MSE PRO Nickel cobalt manganese NCM613 (single crystal)
Couldn't load pickup availability
Consumables Product
This consumable product is not available for refund or return
Still have questions? Ask our experts!
MSE PRO™ Nickel cobalt manganese NCM613 (single crystal)
Product Details:
Lithium-ion battery positive electrode, Ni, Co, Mn NCM material, excellent cycling performance, high gram capacity and first effect
Specifications
| Test item | Unit | Specifications | Actual measurement results | Testing methods or instruments |
| Li | % | 7.0±1.0 | 7.42 | |
| Ni | % | 35.0±1.0 | 35.62 | |
| Co | % | 7.5±1.0 | 7.56 | |
| Mn | % | 16.5±1.0 | 16.22 | |
| Ni | mol% | / | 58.5 | ICP |
| Co | mol% | / | 12.1 | ICP |
| Mn | mol% | / | 29.5 | ICP |
| Fe | % | ≤0.01 | 0.0008 | ICP |
| Cu | % | ≤0.01 | 0 | ICP |
| Zn | % | ≤0.01 | 0.0002 | ICP |
| Na | % | ≤0.03 | 0.0122 | ICP |
| Ca | % | ≤0.02 | 0.0007 | ICP |
| D10 | µm | ≥1.0 | 1.52 | Laser Particle Size Analyzer |
| D50 | µm | 3.0~5.0 | 3.78 | Laser Particle Size Analyzer |
| D90 | µm | ≤12.0 | 6.62 | Laser Particle Size Analyzer |
| BET | m2/g | 0.9±0.3 | 0.89 | Fully automatic surface area and porosity analyzer |
| TD | g/cm3 | ≥1.5 | 1.78 | Vibrating density measuring instrument |
| pH | / | ≤12.0 | 11.62 | pH value |
| Moisture | ppm | ≤500 | 312 | Moisture meter |
| First discharge capacity | mAh/g | ≥180.0 | 189.6 | CR2032 0.1/0.1C(4.4-2.8V) |
| First discharge efficiency | % | ≥87.0 | 88.7 | CR2032 0.1/0.1C(4.4-2.8V) |
-
Packaging requirements:
Vacuum packaging with aluminum-plastic film, outer layer packaged in plastic bags
Storage requirements: Sealed, stored in a cool and dry place. The material needs to be vacuum sealed for storage. The electrolyte used during testing is NCM electrolyte (KLD-1230C)
Baking conditions for electrode: Bake at 85 ℃ for 4 hours