{"product_id":"gasera-one-tetrafluoromethane-gas-analyzer","title":"Gasera One CF4 (Tetrafluoromethane) Gas Analyzer","description":"\u003ch2\u003eGasera One CF4 (Tetrafluoromethane) Gas Analyzer\u003c\/h2\u003e\n\u003cp\u003eMSE Supplies is an authorized distributor of Gasera Products in the US. \u003cstrong\u003e\u003cem\u003ePlease\u003cspan\u003e fill out the application questionnaire and \u003c\/span\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e\u003cspan\u003e to discuss the application and configurations.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eIntroduction\u003c\/h3\u003e\n\u003cp\u003eCleanrooms must be controlled for contamination levels. Accurate, reliable and low maintenance control of cleanroom airborne contamination enables significant yield improvements.\u003c\/p\u003e\n\u003cp\u003eHigh sensitivity of the GASERA ONE CF4 enables fast response time for detecting contamination of the production environment. Furthermore, the direct absorption measurement provides extremely good long-term stability due to its zero-background nature. The GASERA ONE CF4 can be integrated into a cabinet along with other instrumentation such as particle monitors.\u003c\/p\u003e\n\u003cp\u003eGASERA ONE CF4 analyzer is based on combining ultra sensitive cantilever enhanced photoacoustic detection technology with Quantum Cascade Laser source operating at a Mid-IR fundamental spectral absorption line of CF4. This combination provides enough sensitivity to reliably detect the smallest spills of CF4 without any delay. It also gives an exceptionally high level of stability with a re-calibration period ranging from several\u003cbr\u003emonths up to several years, and thus it offers a low total cost of ownership.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, reliable and low maintenance control of cleanroom contamination\u003c\/li\u003e\n\u003cli\u003eselective trace level monitoring of CF4\u003c\/li\u003e\n\u003cli\u003eHighly selective against aldehydes and other VOCs\u003c\/li\u003e\n\u003cli\u003eBelow 0.1 ppb limit detection\u003c\/li\u003e\n\u003cli\u003eResponse time user configurable from 10 seconds to few minutes\u003c\/li\u003e\n\u003cli\u003eWide dynamic range and stable operation\u003c\/li\u003e\n\u003cli\u003eRequires no consumables\u003c\/li\u003e\n\u003cli\u003eLow sample volume (few ml)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRecommended re-calibration interval of 12 months\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser configurable monitoring tasks\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in display presents results both numerically and graphically\u003c\/li\u003e\n\u003cli\u003eRemote operation via local network\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Performance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDetection Limit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 0.1ppb \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResponse Time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e dependent on user configurable channel integration time (C.I.T.) and gas exchange routine. From approx. 10 seconds to few minutes depending on averaging time and sampling details.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDynamic Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e over 5 orders of magnitude (i.e. 100 000 times the detection limit)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRepeatability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 1% of measured value in operational conditions at the calibration concentration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Better than 5% at the calibration concentration. Limited by the calibration gas accuracy\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No drift due to ambient temperature or pressure variations within recommended working conditions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eSystem Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eForm Factor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19” 3U rack-mount \/ tabletop unit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48.4 × 13.9 × 44 cm (19.1 × 5.5 × 17.3 in)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ~13 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDisplay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in computer with 7” WSVGA screen\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInternal Gas Volume:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30 ml\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eData Storage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥ 1 year continuous monitoring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eOperating Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTemperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0°C to +49°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHumidity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 750–1050 mbar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDust\/water resistance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20 (IEC 529)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSample Gas Conditions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTemperature: 0°C to +49°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHumidity: Up to 99% RH (non-condensing, temperature dependent)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow Rate: ~1 L\/min\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParticle Size: \u0026lt; 1 µm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eElectrical \u0026amp; Interfaces\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInput Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 90–264 VAC, 47–63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Max. 75 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInterfaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ethernet, USB, optional Serial\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProtocols:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e MODBUS, AK protocol\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Current or voltage signal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eCompliance \u0026amp; Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLow Voltage Directive 2014\/35\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEMC Directive 2004\/108\/EC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS 2 Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAirborne molecular contamination (AMC) in semiconductor cleanrooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated publications:\u003c\/h3\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-luminous-fast-follows enable-updated-hr-color\" id=\"model-response-message-contentr_80a9cd2cf4452c38\" dir=\"ltr\"\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/FastSensorDifferentialPhotoacoustic_TeMe_2012_0173.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eSensitive and fast gas sensor for wide variety of applications based on novel differential infrared photoacoustic principle (2012) – Results from MINIGAS and GHG Flux -projects\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/PAS_GasAnalysisWithCantileverMicrophone_ApplSpectrosRew_2007.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eApplied Spectroscopy Reviews (2007): Photoacoustic Gas Analysis Using Interferometric Cantilever Microphone\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp\u003eIf you are interested in other gas types or multi-gas analyzers, please \u003cstrong\u003e\u003cem\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e \u003c\/em\u003e\u003c\/strong\u003eabout your application: \u003c\/p\u003e\n\u003cp\u003e• Formaldehyde\u003cbr\u003e• Greenhouse gases\u003cbr\u003e• HF, HCl, HCN, SO2, NO2, EtO\u003cbr\u003e• SF6, NOVEC\u003cbr\u003e• CF4, PFCs\u003cbr\u003e• Benzene\u003cbr\u003e• Many more!\u003c\/p\u003e","brand":"Gasera","offers":[{"title":"Default Title","offer_id":41461840085050,"sku":"GASERA ONE CF4","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/gaseraoneCF4_0.png?v=1781815417","url":"https:\/\/www.msesupplies.com\/products\/gasera-one-tetrafluoromethane-gas-analyzer","provider":"MSE Supplies","version":"1.0","type":"link"}