setups based on the workflow.
Features
Rapid Detection
It can accurately detect nucleic acid concentration within 3 to 5 seconds.
Microvolume
Requires only 1-20 μL of sample to provide accurate results.
Precision
High sensitivity for effective quantification of low-concentration nucleic acids and proteins.
Specificity
Specific detection for dsDNA , ssDNA, RNA, and proteins, unaffected by other substances in the sample.
Flexibility
Offers users the flexibility to choose from a range of fluorescence assays, not limited to reagents provided by a specific manufacturer. Compatible with various reagent brands, including the Qubit® series and other fluorescence assay reagents, you can achieve the dsDNA HS assay, dsDNA BR assay, RNA HS assay, RNA BR assay, microRNA assay, RNA extended Range assay and Protein BR assay.
![]()
![]()
300 samples of dsDNA were tested on‑deck fluorescence reader, and 20 repeatability tests were performed on different types of competitor Q respectively, and on‑deck fluorescence reader has a good linear correlation with competing products.
20 repeatability tests were performed on different types of samples on‑deck fluorescence reader and Micro spectrophotometer respectively. low-concentration samples, the stability of the fluorometer detection results is higher.
![]()
![]()
According to the standard kit method, 10 repeatability tests were performed on‑deck fluorescence reader and competitor Q for spectrophotometer. Using with lambda DNA content between 0.25-67.5ng, and the specifically accuracy of the test results was compared.
The detectable sample concentration range on‑deck fluorescence reader and micro- corresponding assay kits, on‑deck fluorescence reader can detect various types of DNA/RNA.
Using standard test kit, dsDNA with a concentration on of 0.025-13.5 ng/ul was measured on‑deck fluorescence reader and competitor Q for 100 times, and the accuracy of the measurement results were compared
The detectable sample concentration range on‑deck fluorescence reader and UV spectrophotometer.
The working process of fluorometer:
![]()
Specification
|
Specification |
Parameter |
|
SKU |
MA0066625 |
|
Sample Volume |
1~20ul |
|
Sample Capacity |
8 |
|
Compatible Tube |
0.2mL Clear PCR Tube |
|
Test Time |
≤5s/sample |
|
Linearity Range |
5 orders of magnitude |
|
Light Source |
LED |
|
Excitation Wavelength |
Blue 460-480nm, |
|
Emission Wavelength |
Green500-535nm |
|
Detector |
SiPMT |
|
Sensitivity |
dsDNA 0.01ng/ul |
|
Test Item |
dsDNA High Sensitivity |
|
Calibration |
2points calibration through the host computer or the subordinate computer. |
|
Operation |
Controlled by the host computer and both the raw fluorescence values and concentration values can be uploaded. |
|
Operation Environment |
15-30℃, <75%, Indoor -use |
|
Dimension |
85.5mm*50mm*100mm, 0.25Kg |