{"product_id":"neware-wgdw-400l2-40c-380v-12u-b-40-to-150-all-in-one-400l-battery-testing-system","title":"Neware WGDW-400L2-40C-380V-12U-B, -40 to 150℃ All-in-One 400L battery Testing System","description":"\u003ch2 data-section-id=\"1tanyrc\" data-start=\"0\" data-end=\"87\"\u003eNeware WGDW-400L2-40C-380V-12U-B, -40 to 150℃ All-in-One 400L Battery Testing System\u003c\/h2\u003e\n\u003ch3 data-section-id=\"zamd46\" data-start=\"89\" data-end=\"105\"\u003eIntroduction\u003c\/h3\u003e\n\u003cp data-start=\"107\" data-end=\"698\"\u003eThe \u003cstrong data-start=\"111\" data-end=\"199\"\u003eNeware WGDW-400L2-40C-380V-12U-B, -40 to 150℃ All-in-One 400L Battery Testing System\u003c\/strong\u003e is an automatic fire-extinguishing dual-temperature-zone chamber designed for cell performance testing under controlled high- and low-temperature conditions. It combines a 225L × 2 dual-zone chamber with integrated 5V30A64CH (Series 4) testing equipment, making it suitable for new energy production enterprises and research institutes that require reliable environmental and performance testing for battery cells.\u003c\/p\u003e\n\u003cp data-start=\"700\" data-end=\"1243\"\u003eWith a temperature range of -40℃ to 150℃, programmable chamber control, smoke detection, exhaust, fire extinguishing, and insulated multi-layer cell trays, this all-in-one system supports efficient thermal testing and integrated battery test operation. The fire-extinguishing version also adds a safety relief port, safety guard chain, smoke detection, smoke exhaust, and fire extinguishing functions for enhanced protection.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1245\" data-end=\"1261\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1263\" data-end=\"2143\"\u003e\n\u003cli data-section-id=\"qm3fh9\" data-start=\"1263\" data-end=\"1315\"\u003eAll-in-one dual-zone battery cell testing system\u003c\/li\u003e\n\u003cli data-section-id=\"165kbnw\" data-start=\"1316\" data-end=\"1364\"\u003eProduct model: WGDW-400L2-40C-380V-12U-B\u003c\/li\u003e\n\u003cli data-section-id=\"fzktwn\" data-start=\"1365\" data-end=\"1404\"\u003eTemperature range: -40℃ to 150℃\u003c\/li\u003e\n\u003cli data-section-id=\"hnaq23\" data-start=\"1405\" data-end=\"1464\"\u003eDual temperature zones, nominal volume 225L × 2\u003c\/li\u003e\n\u003cli data-section-id=\"zm99ut\" data-start=\"1465\" data-end=\"1522\"\u003eIntegrated 5V30A64CH (Series 4) testing equipment\u003c\/li\u003e\n\u003cli data-section-id=\"12l9766\" data-start=\"1523\" data-end=\"1595\"\u003eAutomatic fire extinguishing design with smoke detection and exhaust\u003c\/li\u003e\n\u003cli data-section-id=\"1sf2eat\" data-start=\"1596\" data-end=\"1638\"\u003eHigh color LCD touch screen controller\u003c\/li\u003e\n\u003cli data-section-id=\"1okuyrv\" data-start=\"1639\" data-end=\"1684\"\u003eProgram mode and set value mode operation\u003c\/li\u003e\n\u003cli data-section-id=\"1xlgim6\" data-start=\"1685\" data-end=\"1745\"\u003ePT100 temperature sensor with 0.01℃ display accuracy\u003c\/li\u003e\n\u003cli data-section-id=\"157ayi\" data-start=\"1746\" data-end=\"1789\"\u003eHeating time: +20℃ to +150℃ ≤60 min\u003c\/li\u003e\n\u003cli data-section-id=\"1syy86z\" data-start=\"1790\" data-end=\"1832\"\u003eCooling time: +20℃ to -40℃ ≤60 min\u003c\/li\u003e\n\u003cli data-section-id=\"1ovrncg\" data-start=\"1833\" data-end=\"1900\"\u003eAnti-fog observation window, lighting, and insulated cell trays\u003c\/li\u003e\n\u003cli data-section-id=\"9gx4qd\" data-start=\"1901\" data-end=\"1975\"\u003eSupports upper computer programming control and Ethernet communication\u003c\/li\u003e\n\u003cli data-section-id=\"5zzp7e\" data-start=\"1976\" data-end=\"2143\"\u003eSuitable for cylindrical cell performance testing in research and production environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"2145\" data-end=\"2163\"\u003eSpecifications\u003c\/h3\u003e\n\u003ch4 data-start=\"2165\" data-end=\"2179\"\u003eDatasheet\u003c\/h4\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2181\" data-end=\"7026\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2181\" data-end=\"2210\"\u003e\n\u003ctr data-start=\"2181\" data-end=\"2210\"\u003e\n\u003cth data-start=\"2181\" data-end=\"2193\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2193\" data-end=\"2210\" data-col-size=\"lg\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2221\" data-end=\"7026\"\u003e\n\u003ctr data-start=\"2326\" data-end=\"2371\"\u003e\n\u003ctd data-start=\"2326\" data-end=\"2342\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2342\" data-end=\"2371\" data-col-size=\"lg\"\u003eWGDW-400L2-40C-380V-12U-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2372\" data-end=\"2475\"\u003e\n\u003ctd data-start=\"2372\" data-end=\"2387\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2387\" data-end=\"2475\" data-col-size=\"lg\"\u003eAutomatic Fire Extinguishing Dual-Temperature Zones High and Low Temperature Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2476\" data-end=\"2637\"\u003e\n\u003ctd data-start=\"2476\" data-end=\"2490\" data-col-size=\"sm\"\u003eInstruction\u003c\/td\u003e\n\u003ctd data-start=\"2490\" data-end=\"2637\" data-col-size=\"lg\"\u003eAutomatic fire extinguishing type adds safety relief port, safety guard chain, smoke detection, smoke exhaust, and fire extinguishing functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2638\" data-end=\"2742\"\u003e\n\u003ctd data-start=\"2638\" data-end=\"2652\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2652\" data-end=\"2742\" data-col-size=\"lg\"\u003eCell performance testing for new energy production enterprises and research institutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2743\" data-end=\"2772\"\u003e\n\u003ctd data-start=\"2743\" data-end=\"2760\" data-col-size=\"sm\"\u003eNominal Volume\u003c\/td\u003e\n\u003ctd data-start=\"2760\" data-end=\"2772\" data-col-size=\"lg\"\u003e225L × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2773\" data-end=\"2841\"\u003e\n\u003ctd data-start=\"2773\" data-end=\"2816\" data-col-size=\"sm\"\u003eInner Box Size (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-start=\"2816\" data-end=\"2841\" data-col-size=\"lg\"\u003eW600 × D500 × H750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2842\" data-end=\"2892\"\u003e\n\u003ctd data-start=\"2842\" data-end=\"2864\" data-col-size=\"sm\"\u003eExternal Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2864\" data-end=\"2892\" data-col-size=\"lg\"\u003eW1110 × D1800 × H2050 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2893\" data-end=\"2918\"\u003e\n\u003ctd data-start=\"2893\" data-end=\"2902\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2902\" data-end=\"2918\" data-col-size=\"lg\"\u003eAbout 720 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2919\" data-end=\"2955\"\u003e\n\u003ctd data-start=\"2919\" data-end=\"2939\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2939\" data-end=\"2955\" data-col-size=\"lg\"\u003e-40℃ to 150℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2956\" data-end=\"3022\"\u003e\n\u003ctd data-start=\"2956\" data-end=\"2982\" data-col-size=\"sm\"\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd data-start=\"2982\" data-end=\"3022\" data-col-size=\"lg\"\u003e≤±0.5℃ (no load, temperature stable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3023\" data-end=\"3086\"\u003e\n\u003ctd data-start=\"3023\" data-end=\"3047\" data-col-size=\"sm\"\u003eTemperature Deviation\u003c\/td\u003e\n\u003ctd data-start=\"3047\" data-end=\"3086\" data-col-size=\"lg\"\u003e±2.0℃ (no load, temperature stable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3087\" data-end=\"3127\"\u003e\n\u003ctd data-start=\"3087\" data-end=\"3102\" data-col-size=\"sm\"\u003eHeating Time\u003c\/td\u003e\n\u003ctd data-start=\"3102\" data-end=\"3127\" data-col-size=\"lg\"\u003e+20℃ to +150℃ ≤60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3128\" data-end=\"3167\"\u003e\n\u003ctd data-start=\"3128\" data-end=\"3143\" data-col-size=\"sm\"\u003eCooling Time\u003c\/td\u003e\n\u003ctd data-start=\"3143\" data-end=\"3167\" data-col-size=\"lg\"\u003e+20℃ to -40℃ ≤60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3168\" data-end=\"3229\"\u003e\n\u003ctd data-start=\"3168\" data-end=\"3182\" data-col-size=\"sm\"\u003eTest Method\u003c\/td\u003e\n\u003ctd data-start=\"3182\" data-end=\"3229\" data-col-size=\"lg\"\u003eGB\/T 5170.2-2017 Temperature test equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3230\" data-end=\"3335\"\u003e\n\u003ctd data-start=\"3230\" data-end=\"3246\" data-col-size=\"sm\"\u003eStandards Met\u003c\/td\u003e\n\u003ctd data-start=\"3246\" data-end=\"3335\" data-col-size=\"lg\"\u003eGB\/T 2423.1-2008, GB\/T 2423.2-2008, GJB 150.3A-2009, GJB 150.4A-2009, GB\/T 10592-2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3336\" data-end=\"3426\"\u003e\n\u003ctd data-start=\"3336\" data-end=\"3361\" data-col-size=\"sm\"\u003eExterior Wall Material\u003c\/td\u003e\n\u003ctd data-start=\"3361\" data-end=\"3426\" data-col-size=\"lg\"\u003eHigh quality cold rolled steel plate, surface spray treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3427\" data-end=\"3481\"\u003e\n\u003ctd data-start=\"3427\" data-end=\"3449\" data-col-size=\"sm\"\u003eInner Wall Material\u003c\/td\u003e\n\u003ctd data-start=\"3449\" data-end=\"3481\" data-col-size=\"lg\"\u003eSUS304 stainless steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3482\" data-end=\"3557\"\u003e\n\u003ctd data-start=\"3482\" data-end=\"3504\" data-col-size=\"sm\"\u003eInsulation Material\u003c\/td\u003e\n\u003ctd data-start=\"3504\" data-end=\"3557\" data-col-size=\"lg\"\u003eHard polyurethane foam + aluminum silicate cotton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3558\" data-end=\"3591\"\u003e\n\u003ctd data-start=\"3558\" data-end=\"3581\" data-col-size=\"sm\"\u003eInsulation Thickness\u003c\/td\u003e\n\u003ctd data-start=\"3581\" data-end=\"3591\" data-col-size=\"lg\"\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3592\" data-end=\"3717\"\u003e\n\u003ctd data-start=\"3592\" data-end=\"3619\" data-col-size=\"sm\"\u003eAir Conditioning Channel\u003c\/td\u003e\n\u003ctd data-start=\"3619\" data-end=\"3717\" data-col-size=\"lg\"\u003eCentrifugal fan, heater, evaporator (also dehumidifier), C-type air supply and return air mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3718\" data-end=\"3770\"\u003e\n\u003ctd data-start=\"3718\" data-end=\"3756\" data-col-size=\"sm\"\u003eLead Hole (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-start=\"3756\" data-end=\"3770\" data-col-size=\"lg\"\u003eφ50 mm \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3771\" data-end=\"3807\"\u003e\n\u003ctd data-start=\"3771\" data-end=\"3780\" data-col-size=\"sm\"\u003eWheels\u003c\/td\u003e\n\u003ctd data-start=\"3780\" data-end=\"3807\" data-col-size=\"lg\"\u003e4, with adjustable feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3808\" data-end=\"3930\"\u003e\n\u003ctd data-start=\"3808\" data-end=\"3829\" data-col-size=\"sm\"\u003eObservation Window\u003c\/td\u003e\n\u003ctd data-start=\"3829\" data-end=\"3930\" data-col-size=\"lg\"\u003eMulti-layer hollow electric heating anti-fog observation window, about 330 × 450 mm visible range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3931\" data-end=\"3973\"\u003e\n\u003ctd data-start=\"3931\" data-end=\"3968\" data-col-size=\"sm\"\u003eLighting (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-start=\"3968\" data-end=\"3973\" data-col-size=\"lg\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3974\" data-end=\"4077\"\u003e\n\u003ctd data-start=\"3974\" data-end=\"4012\" data-col-size=\"sm\"\u003eCell Tray (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-start=\"4012\" data-end=\"4077\" data-col-size=\"lg\"\u003e2 layers, high-temperature resistant electric insulation tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4078\" data-end=\"4133\"\u003e\n\u003ctd data-start=\"4078\" data-end=\"4099\" data-col-size=\"sm\"\u003eTray Load Capacity\u003c\/td\u003e\n\u003ctd data-start=\"4099\" data-end=\"4133\" data-col-size=\"lg\"\u003e20 kg\/layer evenly distributed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4134\" data-end=\"4179\"\u003e\n\u003ctd data-start=\"4134\" data-end=\"4170\" data-col-size=\"sm\"\u003eMaximum Total Sample Load per Box\u003c\/td\u003e\n\u003ctd data-start=\"4170\" data-end=\"4179\" data-col-size=\"lg\"\u003e80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4180\" data-end=\"4239\"\u003e\n\u003ctd data-start=\"4180\" data-end=\"4192\" data-col-size=\"sm\"\u003eDoor Type\u003c\/td\u003e\n\u003ctd data-start=\"4192\" data-end=\"4239\" data-col-size=\"lg\"\u003eSingle hinge door, left hinge, right handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4240\" data-end=\"4383\"\u003e\n\u003ctd data-start=\"4240\" data-end=\"4256\" data-col-size=\"sm\"\u003eDoor Features\u003c\/td\u003e\n\u003ctd data-start=\"4256\" data-end=\"4383\" data-col-size=\"lg\"\u003eObservation window, lighting lamp, anti-condensation heating, double-layer silicone sealing strip, safety protection chains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4384\" data-end=\"4458\"\u003e\n\u003ctd data-start=\"4384\" data-end=\"4400\" data-col-size=\"sm\"\u003eControl Panel\u003c\/td\u003e\n\u003ctd data-start=\"4400\" data-end=\"4458\" data-col-size=\"lg\"\u003eController display, over-temperature protection setter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4459\" data-end=\"4543\"\u003e\n\u003ctd data-start=\"4459\" data-end=\"4488\" data-col-size=\"sm\"\u003eRefrigeration Working Mode\u003c\/td\u003e\n\u003ctd data-start=\"4488\" data-end=\"4543\" data-col-size=\"lg\"\u003eMechanical compression cascade refrigeration method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4544\" data-end=\"4660\"\u003e\n\u003ctd data-start=\"4544\" data-end=\"4571\" data-col-size=\"sm\"\u003eRefrigeration Compressor\u003c\/td\u003e\n\u003ctd data-start=\"4571\" data-end=\"4660\" data-col-size=\"lg\"\u003eFrance imported “Taikang” fully enclosed compressor or Emerson gas turbine compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4661\" data-end=\"4797\"\u003e\n\u003ctd data-start=\"4661\" data-end=\"4693\" data-col-size=\"sm\"\u003eMain Refrigeration Components\u003c\/td\u003e\n\u003ctd data-start=\"4693\" data-end=\"4797\" data-col-size=\"lg\"\u003eThrottle valve, pressure controller, drying filter, cooling solenoid valve, reservoir, oil separator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4798\" data-end=\"4841\"\u003e\n\u003ctd data-start=\"4798\" data-end=\"4811\" data-col-size=\"sm\"\u003eEvaporator\u003c\/td\u003e\n\u003ctd data-start=\"4811\" data-end=\"4841\" data-col-size=\"lg\"\u003eFinned tube heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4842\" data-end=\"4895\"\u003e\n\u003ctd data-start=\"4842\" data-end=\"4854\" data-col-size=\"sm\"\u003eCondenser\u003c\/td\u003e\n\u003ctd data-start=\"4854\" data-end=\"4895\" data-col-size=\"lg\"\u003eAir-cooled finned tube heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4896\" data-end=\"4949\"\u003e\n\u003ctd data-start=\"4896\" data-end=\"4914\" data-col-size=\"sm\"\u003eThrottle Device\u003c\/td\u003e\n\u003ctd data-start=\"4914\" data-end=\"4949\" data-col-size=\"lg\"\u003eThrottle valve \/ capillary tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4950\" data-end=\"4979\"\u003e\n\u003ctd data-start=\"4950\" data-end=\"4964\" data-col-size=\"sm\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd data-start=\"4964\" data-end=\"4979\" data-col-size=\"lg\"\u003eR404A \/ R23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4980\" data-end=\"5027\"\u003e\n\u003ctd data-start=\"4980\" data-end=\"4994\" data-col-size=\"sm\"\u003eHeater Type\u003c\/td\u003e\n\u003ctd data-start=\"4994\" data-end=\"5027\" data-col-size=\"lg\"\u003eStainless steel finned heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5028\" data-end=\"5102\"\u003e\n\u003ctd data-start=\"5028\" data-end=\"5050\" data-col-size=\"sm\"\u003eHeater Control Mode\u003c\/td\u003e\n\u003ctd data-start=\"5050\" data-end=\"5102\" data-col-size=\"lg\"\u003eContactless periodic pulse width modulation, SSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5103\" data-end=\"5161\"\u003e\n\u003ctd data-start=\"5103\" data-end=\"5122\" data-col-size=\"sm\"\u003eController Model\u003c\/td\u003e\n\u003ctd data-start=\"5122\" data-end=\"5161\" data-col-size=\"lg\"\u003eProfessional temperature controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5162\" data-end=\"5203\"\u003e\n\u003ctd data-start=\"5162\" data-end=\"5172\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"5172\" data-end=\"5203\" data-col-size=\"lg\"\u003eHigh color LCD touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5204\" data-end=\"5253\"\u003e\n\u003ctd data-start=\"5204\" data-end=\"5221\" data-col-size=\"sm\"\u003eOperation Mode\u003c\/td\u003e\n\u003ctd data-start=\"5221\" data-end=\"5253\" data-col-size=\"lg\"\u003eProgram mode, set value mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5254\" data-end=\"5340\"\u003e\n\u003ctd data-start=\"5254\" data-end=\"5271\" data-col-size=\"sm\"\u003eSetting Method\u003c\/td\u003e\n\u003ctd data-start=\"5271\" data-end=\"5340\" data-col-size=\"lg\"\u003eColor touch human-computer interaction, Chinese\/English interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5341\" data-end=\"5426\"\u003e\n\u003ctd data-start=\"5341\" data-end=\"5356\" data-col-size=\"sm\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd data-start=\"5356\" data-end=\"5426\" data-col-size=\"lg\"\u003eAnti-integral saturation PID, BTC balance temperature control mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5427\" data-end=\"5492\"\u003e\n\u003ctd data-start=\"5427\" data-end=\"5460\" data-col-size=\"sm\"\u003eTemperature Measurement Method\u003c\/td\u003e\n\u003ctd data-start=\"5460\" data-end=\"5492\" data-col-size=\"lg\"\u003eGrade A armored PT100 sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5493\" data-end=\"5547\"\u003e\n\u003ctd data-start=\"5493\" data-end=\"5512\" data-col-size=\"sm\"\u003eDisplay Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"5512\" data-end=\"5547\" data-col-size=\"lg\"\u003eTemperature: 0.01℃; Time: 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5548\" data-end=\"5639\"\u003e\n\u003ctd data-start=\"5548\" data-end=\"5578\" data-col-size=\"sm\"\u003eOver-Temperature Protection\u003c\/td\u003e\n\u003ctd data-start=\"5578\" data-end=\"5639\" data-col-size=\"lg\"\u003eIndependent overtemperature protector with shutdown alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5640\" data-end=\"5731\"\u003e\n\u003ctd data-start=\"5640\" data-end=\"5671\" data-col-size=\"sm\"\u003eIntegrated Testing Equipment\u003c\/td\u003e\n\u003ctd data-start=\"5671\" data-end=\"5731\" data-col-size=\"lg\"\u003e5V30A64CH (Series 4), located on the side of the housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5732\" data-end=\"5752\"\u003e\n\u003ctd data-start=\"5732\" data-end=\"5747\" data-col-size=\"sm\"\u003eControl Unit\u003c\/td\u003e\n\u003ctd data-start=\"5747\" data-end=\"5752\" data-col-size=\"lg\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5753\" data-end=\"5775\"\u003e\n\u003ctd data-start=\"5753\" data-end=\"5770\" data-col-size=\"sm\"\u003eNetwork Switch\u003c\/td\u003e\n\u003ctd data-start=\"5770\" data-end=\"5775\" data-col-size=\"lg\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5776\" data-end=\"5846\"\u003e\n\u003ctd data-start=\"5776\" data-end=\"5798\" data-col-size=\"sm\"\u003eProgramming Control\u003c\/td\u003e\n\u003ctd data-start=\"5798\" data-end=\"5846\" data-col-size=\"lg\"\u003eUpper computer programming control supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5847\" data-end=\"5946\"\u003e\n\u003ctd data-start=\"5847\" data-end=\"5874\" data-col-size=\"sm\"\u003eRefrigeration Protection\u003c\/td\u003e\n\u003ctd data-start=\"5874\" data-end=\"5946\" data-col-size=\"lg\"\u003eCompressor overheating, compressor overload, compressor overpressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5947\" data-end=\"6072\"\u003e\n\u003ctd data-start=\"5947\" data-end=\"5973\" data-col-size=\"sm\"\u003eTest Chamber Protection\u003c\/td\u003e\n\u003ctd data-start=\"5973\" data-end=\"6072\" data-col-size=\"lg\"\u003eAdjustable overtemperature protection and abnormal protection of the circulating fan in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6073\" data-end=\"6099\"\u003e\n\u003ctd data-start=\"6073\" data-end=\"6087\" data-col-size=\"sm\"\u003eSmoke Alarm\u003c\/td\u003e\n\u003ctd data-start=\"6087\" data-end=\"6099\" data-col-size=\"lg\"\u003eEquipped\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6100\" data-end=\"6174\"\u003e\n\u003ctd data-start=\"6100\" data-end=\"6117\" data-col-size=\"sm\"\u003eExhaust Device\u003c\/td\u003e\n\u003ctd data-start=\"6117\" data-end=\"6174\" data-col-size=\"lg\"\u003eAuto starts when smoke concentration exceeds standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6175\" data-end=\"6287\"\u003e\n\u003ctd data-start=\"6175\" data-end=\"6203\" data-col-size=\"sm\"\u003eFire Extinguishing Device\u003c\/td\u003e\n\u003ctd data-start=\"6203\" data-end=\"6287\" data-col-size=\"lg\"\u003eOne 8L carbon dioxide empty bottle per device, manual or automatic extinguishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6288\" data-end=\"6450\"\u003e\n\u003ctd data-start=\"6288\" data-end=\"6315\" data-col-size=\"sm\"\u003eOther Safety Protections\u003c\/td\u003e\n\u003ctd data-start=\"6315\" data-end=\"6450\" data-col-size=\"lg\"\u003ePhase sequence and phase loss protection, leakage protection, overload, short circuit protection, power failure recovery protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6451\" data-end=\"6537\"\u003e\n\u003ctd data-start=\"6451\" data-end=\"6477\" data-col-size=\"sm\"\u003ePower Supply Conditions\u003c\/td\u003e\n\u003ctd data-start=\"6477\" data-end=\"6537\" data-col-size=\"lg\"\u003eAC (380±38) V, (50±0.5) Hz, three-phase five-wire system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6538\" data-end=\"6569\"\u003e\n\u003ctd data-start=\"6538\" data-end=\"6561\" data-col-size=\"sm\"\u003eGrounding Resistance\u003c\/td\u003e\n\u003ctd data-start=\"6561\" data-end=\"6569\" data-col-size=\"lg\"\u003e\u0026lt; 4Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6570\" data-end=\"6643\"\u003e\n\u003ctd data-start=\"6570\" data-end=\"6591\" data-col-size=\"sm\"\u003ePower Distribution\u003c\/td\u003e\n\u003ctd data-start=\"6591\" data-end=\"6643\" data-col-size=\"lg\"\u003e(7 kW temperature box + 6 kW test equipment) × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6644\" data-end=\"6674\"\u003e\n\u003ctd data-start=\"6644\" data-end=\"6662\" data-col-size=\"sm\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd data-start=\"6662\" data-end=\"6674\" data-col-size=\"lg\"\u003e26 A × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6675\" data-end=\"6735\"\u003e\n\u003ctd data-start=\"6675\" data-end=\"6699\" data-col-size=\"sm\"\u003eOperating Environment\u003c\/td\u003e\n\u003ctd data-start=\"6699\" data-end=\"6735\" data-col-size=\"lg\"\u003e5℃ to 35℃, ≤85% RH, 86kPa–106kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6736\" data-end=\"6843\"\u003e\n\u003ctd data-start=\"6736\" data-end=\"6757\" data-col-size=\"sm\"\u003eCell Specification\u003c\/td\u003e\n\u003ctd data-start=\"6757\" data-end=\"6843\" data-col-size=\"lg\"\u003eCylindrical cell, single temperature zone 5V30A32CH (double temperature zone 64CH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6844\" data-end=\"6959\"\u003e\n\u003ctd data-start=\"6844\" data-end=\"6868\" data-col-size=\"sm\"\u003eCell Placement Method\u003c\/td\u003e\n\u003ctd data-start=\"6868\" data-end=\"6959\" data-col-size=\"lg\"\u003eFour floors in the single temperature zone, eight floors in the double temperature zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6960\" data-end=\"7026\"\u003e\n\u003ctd data-start=\"6960\" data-end=\"6986\" data-col-size=\"sm\"\u003eCell Tray Customization\u003c\/td\u003e\n\u003ctd data-start=\"6986\" data-end=\"7026\" data-col-size=\"lg\"\u003eCan be customized according to needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"7028\" data-end=\"7103\"\u003e \u003c\/p\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"7105\" data-end=\"7121\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"7123\" data-end=\"7178\"\u003eThis all-in-one battery testing system is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"7180\" data-end=\"7630\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1c06lh4\" data-start=\"7180\" data-end=\"7258\"\u003eBattery cell performance testing under high and low temperature conditions\u003c\/li\u003e\n\u003cli data-section-id=\"m47fk4\" data-start=\"7259\" data-end=\"7325\"\u003eCylindrical cell testing in new energy production environments\u003c\/li\u003e\n\u003cli data-section-id=\"in8oy6\" data-start=\"7326\" data-end=\"7396\"\u003eResearch institute battery validation and environmental simulation\u003c\/li\u003e\n\u003cli data-section-id=\"1608wog\" data-start=\"7397\" data-end=\"7459\"\u003eIntegrated thermal chamber and battery cell test workflows\u003c\/li\u003e\n\u003cli data-section-id=\"1t2z8oa\" data-start=\"7460\" data-end=\"7630\" data-is-last-node=\"\"\u003eSafety-focused cell testing with smoke detection, exhaust, and fire extinguishing features\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Neware","offers":[{"title":"Default Title","offer_id":41360274260026,"sku":"WGDW-400L2-40C-380V-12U-B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/WGDW-800L2-20C-380V-32U-B_067b92f4-c101-43db-ad9c-825508b56589.jpg?v=1777055911","url":"https:\/\/www.msesupplies.com\/products\/neware-wgdw-400l2-40c-380v-12u-b-40-to-150-all-in-one-400l-battery-testing-system","provider":"MSE Supplies","version":"1.0","type":"link"}