{"product_id":"cleaver-scientific-denaturing-gradient-gel-electrophoresis-casting-package-and-accessories","title":"Cleaver Scientific Denaturing Gradient Gel Electrophoresis Casting Package and Accessories","description":"\u003ch2\u003eCleaver Scientific Denaturing Gradient Gel Electrophoresis Casting Package and Accessories\u003c\/h2\u003e\n\u003ch3\u003eDGGE Temperature Control Unit\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe redesigned VS20DGGETC temperature control unit combines buffer recirculation with a heat sensor and 1.4kW heating element to facilitate precise temperature control to within 0.02C, allowing the gel temperature to be set to the melting temperature (Tm) of the amplified DNA polymorphism or mutation of interest. Other benefits include; a conspicuous 4-digit 16mm LED panel to aid set-up, precise tuning to within 0.1C resolution, an operating set point, plus three adjustable pre-set temperature values, and stirred buffer circulation for temperature stability and uniformity.\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5677%;\"\u003e\u003cimg src=\"https:\/\/www.thistlescientific.co.uk\/wp-content\/uploads\/2024\/11\/DGGE-TC-1.WEB_-600x600.jpg\" alt=\"DGGE-TC-1.WEB.jpg\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0808%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement Control unit for CSL-DGGE\u003c\/li\u003e\n\u003cli\u003e4 digit LED display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDGGE System with Casting Package\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eDenaturing Gradient Gel Electrophoresis (DGGE) is an important technique used in the search for mutations and DNA polymorphisms critical in genetic disorders and cancers, and to understand genetic diversity among species. The new omniPAGE VS20WAVE-DGGE is a flexible system that can be fully customized to perform several different mutation detection techniques. The VS20WAVE-DGGE is a versatile single-unit solution for different single-base pair mutation detection methods. The newly designed VS20WAVE-DGGE is a complete system for DNA mutation analysis.\u003c\/p\u003e\n\u003cp\u003eUsing the innovative vertical screw-clamp technology of the new VS20-WAVE system, the VS20WAVE-DGGE is fully equipped with temperature control unit, stirrer, and gradient mixer and casting accessories to perform specific mutation analysis applications. A powerful microprocessor-controlled PID temperature control unit enables various mutation detection techniques to be undertaken between ambient temperature and 70C, while the simple fourscrew design of the WAVE insert accelerates set up of denaturing PAGE gels. Accordingly, the new VS20-DGGE can be used to screen single-base pair changes in the following applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeteroduplex analysis (HA)\u003c\/li\u003e\n\u003cli\u003eParallel Denaturing Gradient Gel Electrophoresis (DGGE)\u003c\/li\u003e\n\u003cli\u003eConstant Denaturing Gradient Gel Electrophoresis (CDGE)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe flexibility provided by the modular design of the VS20WAVE-DGGE and its wide range of accessories enables laboratories to switch quickly and easily between different mutation detection techniques, thereby maximizing throughput and screening efficiency. A maximum 96-sample throughput allows detection of as many mutations within a couple hours, alleviating many of the bottlenecks associated with screening for DNA mutations.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGM100 Gradient Mixer ensures efficient gradient formation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GM100 gradient mixer is supplied as standard to ensure efficient gradient formation by mixing and delivering high- and low-density denaturant solutions. A flat-base design and support handle allows the GM100 to be secured to a retort stand, enabling it to be easily mounted on a magnetic stirring plate (e.g. CSL-STIR), while the mixing chamber can accommodate a magnetic stirrer to form a linear gradient. The MU-D01 peristaltic pump is also recommended for delivery of linear and reproducible gradient gels.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInnovative casting and set-up mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VS20WAVE-DGGE utilizes novel vertical screw clamp technology to assemble two vertical gels. This reduces the number of screws required for set up making casting assembly faster, while a built-in inner buffer chamber within the PAGE insert allows set-up to be completed without the inclusion of heavy top tanks or buffer chambers. A dual purpose PAGE insert eliminates the need for plate transfer, and is used with a cam casting base to guarantee efficient leak free casting.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUtilizes the same combs and accessories as standard VS20 systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VS20WAVE-DGGE can use all of the combs, glass plates and accessories of existing VS20 units, providing full flexibility. Two 1mm 24-sample combs are supplied as standard while optional 48-sample combs allow screening to take place directly from 96-well thermal cycler blocks after PCR amplification.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5677%;\"\u003e\u003cimg alt=\"DGGE-1.WEB.jpg\" src=\"https:\/\/www.thistlescientific.co.uk\/wp-content\/uploads\/2024\/11\/DGGE-1.WEB_-600x600.jpg\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0808%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum 96-sample throughput compatible with microplates and thermal cycler blocks\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFour-screw vertical clamping technology accelerates set up\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge format 20x20cm glass plates for improved resolution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eincludes: VS20WAVE-DGGE, CSL-DSTIR, PP1, MU-S16, PowerPro 500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-controlled temperature control unit accurate to 0.02C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cbr\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable style=\"width: 539px; border-collapse: collapse;\" width=\"471\" cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes; height: 15.0pt;\"\u003e\n\u003ctd style=\"width: 219.141px; border: 1pt solid windowtext; padding: 0cm 5.4pt; height: 15pt;\" width=\"180\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eSKU\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 288.109px; border-top: 1pt solid windowtext; border-right: 1pt solid windowtext; border-bottom: 1pt solid windowtext; border-image: initial; border-left: none; padding: 0cm 5.4pt; height: 15pt;\" width=\"291\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eVS20WAVE-DGGEKIT$\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1; height: 15.0pt;\"\u003e\n\u003ctd style=\"width: 219.141px; border-right: 1pt solid windowtext; border-bottom: 1pt solid windowtext; border-left: 1pt solid windowtext; border-image: initial; border-top: none; padding: 0cm 5.4pt; height: 15pt;\" width=\"180\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eIncludes Power Supply\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 288.109px; border-top: none; border-left: none; border-bottom: 1pt solid windowtext; border-right: 1pt solid windowtext; padding: 0cm 5.4pt; height: 15pt;\" width=\"291\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; height: 15.0pt;\"\u003e\n\u003ctd style=\"width: 219.141px; border-right: 1pt solid windowtext; border-bottom: 1pt solid windowtext; border-left: 1pt solid windowtext; border-image: initial; border-top: none; padding: 0cm 5.4pt; height: 15pt;\" width=\"180\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eTechnique\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 288.109px; border-top: none; border-left: none; border-bottom: 1pt solid windowtext; border-right: 1pt solid windowtext; padding: 0cm 5.4pt; height: 15pt;\" width=\"291\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eDenaturing Gradient Gel Electrophoresis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3; height: 30.0pt;\"\u003e\n\u003ctd style=\"width: 219.141px; border-right: 1pt solid windowtext; border-bottom: 1pt solid windowtext; border-left: 1pt solid windowtext; border-image: initial; border-top: none; padding: 0cm 5.4pt; height: 30pt;\" width=\"180\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003ePackage Includes\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 288.109px; border-top: none; border-left: none; border-bottom: 1pt solid windowtext; border-right: 1pt solid windowtext; padding: 0cm 5.4pt; height: 30pt;\" width=\"291\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eVS20WAVE-DGGE$, CSL-DSTIR$, MU-S16, POWERPRO500, PP1$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4; mso-yfti-lastrow: yes; height: 15.0pt;\"\u003e\n\u003ctd style=\"width: 219.141px; border-right: 1pt solid windowtext; border-bottom: 1pt solid windowtext; border-left: 1pt solid windowtext; border-image: initial; border-top: none; padding: 0cm 5.4pt; height: 15pt;\" width=\"180\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003eInput Voltage\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 288.109px; border-top: none; border-left: none; border-bottom: 1pt solid windowtext; border-right: 1pt solid windowtext; padding: 0cm 5.4pt; height: 15pt;\" width=\"291\"\u003e\n\u003cp style=\"margin-bottom: 0cm; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Calibri',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e115\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDGGE System Outer Tank, No Temperature Control Unit\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 202.531px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 202.531px;\"\u003e\n\u003ctd style=\"width: 33.5677%; height: 202.531px;\"\u003e\u003cimg src=\"https:\/\/www.thistlescientific.co.uk\/wp-content\/uploads\/2024\/11\/DGGE-TANK-Image-380x380.jpg\" alt=\"DGGE System Outer Tank, No Temperature Control Unit\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0808%; height: 202.531px;\"\u003e\n\u003cp\u003eReplacement tank for the Denaturing Gradient Gel Electrophoresis (DGGE) System. Tank only, Temperature Control Unit is not included.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDGGE System lid\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 202.531px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 202.531px;\"\u003e\n\u003ctd style=\"width: 33.5677%; height: 202.531px;\"\u003e\u003cimg src=\"https:\/\/www.thistlescientific.co.uk\/wp-content\/uploads\/2024\/11\/DGGE-LID-380x380.jpg\" alt=\"DGGE System lid\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0808%; height: 202.531px;\"\u003e\n\u003cp\u003eReplacement lid for the Denaturing Gradient Gel Electrophoresis System. No cables are Included.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003ciframe width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/mN3W3Vgm9H8\" title=\"Cleaver Scientific DGGE Training Video Practical\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eInstructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DGGE_MANUAL.pdf?v=1774519870\"\u003eDGGE MANUAL(PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Flyers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Cleaver_Scientific_catalogue_page_58.pdf?v=1774519869\"\u003eCleaver Scientific catalogue page 58(PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Cleaver_Scientific_catalogue_page_59.pdf?v=1774521446\"\u003eCleaver Scientific catalogue page 59(PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DGGE.WEB.pdf?v=1774519870\"\u003eDGGE.WEB(PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eMSE Supplies is an authorized supplier of Cleaver Scientific (Thistle Scientific) products. Please contact us if you need more information regarding Cleaver Scientific products and equipment.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Cleaver Scientific","offers":[{"title":"DGGE Temperature Control Unit - 115V","offer_id":41281557659706,"sku":"VS20WAVE-DGGETC$","price":2721.95,"currency_code":"USD","in_stock":true},{"title":"DGGE System with Casting Package - 115V","offer_id":41281557692474,"sku":"VS20WAVE-DGGEKIT$","price":11979.95,"currency_code":"USD","in_stock":true},{"title":"DGGE System Outer Tank, No Temperature Control Unit","offer_id":41281557725242,"sku":"VS20WAVE-DGGETANK","price":2657.95,"currency_code":"USD","in_stock":true},{"title":"DGGE System lid","offer_id":41281557758010,"sku":"VS20DGGE-LID","price":498.95,"currency_code":"USD","in_stock":true},{"title":"VS20wave Page insert for DGGE UNIT","offer_id":41281557790778,"sku":"VS20WAVEDIRM-DGGE","price":799.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/VS20WAVE-DGGETC.jpg?v=1774520667","url":"https:\/\/www.msesupplies.com\/products\/cleaver-scientific-denaturing-gradient-gel-electrophoresis-casting-package-and-accessories","provider":"MSE Supplies","version":"1.0","type":"link"}