MSE PRO Gas Chromatograph with Dual FID

Ready to Ship
SKU: LS4637
Regular price $ 19,405.95

Still have questions? Ask our experts!

MSE PRO™ Gas Chromatograph with Dual FID

Technical Features

  • The host machine adopts a 7-inch color touch screen with friendly man-machine interface.
  • Computer back control and host touch screen to achieve synchronous bidirectional control.
  • The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
  • Carrier/hydrogen/air flow (pressure) digital display.
  • Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
  • Split flow/split ratio can be automatically controlled to save carrier gas.
  • Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
  • Data acquisition is a standard dual-channel data acquisition card with a sampling time of 50ms.
  • Using logarithmic amplification plate, detection signal no cut-off value, synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
  • It has perfect system self-check function and fault automatic identification function.
  • With eight external event extension function interface, can be selected with a variety of control valves, and according to their own set time sequence work.
  • The external link mode is network port connection (RJ45), which provides convenience for remote control of data.

Column temperature box

  • Temperature range: 5 ~ 400 at room temperature
  • Temperature control accuracy: ±0.1
  • Program heating: stage 9/10 platform
  • Total program time: 9999.9 min
  • Maximum heating rate: 60 / min

Sampler

  • Temperature range: 7 ~ 420 at room temperature
  • Fill column, split/split sampler can be installed
  • Working under constant pressure mode
  • No more than three independent sampling systems are connected simultaneously

Detector

  • A maximum of 2 units are installed simultaneously. FID, TCD, ECD and FPD are optional.
  • Flow/pressure is displayed directly on the screen.
  • Temperature setting: Max. 420

Hydrogen flame ionization detector (FID)

  • High voltage switch control
  • Baseline signal display
  • Ignition coil control
  • Detection limit: ≤3×10-12 g/s
  • Sample: N-hexadecane (minimum detection quantity: 3pg/s)
  • Dynamic range: 107

Thermal conductivity detector (TCD)

  • Bridge voltage switch control
  • Bridge current setting: 0 ~ 220 mA
  • Sensitivity: 5000 mV•mL/mg
  • Dynamic range: 105

Electronic capture detector (ECD) 

  • Radiation source: Ni63
  • Detection limit: ≤8×10-14g/s
  • Sample: R 666 (minimum detection quantity: 80FG/s)
  • Dynamic range: 103

Flame photometric detector (FPD)

  • Temperature setting: Maximum 350
  • Detection Limit: ≤2×10-12 g/s (P); ≤4×10-11 g/s (s) sample: Methyl parathion
  • Dynamic range: P 103
  • Dynamic range: S 102

Heating area

  • In addition to the column box independent heating area, there are six heating areas. 2 injector heating zones, 2 detector heating zones and 2 auxiliary heating zones.
  • The maximum operating temperature of the auxiliary heating area can reach 400