{"product_id":"gasera-one-greenhouse-gas-analyzer","title":"Gasera One GHG (Greenhouse Gas) Analyzer","description":"\u003ch2\u003eGasera One GHG (Greenhouse Gas) Analyzer\u003c\/h2\u003e\n\u003cp\u003eMSE Supplies is an authorized distributor of Gasera Products in the US. \u003cstrong\u003e\u003cem\u003ePlease\u003cspan\u003e fill out the application questionnaire and \u003c\/span\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e\u003cspan\u003e to discuss the application and configurations.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eIntroduction\u003c\/h3\u003e\n\u003cp\u003eThe monitoring and reporting of greenhouse gas emissions is the basis for the global climate policy. A large amount of greenhouse gases released to the atmosphere is due to human activities such as farming. Emissions take place from the livestock and from soil and are a concern for both the environment and for the efficiency of food production. Monitoring of greenhouse gases can also be used to improve the living conditions of farm animals and to evaluate the need for fertilization of the soil and soil applications in general.\u003c\/p\u003e\n\u003cp\u003eGASERA ONE GHG analyzer is based on combining ultra sensitive cantilever enhanced photoacoustic detection technology with Quantum Cascade Laser (QCL) source operating at a Mid-IR fundamental spectral absorption lines of CH4 and N2O. This combination provides an exceptionally high level of stability with a recommended re-calibration period of 12 months, offering a low total cost of ownership.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous analysis of CH4, N2O and H2O\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional CO2 sensor\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow-ppb detection limits for CH4 and N2O Response time 60 seconds\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh dynamic range and stable operation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow sample volume (few ml)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in gas exchange system\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRecommended re-calibration interval of12 months\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser configurable monitoring tasks\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in display presents results both numerically and graphically\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas cell stabilized to 50 °C and 350 mbar to avoid drifts due to changes in environmental conditions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDrift-free operation due to direct absorption measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Performance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDetection Limit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 ppb for N2O, 10 ppb for CH4, 100 ppm for H2O, 0.2 ppm for CO2 (optional) \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResponse Time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fixed 60 seconds response time\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDynamic Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0-100 ppm for N2O \u0026amp; CH4, 0-60 000 ppm for H2O, 0-20 000 ppm for CO2 (optional)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRepeatability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 1% of measured value in operational conditions at the calibration concentration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3% at the calibration concentration. Limited by the calibration gas accuracy\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No drift due to ambient temperature or pressure variations within recommended working conditions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eSystem Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eForm Factor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19” 3U rack-mount \/ tabletop unit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48.4 × 13.9 × 44 cm (19.1 × 5.5 × 17.3 in)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ~13 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDisplay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in computer with 7” WSVGA screen\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInternal Gas Volume:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30 ml\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eData Storage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥ 1 year continuous monitoring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eOperating Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTemperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHumidity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 750–1050 mbar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDust\/water resistance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20 (IEC 529)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSample Gas Conditions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTemperature: 0°C to +49°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHumidity: Up to 99% RH (non-condensing, temperature dependent)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow Rate: ~0.6 L\/min\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParticle Size: \u0026lt; 1 µm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eElectrical \u0026amp; Interfaces\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInput Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 90–264 VAC, 47–63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Max. 75 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInterfaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ethernet, USB, optional Serial\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProtocols:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e MODBUS, AK protocol\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Current or voltage signal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eCompliance \u0026amp; Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLow Voltage Directive 2014\/35\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEMC Directive 2004\/108\/EC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS 2 Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAnimal husbandry\u003c\/li\u003e\n\u003cli\u003eEcology Research\u003c\/li\u003e\n\u003cli\u003eSoil Analysis\u003c\/li\u003e\n\u003cli\u003eGreenhouse gases research\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated publications:\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/PAS_GasAnalysisWithCantileverMicrophone_ApplSpectrosRew_2007.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eApplied Spectroscopy Reviews (2007): Photoacoustic Gas Analysis Using Interferometric Cantilever Microphone\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-luminous-fast-follows enable-updated-hr-color\" id=\"model-response-message-contentr_df371a64cab24bb6\" dir=\"ltr\"\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/TunableDiodeLaserPAS_AppliedPhysB_Koskinen_2007.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eV. Koskinen et al, “Cantilever enhanced photoacoustic detection of carbon dioxide using a tunable diode laser source”, Appl. Phys. B (2007)\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/FastSensorDifferentialPhotoacoustic_TeMe_2012_0173.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eSensitive and fast gas sensor for wide variety of applications based on novel differential infrared photoacoustic principle (2012) – Results from MINIGAS and GHG Flux -projects\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eIf you are interested in other gas types or multi-gas analyzers, please \u003cstrong\u003e\u003cem\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e \u003c\/em\u003e\u003c\/strong\u003eabout your application: \u003c\/p\u003e\n\u003cp\u003e• Formaldehyde\u003cbr\u003e• Greenhouse gases\u003cbr\u003e• HF, HCl, HCN, SO2, NO2, EtO\u003cbr\u003e• SF6, NOVEC\u003cbr\u003e• CF4, PFCs\u003cbr\u003e• Benzene\u003cbr\u003e• Many more!\u003c\/p\u003e","brand":"Gasera","offers":[{"title":"Default Title","offer_id":41461840183354,"sku":"GASERA ONE GHG","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/gaseraoneghg.png?v=1781826404","url":"https:\/\/www.msesupplies.com\/products\/gasera-one-greenhouse-gas-analyzer","provider":"MSE Supplies","version":"1.0","type":"link"}