{"product_id":"gasera-one-formaldehyde-gas-analyzer","title":"Gasera One Formaldehyde Gas Analyzer","description":"\u003ch2\u003eGasera One Formaldehyde Gas Analyzer\u003c\/h2\u003e\n\u003cp\u003eMSE Supplies is an authorized distributor of Gasera Products in the US. \u003cstrong\u003e\u003cem\u003ePlease\u003cspan\u003e fill out the application questionnaire and \u003c\/span\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e\u003cspan\u003e to discuss the application and configurations.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eIntroduction\u003c\/h3\u003e\n\u003cp style=\"text-align: left;\"\u003eFormaldehyde levels above 0.1 ppm can cause acute health problems, e.g. sore throat, skin irritation, nausea, scratchy eyes and cough. It is also classified as highly carcinogenic compound. Exposure to moderate amounts of formaldehyde has been linked to cancer, such as leukemia.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eGASERA ONE FORMALDEHYDE analyzer is based on combining ultra sensitive cantilever enhanced photoacoustic detection technology with Quantum Cascade Laser source operating at a Mid-IR fundamental spectral absorption line of formaldehyde. This combination provides enough sensitivity to reliably measure ambient background levels of formaldehyde. It also gives an exceptionally high level of stability with a re-calibration period ranging from several months up to several years, and thus it offers a low total cost of ownership.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelective monitoring of formaldehyde with below 1 ppb detection limit\u003c\/li\u003e\n\u003cli\u003eResponse time user configurable from 10 seconds to few minutes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWide dynamic range and stable operation\u003c\/li\u003e\n\u003cli\u003eNo consumables\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow sample volume (few ml)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in gas exchange system\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRecommended re-calibration interval of 12 months\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser configurable monitoring tasks\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in display presents results both numerically and graphically\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement pressure is actively controlled to be constant\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas cell is stabilized to 50°C temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Performance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDetection Limit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 1 ppb\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResponse Time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 seconds to several minutes (configurable)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDynamic Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026gt; 100,000× detection limit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRepeatability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 1% of measured value\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Better than ±5% at calibration concentration\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No drift due to ambient temperature or pressure variations within recommended working conditions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eSystem Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eForm Factor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19” 3U rack-mount \/ tabletop unit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48.4 × 13.9 × 44 cm (19.1 × 5.5 × 17.3 in)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ~13 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDisplay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in computer with 7” WSVGA screen\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInternal Gas Volume:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30 ml\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eData Storage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥ 1 year continuous monitoring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eOperating Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTemperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHumidity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 750–1050 mbar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDust\/water resistance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20 (IEC 529)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSample Gas Conditions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTemperature: 0°C to +49°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHumidity: Up to 99% RH (non-condensing, temperature dependent)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow Rate: ~0.6 L\/min\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParticle Size: \u0026lt; 1 µm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eElectrical \u0026amp; Interfaces\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInput Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 90–264 VAC, 47–63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Max. 75 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInterfaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ethernet, USB, optional Serial\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProtocols:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e MODBUS, AK protocol\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Current or voltage signal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eCompliance \u0026amp; Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLow Voltage Directive 2014\/35\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEMC Directive 2004\/108\/EC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS 2 Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eFence-line monitoring\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBiogas plants\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNew buildings\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWood products\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTraffic emissions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndoor air quality\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLaboratory Occupational safety\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated publications:\u003c\/h3\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-updated-hr-color\" id=\"model-response-message-contentr_2236d61e5ada7fdc\" dir=\"ltr\"\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/Hirchmann_Formaldehyde_2013.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eC. B. Hirchmann – Sub-ppb detection of formaldehyde with cantilever enhanced photoacoustic spectroscopy using quantum cascade laser source – Appl. Phys. B, (2013)\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-updated-hr-color\" id=\"model-response-message-contentr_b6dae140b3eeb6c5\" dir=\"ltr\"\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/PAS_GasAnalysisWithCantileverMicrophone_ApplSpectrosRew_2007.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eApplied Spectroscopy Reviews (2007): Photoacoustic Gas Analysis Using Interferometric Cantilever Microphone\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp\u003eIf you are interested in other gas types or multi-gas analyzers, please \u003cstrong\u003e\u003cem\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e \u003c\/em\u003e\u003c\/strong\u003eabout your application: \u003c\/p\u003e\n\u003cp\u003e• Formaldehyde\u003cbr\u003e• Greenhouse gases\u003cbr\u003e• HF, HCl, HCN, SO2, NO2, EtO\u003cbr\u003e• SF6, NOVEC\u003cbr\u003e• CF4, PFCs\u003cbr\u003e• Benzene\u003cbr\u003e• Many more!\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Gasera","offers":[{"title":"Default Title","offer_id":41461839757370,"sku":"GASERA1 FORMALDEHYDE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Gaseraoneformaldehyde.png?v=1781734922","url":"https:\/\/www.msesupplies.com\/products\/gasera-one-formaldehyde-gas-analyzer","provider":"MSE Supplies","version":"1.0","type":"link"}