Free Fatty Acids (NEFA/FFA) Colorimetric Assay Kit (Enzyme Method)
Couldn't load pickup availability
Consumables Product
This consumable product is not available for refund or return
Still have questions? Ask our experts!
Free Fatty Acids (NEFA/FFA) Colorimetric Assay Kit (Enzyme Method)
| SKU # | E-BC-K792-M |
| Detection Instrument | Microplate reader (540-550 nm, optimum wavelength: 546 nm) |
| Detection Method | Colorimetric method |
Product Details
Properties
| Detection Principle | Free fatty acids (NEFA/FFA) generate acyl-CoA under the action of acyl synthase, then acyl-CoA generates hydrogen peroxide under the oxidation of acyl oxidase. Hydrogen peroxide reacts in the presence of enzymes and chromogens, producing a red substance with maximum absorption at 546 nm. The amount of this red product is proportional to the content of free fatty acids. |
| Sample Type | Serum, Plasma, Animal tissue, Cell |
| Detection Method | Colorimetric method |
| Detection Instrument | Microplate reader (540-550 nm, optimum wavelength: 546 nm) |
| Research Area | Glycolysis And Lipid Metabolism, Metabolic Diseases, Energy Metabolism |
| Other Reagents Required | Normal saline (0.9% NaCl), Double distilled water |
| Storage | This product can be stored at 2-8°C/-20°C for 12 months with shading light. Please refer to the manual for the specific storage condition of the components. |
| Valid Period | 12 months |
| Sensitivity | 0.14 mmol/L |
| Detection Range | 0.14-4 mmol/L |
| Precision | inter-assay CV: 2.5-6.1% | intra-assay CV: 1.5-4.5% |
| Sample Volume | 10 μL |
| Assay Time | 30 min |
Dilution Of Sample
The recommended dilution factor for different samples is as follows (for reference only):
| Sample Type | Dilution Factor |
| Human serum | 1-2 |
| Mouse serum | 4-6 |
| Rat serum | 4-6 |
| Bovine serum | 1-2 |
| 10% Rat liver tissue homogenate | 1-4 |
| 10% Rat heart tissue homogenate | 1-4 |
| 10% Mouse liver tissue homogenate | 1 |
| 3 × 10^6 293T cells | 1 |
The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.
Kit Components & Storage
| Item | Component | Size 1(48 T) | Size 2(96 T) | Storage |
| Reagent 1 | Enzyme Diluent | 12mL x 1 vial | 24mL x 1 vial | 2-8℃, 12 months |
| Reagent 2 | Enzyme Reagent | Powder x 2 vials | Powder x 4 vials | 2-8℃, 12 months |
| Reagent 3 | Chromogenic Agent | 3mL x 1 vial | 6mL x 1 vial | 2-8℃, 12 months |
| Reagent 4 | 1mmol/L Standard | 0.2mL x 1 vial | 0.2mL x 1 vial | 2-8℃, 12 months |
| Microplate | 96 wells | No requirement | ||
| Plate Sealer | 2 pieces | |||
Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.