{"product_id":"buck-scientific-pfp-7c-clinical-flame-photometer","title":"Buck Scientific PFP-7C Clinical Flame Photometer","description":"\u003ch2 data-section-id=\"1armlji\" data-start=\"0\" data-end=\"50\" class=\"PDq2pG_selectionAnchorContainer\"\u003eBuck Scientific PFP-7C Clinical Flame Photometer\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3 data-section-id=\"13ax1s5\" data-start=\"52\" data-end=\"67\"\u003eIntroduction\u003c\/h3\u003e\n\u003cp data-start=\"69\" data-end=\"634\"\u003eThe \u003cstrong data-start=\"73\" data-end=\"125\"\u003eBuck Scientific PFP-7C Clinical Flame Photometer\u003c\/strong\u003e is designed specifically for clinical laboratory applications. Based on the \u003ca href=\"https:\/\/www.msesupplies.com\/products\/buck-scientific-pfp-7-flame-photometer-110v?variant=41402669334586\"\u003ePFP-7 flame photometer platform\u003c\/a\u003e, the PFP-7C includes built-in lineariser circuitry that allows sodium and potassium readings at normal clinical serum concentrations to be displayed directly in \u003cstrong data-start=\"395\" data-end=\"403\"\u003emmol\u003c\/strong\u003e. It is suitable for routine clinical determination of sodium and potassium, while also supporting additional element measurements such as lithium, calcium, and barium with appropriate filters.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ma7m6t\" data-start=\"636\" data-end=\"651\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"653\" data-end=\"1056\"\u003e\n\u003cli data-section-id=\"o8vscc\" data-start=\"653\" data-end=\"721\"\u003eDesigned specifically for clinical sodium and potassium analysis\u003c\/li\u003e\n\u003cli data-section-id=\"g2z3ug\" data-start=\"722\" data-end=\"780\"\u003eBuilt-in lineariser circuitry for direct mmol readings\u003c\/li\u003e\n\u003cli data-section-id=\"5brpqn\" data-start=\"781\" data-end=\"855\"\u003eAnalytical ranges for Na and K at normal clinical serum concentrations\u003c\/li\u003e\n\u003cli data-section-id=\"92ypp9\" data-start=\"856\" data-end=\"919\"\u003ePush-button ignition and electronic flame failure detection\u003c\/li\u003e\n\u003cli data-section-id=\"1ol37my\" data-start=\"920\" data-end=\"985\"\u003eFilter wheel for fast switching between analytical parameters\u003c\/li\u003e\n\u003cli data-section-id=\"1depn83\" data-start=\"986\" data-end=\"1056\"\u003eCompatible with propane, butane, natural gas, or LPG fuel supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1a3ueyz\" data-start=\"1058\" data-end=\"1075\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1077\" data-end=\"2260\" data-is-last-node=\"\" data-is-only-node=\"\" class=\"w-fit min-w-(--thread-content-width)\" height=\"667\" style=\"width: 86.4836%;\"\u003e\n\u003ctbody data-start=\"1117\" data-end=\"2260\" data-is-last-node=\"\"\u003e\n\u003ctr data-start=\"1117\" data-end=\"1143\"\u003e\n\u003ctd data-start=\"1117\" data-end=\"1133\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eProduct Model\u003c\/td\u003e\n\u003ctd data-start=\"1133\" data-end=\"1143\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003ePFP-7C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1144\" data-end=\"1187\"\u003e\n\u003ctd data-start=\"1144\" data-end=\"1158\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"1158\" data-end=\"1187\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eClinical flame photometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1188\" data-end=\"1246\"\u003e\n\u003ctd data-start=\"1188\" data-end=\"1216\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003ePrimary Clinical Elements\u003c\/td\u003e\n\u003ctd data-start=\"1216\" data-end=\"1246\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eSodium (Na), Potassium (K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1247\" data-end=\"1290\"\u003e\n\u003ctd data-start=\"1247\" data-end=\"1273\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eSodium Analytical Range\u003c\/td\u003e\n\u003ctd data-start=\"1273\" data-end=\"1290\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e0.04 – 1.1 mM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1291\" data-end=\"1337\"\u003e\n\u003ctd data-start=\"1291\" data-end=\"1320\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003ePotassium Analytical Range\u003c\/td\u003e\n\u003ctd data-start=\"1320\" data-end=\"1337\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e0.02 – 1.4 mM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1338\" data-end=\"1403\"\u003e\n\u003ctd data-start=\"1338\" data-end=\"1360\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eAdditional Elements\u003c\/td\u003e\n\u003ctd data-start=\"1360\" data-end=\"1403\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eLithium (Li), Calcium (Ca), Barium (Ba)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1404\" data-end=\"1437\"\u003e\n\u003ctd data-start=\"1404\" data-end=\"1425\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eLi Detection Limit\u003c\/td\u003e\n\u003ctd data-start=\"1425\" data-end=\"1437\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e0.25 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1438\" data-end=\"1474\"\u003e\n\u003ctd data-start=\"1438\" data-end=\"1457\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eLi Working Range\u003c\/td\u003e\n\u003ctd data-start=\"1457\" data-end=\"1474\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e0.75 – 20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1475\" data-end=\"1508\"\u003e\n\u003ctd data-start=\"1475\" data-end=\"1496\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eCa Detection Limit\u003c\/td\u003e\n\u003ctd data-start=\"1496\" data-end=\"1508\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e1.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1509\" data-end=\"1545\"\u003e\n\u003ctd data-start=\"1509\" data-end=\"1528\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eCa Working Range\u003c\/td\u003e\n\u003ctd data-start=\"1528\" data-end=\"1545\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e3.00 – 40 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1546\" data-end=\"1579\"\u003e\n\u003ctd data-start=\"1546\" data-end=\"1567\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eBa Detection Limit\u003c\/td\u003e\n\u003ctd data-start=\"1567\" data-end=\"1579\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e2.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1580\" data-end=\"1617\"\u003e\n\u003ctd data-start=\"1580\" data-end=\"1599\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eBa Working Range\u003c\/td\u003e\n\u003ctd data-start=\"1599\" data-end=\"1617\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e5.00 – 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1618\" data-end=\"1728\"\u003e\n\u003ctd data-start=\"1618\" data-end=\"1636\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eReproducibility\u003c\/td\u003e\n\u003ctd data-start=\"1636\" data-end=\"1728\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e\u0026lt;1% coefficient of variation for 20 consecutive samples using 10 ppm Na set to read 50.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1729\" data-end=\"1812\"\u003e\n\u003ctd data-start=\"1729\" data-end=\"1741\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eLinearity\u003c\/td\u003e\n\u003ctd data-start=\"1741\" data-end=\"1812\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eBetter than 2% when 3 ppm Na and K and 5 ppm Li are set to read 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1813\" data-end=\"1923\"\u003e\n\u003ctd data-start=\"1813\" data-end=\"1827\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eSpecificity\u003c\/td\u003e\n\u003ctd data-start=\"1827\" data-end=\"1923\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eInterference from Na, K, and Li equal in concentration to the test element is less than 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1924\" data-end=\"1983\"\u003e\n\u003ctd data-start=\"1924\" data-end=\"1942\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eRecorder Output\u003c\/td\u003e\n\u003ctd data-start=\"1942\" data-end=\"1983\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eNominal 1.00 V for a reading of 100.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1984\" data-end=\"2039\"\u003e\n\u003ctd data-start=\"1984\" data-end=\"2004\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eElectrical Supply\u003c\/td\u003e\n\u003ctd data-start=\"2004\" data-end=\"2039\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e90–125 V \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2040\" data-end=\"2118\"\u003e\n\u003ctd data-start=\"2040\" data-end=\"2058\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eAir Requirement\u003c\/td\u003e\n\u003ctd data-start=\"2058\" data-end=\"2118\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003eMoisture- and oil-free air, 6 L\/min at 1 kg\/cm² \/ 14 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2119\" data-end=\"2166\"\u003e\n\u003ctd data-start=\"2119\" data-end=\"2126\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eFuel\u003c\/td\u003e\n\u003ctd data-start=\"2126\" data-end=\"2166\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003ePropane, butane, natural gas, or LPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2167\" data-end=\"2196\"\u003e\n\u003ctd data-start=\"2167\" data-end=\"2183\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eDisplay Range\u003c\/td\u003e\n\u003ctd data-start=\"2183\" data-end=\"2196\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e0 – 199.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2197\" data-end=\"2232\"\u003e\n\u003ctd data-start=\"2197\" data-end=\"2210\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2210\" data-end=\"2232\" style=\"width: 62.2593%;\"\u003e420 × 360 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2233\" data-end=\"2260\" data-is-last-node=\"\"\u003e\n\u003ctd data-start=\"2233\" data-end=\"2242\" data-col-size=\"sm\" style=\"width: 37.2694%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2242\" data-end=\"2260\" data-is-last-node=\"\" data-col-size=\"md\" style=\"width: 62.2593%;\"\u003e8 kg \/ 17.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Buck Scientific","offers":[{"title":"Default Title","offer_id":41402669531194,"sku":"PFP-7C","price":8977.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/PFP-7_0abe69ea-990c-42af-a41c-fc85ab58b159.png?v=1782947920","url":"https:\/\/www.msesupplies.com\/products\/buck-scientific-pfp-7c-clinical-flame-photometer","provider":"MSE Supplies","version":"1.0","type":"link"}