MSE PRO Hydrophilic PP Separator film (135mm x 10m x 0.04mm) for Zinc Ion Battery
Introduction
The MSE PRO Hydrophilic PP Separator Film is engineered for high-performance zinc-ion battery applications. Constructed from a polypropylene (PP) membrane combined with non-woven fabric and treated through a sulfonation-based hydrophilic process, this separator offers excellent electrolyte wettability, enhanced ionic transport, and stable electrochemical performance.
The hydrophilic modification significantly improves electrolyte absorption and promotes uniform zinc-ion distribution, helping to enhance battery efficiency, cycling stability, and safety.
Applications
-
Zinc-ion battery separators
-
Aqueous rechargeable battery research
-
Advanced energy storage system development
Details
|
Category |
Item |
Description |
|
Basic Information |
Product Name |
Hydrophilic PP Membrane |
|
Material |
Modified Polypropylene (PP) |
|
|
Applicable Battery Type |
Zinc-ion Battery |
|
|
Product Advantages |
Solves the problem of poor electrolyte wettability of traditional |
|
|
Basic Parameters |
Surface Treatment |
Hydrophilic Groups |
|
Thickness |
0.04 ± 0.003 mm |
|
|
Areal Density |
21.3 g/m² |
|
|
Porosity |
41.20% |
|
|
Puncture Strength |
702.3 g |
|
|
Tensile Strength |
1674 kgf/cm² |
|
|
Liquid Absorption Rate |
Fully wetted in 5 seconds |
|
|
Heat Shrinkage Rate |
≤5% (100℃ 1h) |
|
|
Tensile Strength |
≥100 MPa |
|
|
Note |
The above parameters are average values and the |
|
|
Instructions for Use |
Prohibition of Over-limit Use |
The temperature should be <80°C and prolonged baking is not recommended. |
|
Storage Conditions |
Storage Environment |
Temperature 10-25°C (avoid freezing or high temperature) |
|
Best Use Period |
6 months |
|
|
Precautions |
Anti-pollution Operation |
Wear gloves during operation and do not touch the membrane |
|
Electrolyte Compatibility |
Only applicable to aqueous electrolytes with pH 4-14 (such as ZnSO₄ KOH-ZnO etc); Strictly |
|
|
Failure Warning |
If not used for a long time after opening it needs to be resealed |