Properties

Assay Type Competitive-ELISA
Format 96T
Assay time 1.5h
Sample type serum and plasma
Storage 2-8℃
Application This ELISA kit applies to the in vitro determination of in serum or plasma.
Reproducibility Both intra-CV and inter-CV are < 10%.


Test Principle

This ELISA kit uses Indirect-ELISA as the method to qualitatively detect the
Monkeypox Virus (MPXV) IgG in the sample. The micro ELISA plate provided in
this kit is pre- coated with purified MPXV antigen, after adding samples to wells, the
MPXV IgG in the samples will combine with the pre-coated MPXV antigen. After
washing completely, add Horseradish Peroxidase (HRP) conjugated goat anti human
IgG to develop the antigen- antibody-HRP conjugated secondary antibody complex.
Free components are washed away, then the substrate solution is added to each well.
Only those wells that contain MPXV IgG and HRP conjugated anti-human IgG will
appear blue in color. The enzyme- substrate reaction is terminated by the addition of
stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ± 2 nm. Compared with the CUT OFF value to judge whether MPXV IgG exists in the tested samples or not.

Kit Components and Storage

The unopened kit can be stable for 6 months at 2-8℃. After opening the kit, keep
the reagents according to the conditions below.

Item Specifications Storage
Micro ELISA Plate(Dismountable) 96T: 8 wells ×12 strips 2-8℃, 6 months
48T: 8 wells ×6 strips
Positive Control 96T: 2 vials
48T: 1 vial
Negative Control 96T: 2 vials
48T: 1 vial
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL -20℃ (Protect from light), 6 months
48T: 1 vial, 60 μL
Sample & Control Diluent 2 vial, 20 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL
Concentrated Wash Buffer(25×) 1 vial, 30 mL
Stop Solution 1 vial, 10 mL
Substrate Reagent 1 vial, 10 mL 2-8℃(Protect from
light) , 6 months
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Assay Procedures

1. Add 100µL of controls and samples to the appropriate wells. Incubate for 45 min at 37°C.

2. Aspirate and wash the plate for 3 times.

3. Add 100µL of HRP Conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times.

4. Add 90µL of Substrate Reagent. Incubate for about 15 min at 37°C.

5. Add 50µL of Stop Solution.

6. Read the plate at 450nm immediately. Calculation of the results.