{"product_id":"buck-scientific-alchemist-1600-microwave-digestion-system","title":"Buck Scientific Alchemist 1600 Microwave Digestion System","description":"\u003ch2 data-section-id=\"1k5isck\" data-start=\"0\" data-end=\"60\"\u003eBuck Scientific Alchemist 1600 Microwave Digestion System\u003c\/h2\u003e\n\u003cp data-start=\"62\" data-end=\"139\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong data-start=\"62\" data-end=\"139\"\u003eMSE Supplies is an authorized distributor of Buck Scientific instruments.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"141\" data-end=\"210\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong data-start=\"141\" data-end=\"210\"\u003eBuy Buck Scientific products from MSE Supplies at the best value.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"212\" data-end=\"617\"\u003eThe \u003cstrong data-start=\"216\" data-end=\"277\"\u003eBuck Scientific Alchemist 1600 Microwave Digestion System\u003c\/strong\u003e is designed for simple, efficient, and reliable microwave sample digestion. Built on over 20 years of refinement, the system features a 7-inch color touchscreen, variable 0–1000 W microwave power, tool-less finger-tight vessels, and advanced safety controls for routine laboratory digestion workflows.\u003c\/p\u003e\n\u003cp data-start=\"619\" data-end=\"949\"\u003eThe Alchemist 1600 can operate with \u003cstrong data-start=\"655\" data-end=\"671\"\u003e1–16 vessels\u003c\/strong\u003e and automatically counts the vessels at the beginning of each run to adjust power accordingly. Its onboard computer can store and edit up to \u003cstrong data-start=\"813\" data-end=\"840\"\u003e255 user preset methods\u003c\/strong\u003e, with parameters for time, temperature, pressure, and microwave power.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"951\" data-end=\"963\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"965\" data-end=\"1682\"\u003e\n\u003cli data-section-id=\"166ri1b\" data-start=\"965\" data-end=\"1001\"\u003e7-inch color touchscreen interface\u003c\/li\u003e\n\u003cli data-section-id=\"1zcfko\" data-start=\"1002\" data-end=\"1043\"\u003eStores up to 255 user-installed methods\u003c\/li\u003e\n\u003cli data-section-id=\"5565d6\" data-start=\"1044\" data-end=\"1081\"\u003e0–1000 W adjustable microwave power\u003c\/li\u003e\n\u003cli data-section-id=\"1r9o7tf\" data-start=\"1082\" data-end=\"1146\"\u003eUser-set parameters for time, temperature, pressure, and power\u003c\/li\u003e\n\u003cli data-section-id=\"qa57os\" data-start=\"1147\" data-end=\"1196\"\u003eTool-less finger-tight vessels for faster setup\u003c\/li\u003e\n\u003cli data-section-id=\"3dg7sz\" data-start=\"1197\" data-end=\"1219\"\u003e1–16 vessel capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1q6lgq7\" data-start=\"1220\" data-end=\"1269\"\u003eContactless temperature and pressure monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1j0i1ng\" data-start=\"1270\" data-end=\"1330\"\u003eReal-time temperature and pressure display for each vessel\u003c\/li\u003e\n\u003cli data-section-id=\"42xos7\" data-start=\"1331\" data-end=\"1379\"\u003eAutomatic vessel counting and power adjustment\u003c\/li\u003e\n\u003cli data-section-id=\"9t68az\" data-start=\"1380\" data-end=\"1435\"\u003eContinuous 360° rotating carousel for uniform heating\u003c\/li\u003e\n\u003cli data-section-id=\"jddtzl\" data-start=\"1436\" data-end=\"1484\"\u003eHigh-tensile steel door with double interlocks\u003c\/li\u003e\n\u003cli data-section-id=\"15pz7x0\" data-start=\"1485\" data-end=\"1545\"\u003eAudible anomaly detection system for vessel rupture alerts\u003c\/li\u003e\n\u003cli data-section-id=\"mfqyqm\" data-start=\"1546\" data-end=\"1623\"\u003eTriple TFM-coated 316 stainless steel construction for corrosion resistance\u003c\/li\u003e\n\u003cli data-section-id=\"1izqxif\" data-start=\"1624\" data-end=\"1682\"\u003eNo rupture discs or costly temperature probes to replace\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1684\" data-end=\"1712\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1714\" data-end=\"2700\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1714\" data-end=\"1741\"\u003e\n\u003ctr data-start=\"1714\" data-end=\"1741\"\u003e\n\u003cth data-start=\"1714\" data-end=\"1730\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1730\" data-end=\"1741\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1752\" data-end=\"2700\"\u003e\n\u003ctr data-start=\"1752\" data-end=\"1778\"\u003e\n\u003ctd data-start=\"1752\" data-end=\"1760\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1760\" data-end=\"1778\" data-col-size=\"md\"\u003eAlchemist 1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1779\" data-end=\"1803\"\u003e\n\u003ctd data-start=\"1779\" data-end=\"1797\" data-col-size=\"sm\"\u003eVessel Quantity\u003c\/td\u003e\n\u003ctd data-start=\"1797\" data-end=\"1803\" data-col-size=\"md\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1804\" data-end=\"1877\"\u003e\n\u003ctd data-start=\"1804\" data-end=\"1829\" data-col-size=\"sm\"\u003eTemperature Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"1829\" data-end=\"1877\" data-col-size=\"md\"\u003eContactless IR sensor temperature monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1878\" data-end=\"1938\"\u003e\n\u003ctd data-start=\"1878\" data-end=\"1900\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"1900\" data-end=\"1938\" data-col-size=\"md\"\u003eEach vessel temperature controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1939\" data-end=\"1970\"\u003e\n\u003ctd data-start=\"1939\" data-end=\"1959\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"1959\" data-end=\"1970\" data-col-size=\"md\"\u003e0–400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1971\" data-end=\"2004\"\u003e\n\u003ctd data-start=\"1971\" data-end=\"1994\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1994\" data-end=\"2004\" data-col-size=\"md\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2005\" data-end=\"2034\"\u003e\n\u003ctd data-start=\"2005\" data-end=\"2024\" data-col-size=\"sm\"\u003eDisplay Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2024\" data-end=\"2034\" data-col-size=\"md\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2035\" data-end=\"2099\"\u003e\n\u003ctd data-start=\"2035\" data-end=\"2057\" data-col-size=\"sm\"\u003ePressure Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"2057\" data-end=\"2099\" data-col-size=\"md\"\u003eContactless sensor pressure monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2100\" data-end=\"2154\"\u003e\n\u003ctd data-start=\"2100\" data-end=\"2119\" data-col-size=\"sm\"\u003ePressure Control\u003c\/td\u003e\n\u003ctd data-start=\"2119\" data-end=\"2154\" data-col-size=\"md\"\u003eEach vessel pressure controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2155\" data-end=\"2184\"\u003e\n\u003ctd data-start=\"2155\" data-end=\"2172\" data-col-size=\"sm\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd data-start=\"2172\" data-end=\"2184\" data-col-size=\"md\"\u003e0–15 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2185\" data-end=\"2217\"\u003e\n\u003ctd data-start=\"2185\" data-end=\"2205\" data-col-size=\"sm\"\u003ePressure Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2205\" data-end=\"2217\" data-col-size=\"md\"\u003e±0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2218\" data-end=\"2249\"\u003e\n\u003ctd data-start=\"2218\" data-end=\"2237\" data-col-size=\"sm\"\u003eDisplay Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2237\" data-end=\"2249\" data-col-size=\"md\"\u003e±0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2250\" data-end=\"2275\"\u003e\n\u003ctd data-start=\"2250\" data-end=\"2266\" data-col-size=\"sm\"\u003eVessel Volume\u003c\/td\u003e\n\u003ctd data-start=\"2266\" data-end=\"2275\" data-col-size=\"md\"\u003e50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2276\" data-end=\"2327\"\u003e\n\u003ctd data-start=\"2276\" data-end=\"2305\" data-col-size=\"sm\"\u003eProtective Vessel Material\u003c\/td\u003e\n\u003ctd data-start=\"2305\" data-end=\"2327\" data-col-size=\"md\"\u003ePEEK + Glass Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2328\" data-end=\"2360\"\u003e\n\u003ctd data-start=\"2328\" data-end=\"2338\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2338\" data-end=\"2360\" data-col-size=\"md\"\u003e7-inch touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2361\" data-end=\"2414\"\u003e\n\u003ctd data-start=\"2361\" data-end=\"2372\" data-col-size=\"sm\"\u003eRotation\u003c\/td\u003e\n\u003ctd data-start=\"2372\" data-end=\"2414\" data-col-size=\"md\"\u003eOne-direction 360° continuous rotating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2415\" data-end=\"2490\"\u003e\n\u003ctd data-start=\"2415\" data-end=\"2432\" data-col-size=\"sm\"\u003eMicrowave Tank\u003c\/td\u003e\n\u003ctd data-start=\"2432\" data-end=\"2490\" data-col-size=\"md\"\u003e316L stainless steel tank with corrosion-proof coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2491\" data-end=\"2532\"\u003e\n\u003ctd data-start=\"2491\" data-end=\"2509\" data-col-size=\"sm\"\u003eMicrowave Power\u003c\/td\u003e\n\u003ctd data-start=\"2509\" data-end=\"2532\" data-col-size=\"md\"\u003e0–1000 W adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2533\" data-end=\"2566\"\u003e\n\u003ctd data-start=\"2533\" data-end=\"2553\" data-col-size=\"sm\"\u003eMicrowave Leakage\u003c\/td\u003e\n\u003ctd data-start=\"2553\" data-end=\"2566\" data-col-size=\"md\"\u003e\u0026lt;5 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2567\" data-end=\"2622\"\u003e\n\u003ctd data-start=\"2567\" data-end=\"2581\" data-col-size=\"sm\"\u003eAir Exhaust\u003c\/td\u003e\n\u003ctd data-start=\"2581\" data-end=\"2622\" data-col-size=\"md\"\u003eHigh-power corrosion-proof air blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2623\" data-end=\"2639\"\u003e\n\u003ctd data-start=\"2623\" data-end=\"2631\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"2631\" data-end=\"2639\" data-col-size=\"md\"\u003e220V, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2640\" data-end=\"2677\"\u003e\n\u003ctd data-start=\"2640\" data-end=\"2653\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2653\" data-end=\"2677\" data-col-size=\"md\"\u003e19.2 × 22 × 24.8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2678\" data-end=\"2700\"\u003e\n\u003ctd data-start=\"2678\" data-end=\"2687\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2687\" data-end=\"2700\" data-col-size=\"md\"\u003e103.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2702\" data-end=\"2718\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2720\" data-end=\"3011\"\u003e\n\u003cli data-section-id=\"13dzb1k\" data-start=\"2720\" data-end=\"2760\"\u003eMicrowave digestion sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"1vm2pee\" data-start=\"2761\" data-end=\"2800\"\u003eElemental analysis sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"14bwpzb\" data-start=\"2801\" data-end=\"2827\"\u003eAcid digestion workflows\u003c\/li\u003e\n\u003cli data-section-id=\"1g84s33\" data-start=\"2828\" data-end=\"2862\"\u003eEnvironmental sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"sofjni\" data-start=\"2863\" data-end=\"2903\"\u003eFood and agricultural sample digestion\u003c\/li\u003e\n\u003cli data-section-id=\"8k4tv4\" data-start=\"2904\" data-end=\"2939\"\u003ePharmaceutical sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"tp6kgx\" data-start=\"2940\" data-end=\"2980\"\u003eGeological and mining sample digestion\u003c\/li\u003e\n\u003cli data-section-id=\"1gl7lna\" data-start=\"2981\" data-end=\"3011\"\u003eIndustrial material analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"604\" style=\"border-collapse: collapse; width: 537px;\" height=\"88\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"137\" style=\"width: 104.5px;\"\u003e \u003ccol width=\"467\" style=\"width: 431.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"17\" style=\"height: 12.5pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl65\" width=\"137\" style=\"height: 12.5pt; width: 103pt;\"\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/products\/buck-scientific-56-position-hot-plate-for-sample-pre-treatment-and-evaporation?variant=41402668810298\"\u003eAlchemist 56\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd width=\"467\" style=\"width: 350pt;\"\u003e56 Position Hot Plate for sample pre-treatment and evaporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.5pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl65\" style=\"height: 12.5pt;\"\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/products\/buck-scientific-42-position-hot-plate-for-sample-pre-treatment-and-evaporation?variant=41402668875834\"\u003eAlchemist 42\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e42 Position Hot Plate for sample pre-treatment and evaporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.5pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl65\" style=\"height: 12.5pt;\"\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/products\/buck-scientific-complete-microwave-digestion-vessel-50ml?variant=41402668941370\"\u003eBMV-50\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete Microwave Digestion Vessel (50ml)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.5pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl65\" style=\"height: 12.5pt;\"\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/products\/buck-scientific-inner-sample-digestion-vessel-for-use-with-the-alchemist-42-56?variant=41402669006906\"\u003eBMV-50-IN\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eInner Sample Digestion Vessel (for use with the Alchemist 42 and Alchemist 56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Buck Scientific","offers":[{"title":"Default Title","offer_id":41402668744762,"sku":"Alchemist 1600","price":18714.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Alchemist1600.jpg?v=1780347180","url":"https:\/\/www.msesupplies.com\/products\/buck-scientific-alchemist-1600-microwave-digestion-system","provider":"MSE Supplies","version":"1.0","type":"link"}