MSE PRO Ion Chromatography System Model 4

Order upon Request
SKU: MA2609
Customization Icon
Customizable Product

Together with our experts we will create a product designed for your needs

Still have questions? Ask our experts!

MSE PRO™ Ion Chromatography System Model 4

Features

  • Cation and Anion Dual-Channel System: Both channels operate independently, ensuring no interference between them, allowing simultaneous detection of cations and anions.
  • Eluent Thermal Buffer System: Preheats the eluent before it enters the columns, preventing bubble formation caused by rapid heating.
  • Built-In Low-Pressure Degassing Technology: Eliminates bubble interference, enhancing system stability.
  • Advanced Chromatograph Column Series: Offers a full range of columns capable of detecting ions with diverse compositions.
  • Exceptional Performance: Designed to support all your application needs efficiently

Instrument Highlight

Major Standards

I. Ion Chromatographic Pump

  • Type: High-pressure, low-pulse, double-plunger series pump
  • Pressure Range: 0~42 MPa
  • Flow Range: 0.001~9.999 mL/min
  • Pressure Accuracy: ≤0.1 MPa
  • Flow Accuracy (Setting Error): RSD ≤0.1%

II. Digital Temperature-Control Detection System

Conductivity Detector

  • Structure: Temperature-controlled, bipolar conductivity detector
  • Detection Mode: Double conductivity detection
  • Conductance Cell Size: ≤0.8 µL
  • Output Voltage: -5000~5000 mV (adjustable)
  • Measurement Range: 0~30000 µS/cm (10 selectable levels)
  • Resolution: ≤0.025 nS
  • Conductance Cell Temperature: 5~50°C (adjustable)
  • Constant Temperature Accuracy: ±0.01°C
  • Baseline Noise: ≤0.6% FS
  • Baseline Drift: ≤2.0% FS
  • Qualitative Repeatability: ≤1%
  • Quantitative Repeatability: ≤1%

III. Flow System

  • Pipeline Material: Entirely made of PEEK plastic materials
  • Six-Way Valve: Rheodyne electromagnetic six-way valve (USA) with compression resistance of 7000 psi and automatic signal collection capability.

IV. Analytical Capability

1. High-Capacity Anion Column

  • Compatible with pH 0~14 and organic solvents.
  • Capable of analyzing multiple ions simultaneously, including:
    • F⁻, Cl⁻, NO₂⁻, PO₄³⁻, Br⁻, NO₃⁻, SO₄²⁻, ClO₂⁻, BrO₃⁻, ClO₃⁻.

2. High-Capacity Cation Column

  • Capable of separating and analyzing ions such as:
    • Lysine, Li⁺, Na⁺, NH₄⁺, K⁺, Mg²⁺, Ca²⁺, Sr²⁺, Ba²⁺, and choline chloride.

3. Detector Capabilities

  • Supports the detection of various transition metallic ions, heavy metallic ions, and special ions.

V. Performance Metrics

  • Analysis Repeatability: ≤1.0% (e.g., SO₄²⁻, Na⁺)
  • Linear Range: ≥10³
  • Minimum Detection Concentrations:
    • Cl⁻: ≤0.1 ppb
    • Na⁺: ≤5 ppb

Specification

Built-in Eluent Generator Eluent Types KOH/NaOH/LiOH/MSA
Eluent Concentration Range 0.1-100mM
Concentration Increment 0.1mM
Flow Rate Range 0.1-5.0 mL/min
Maximum Pressure 30 MPa
Minimum Pressure 5 MPa
Vacuum Degasser Vacuum Degree -70 kPa
Internal Volume 300 µL
Maximum Flow Rate 10 mL/min
Degassing Efficiency 1.0 mL/min (90%)
Degassing Volume 7.5 mL
Sensor Leakage Sensor Standard configuration
Gas-liquid Separator Gas-liquid Separator Configuration One (Standard configuration)
Flow Path Material Chemically inert,
metal-free PEEK flow paths,
compatible with aqueous eluents of pH 0-14
and reversed-phase solvents
Pump Type High-pressure and low-pulse two-piston tandem advection pump
Maximum Pressure 42 MPa
Flow Rate Range 0.001-9.999 mL/min
Pressure Ripple ≤0.5%
Flow Precision ≤0.1%
Flow Accuracy ≤0.1%
External Diameter of the Tube 1/16 inch
Column Heater Operating Temperature Range Ambient +5 to 60°C
Controlling Temperature Accuracy ±0.1°C
Temperature Stability ≤0.1°C/h
Column Supported 2, 3, 4 and 5 mm ID.
Maximum length 250 mm analytical column with 50
mm guard column
Conductivity Detector Type Auto-range conductivity detector
Cell Volume ≤0.8 µL
Detection Range 0~50000 µS/cm
Resolution ≤0.0020 nS/cm
Output Voltage -6000~+6000 mV (adjustable)
Electronic Noise 0.02 nS
Baseline Noise ≤0.0005 µS/cm
Baseline Drift ≤0.005 µS
Operating Temperature Range Ambient +5°C~60°C
Controlling Temperature Accuracy ±0.01°C
Temperature Compensation 1.7%/°C
Maximum Pressure 10.0 MPa
Linear Range ≥10³
Instrument Linearity ≥0.999
Quantitative Repeatability ≤0.5%
Qualitative Repeatability ≤0.2%
Minimum Detectable Concentration Cl⁻ ≤0.0004 µg/mL, Li⁺ ≤0.0001 µg/mL
Suppressor Type Self-Regeneration electrolytic micro-membrane suppressor
Maximum Pressure 6.0 MPa
Non-Suppressed Chromatography Yes/support
Void Volume <40 µL (4mm), <15 µL (2mm)
Power Supply 350W
External Size(L*W*H*) 500×500×760 mm
Net Weight (KG) 48
Gross Weight (KG) 73