{"product_id":"mse-pro-type-2-deionized-water-purifier-edi","title":"MSE PRO Type 2 Deionized Water Purifier (EDI)","description":"\u003ch2\u003eMSE PRO™ Type 2 Deionized Water Purifier (EDI)\u003c\/h2\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColored touched screen, humanized operation interface makes users completely monitor controller’s working status and real-time data.\u003c\/li\u003e\n\u003cli\u003eLifetime of PP cotton, activated carbon filter, RO membrane and ultra purification columns can be set to display the elapsed \u0026amp; rest time of consumables. Automatic reminder for filter replacement to avoid water quality decreasing.\u003c\/li\u003e\n\u003cli\u003eThe pipeline adopts a quick-plug interface, the pipe joint passes NSF certification.\u003c\/li\u003e\n\u003cli\u003eInbuilt feed water pressure test gauge to real time monitor tap water pressure and filters blocking.\u003c\/li\u003e\n\u003cli\u003ePerfect managing functions of DI water making circulation system and sterilization.\u003c\/li\u003e\n\u003cli\u003eThe machine is equipped with pure water transfer pump to ensure the flow rate of water.\u003c\/li\u003e\n\u003cli\u003eABS engineering plastic case, powder coating technology, with water quality and quantity upgrading function, door is open at the side.\u003c\/li\u003e\n\u003cli\u003eBacklight LCD display, dual waterway online monitoring, which can simultaneously display DI resistance value and equipment operating status indication. Alarming for water quality exceeding, automatic filters replacement reminding, water intake time can be set.\u003c\/li\u003e\n\u003cli\u003eMenu-type operation, parameters can be set and modified, operating status display and indication light indicate to promptly reflect machine operating status such as high-pressure shutdown, low-pressure alarm, water full shutdown, etc.\u003c\/li\u003e\n\u003cli\u003eEquipped with a portable test pen, which can test TDS content, conductance and water temperature anytime, anywhere\u003c\/li\u003e\n\u003cli\u003eWith RS-232C communication interface output, it can be connected with intelligent instruments with RS-232C interface to realize the transmission of measurement data or print records\u003c\/li\u003e\n\u003cli\u003eUsing EDI module, Ensure the purity of water and maintain the life of consumables.\u003c\/li\u003e\n\u003cli\u003e40 L water level tank to store EDI water \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParameters: \u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 497pt;\" width=\"662\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5585; width: 120pt;\" width=\"160\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 17524; width: 377pt;\" width=\"502\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; width: 120pt;\" width=\"160\" class=\"xl65\" height=\"19\"\u003eWater rate\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 377pt;\" width=\"502\" class=\"xl66\"\u003e90 Liter per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none;\" class=\"xl65\" height=\"19\"\u003eThe water requirements\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none;\" class=\"xl66\"\u003eUrban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt;\" class=\"xl67\" height=\"19\" colspan=\"2\"\u003eRO water Parameter(ASTM TYPE III grade water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eConductivity\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e1-5 us\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.0pt;\" height=\"77\"\u003e\n\u003ctd style=\"height: 58.0pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"77\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u003cspan lang=\"EN\"\u003eFront system of ultra-pure water machine, buffer configuration, photosensitive film washing, water supply for stability experiment box, meteorological experiment equipment, hydrogen generator, battery adding liquid, electroplating and other instruments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 33.5pt;\" height=\"45\"\u003e\n\u003ctd style=\"height: 33.5pt; width: 497pt;\" width=\"662\" class=\"xl70\" height=\"45\" colspan=\"2\"\u003eDI water Parameter(ASTM TYPE II grade water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eResistivity (25℃)\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e10-16 M Ω. cm @ 25 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eConductivity\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;0.1 \u003cspan class=\"font6\"\u003eμ\u003c\/span\u003e\u003cspan class=\"font5\"\u003eS\/cm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eIonic rejection\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e95-99 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.0pt;\" height=\"39\"\u003e\n\u003ctd style=\"height: 29.0pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"39\"\u003eOrganic Rejection (\u0026gt; 200 Dalton MW)\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl71\"\u003e\u003cspan lang=\"ZH-CN\"\u003e≥\u003cspan class=\"font5\"\u003e99 %\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eParticle rejection\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl71\"\u003e\u003cspan lang=\"ZH-CN\"\u003e≥\u003cspan class=\"font5\"\u003e99 %\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eChloride Ion\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;5 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eSulfate Ion\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eNitrate Ion\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;200 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eBacteria\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;10 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eSilica rejection\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026gt;99.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eZinc Ion\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;0.1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eSodium Ion\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e\u0026lt;5 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 72.5pt;\" height=\"97\"\u003e\n\u003ctd style=\"height: 72.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"97\"\u003eApplication\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003ePreposition unit of ultra pure water system, supply water for biochemical analyzer, electroplating painting, battery charging, chips washing, microbial culture media, chemical\u0026amp;biochemical regent preparation, buffer making, photographic film processing, stability test chamber, meteorological test equipment, hydrogen generator, salt spray test chamber.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.5pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.5pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"19\"\u003eElectrical requirements\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003e100-240V, 50\/60Hz, 48-72W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.0pt;\" height=\"39\"\u003e\n\u003ctd style=\"height: 29.0pt; border-top: none; width: 120pt;\" width=\"160\" class=\"xl68\" height=\"39\"\u003eThe system configuration\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 377pt;\" width=\"502\" class=\"xl69\"\u003eHost machine (including 1 set of purification column) +TDS pen + accessory bag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MSE Supplies","offers":[{"title":"Default Title","offer_id":41012781121594,"sku":"MA1189","price":11000.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MSEPROType2DeionizedWaterPurifier_EDI.jpg?v=1758038786","url":"https:\/\/www.msesupplies.com\/products\/mse-pro-type-2-deionized-water-purifier-edi","provider":"MSE Supplies","version":"1.0","type":"link"}