{"product_id":"aqueous-compatible-screw-mount-raman-electrochemical-flow-h-cell-for-sample-size-23-mm-x-23-mm","title":"Aqueous Compatible Screw Mount Raman Electrochemical Flow H-Cell for sample size \u003c 23 mm x 23 mm","description":"\u003ch2\u003eAqueous Compatible Screw Mount Raman Electrochemical Flow H-Cell for sample size \u0026lt;  23 mm x 23mm\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eBuy Redox.me products from MSE Supplies at the best value.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIntroduction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis cell combines two classical analytical techniques such as electrochemistry and Raman spectroscopy, to obtain \u003c\/span\u003e\u003cem\u003ein-situ\u003c\/em\u003e\u003cspan\u003e chemical information about the reactions taking place during an electrochemical experiment. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1836nc4\" data-start=\"70\" data-end=\"131\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"74\" data-end=\"131\"\u003eKey Features \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"133\" data-end=\"190\"\u003e\u003cstrong data-start=\"133\" data-end=\"190\"\u003e1. Dual-Compartment Design with Ion-Exchange Membrane\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"191\" data-end=\"401\"\u003e\n\u003cli data-section-id=\"dzlcqb\" data-start=\"191\" data-end=\"246\"\u003ePhysically separates anode and cathode compartments\u003c\/li\u003e\n\u003cli data-section-id=\"s8472y\" data-start=\"247\" data-end=\"292\"\u003ePrevents mixing of reactants and products\u003c\/li\u003e\n\u003cli data-section-id=\"urs19x\" data-start=\"293\" data-end=\"345\"\u003eMinimizes cross-talk between electrode reactions\u003c\/li\u003e\n\u003cli data-section-id=\"1vidafu\" data-start=\"346\" data-end=\"401\"\u003eEnables more accurate electrocatalytic measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"403\" data-end=\"454\"\u003e\u003cstrong data-start=\"403\" data-end=\"454\"\u003e2. Independent Control of Reaction Environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"455\" data-end=\"669\"\u003e\n\u003cli data-section-id=\"1pn5kp\" data-start=\"455\" data-end=\"530\"\u003eDifferent electrolytes or pH conditions can be used in each compartment\u003c\/li\u003e\n\u003cli data-section-id=\"1brccb1\" data-start=\"531\" data-end=\"619\"\u003eAllows precise tuning of:\n\u003cul data-start=\"561\" data-end=\"619\"\u003e\n\u003cli data-section-id=\"1j3lrps\" data-start=\"561\" data-end=\"567\"\u003epH\u003c\/li\u003e\n\u003cli data-section-id=\"15kdsa7\" data-start=\"570\" data-end=\"588\"\u003eIonic strength\u003c\/li\u003e\n\u003cli data-section-id=\"1gju9aw\" data-start=\"591\" data-end=\"619\"\u003eSpecific ion composition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gf9q88\" data-start=\"620\" data-end=\"669\"\u003eIdeal for systematic electrocatalysis studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"671\" data-end=\"717\"\u003e\u003cstrong data-start=\"671\" data-end=\"717\"\u003e3. Reduced Side Reactions and Interference\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"718\" data-end=\"902\"\u003e\n\u003cli data-section-id=\"12a8gxa\" data-start=\"718\" data-end=\"782\"\u003eLimits unwanted reactions common in single-compartment cells\u003c\/li\u003e\n\u003cli data-section-id=\"15h3sd3\" data-start=\"783\" data-end=\"850\"\u003eMembrane blocks interfering species from reaching the electrode\u003c\/li\u003e\n\u003cli data-section-id=\"j9krtm\" data-start=\"851\" data-end=\"902\"\u003eImproves reliability and selectivity of results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"904\" data-end=\"944\"\u003e\u003cstrong data-start=\"904\" data-end=\"944\"\u003e4. Enhanced Stability and Durability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"945\" data-end=\"1061\"\u003e\n\u003cli data-section-id=\"1fui023\" data-start=\"945\" data-end=\"976\"\u003ePrevents electrolyte mixing\u003c\/li\u003e\n\u003cli data-section-id=\"1qcp9vv\" data-start=\"977\" data-end=\"1022\"\u003eReduces electrode fouling and degradation\u003c\/li\u003e\n\u003cli data-section-id=\"1fq2ngw\" data-start=\"1023\" data-end=\"1061\"\u003eEnsures stable long-term operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1063\" data-end=\"1102\"\u003e\u003cstrong data-start=\"1063\" data-end=\"1102\"\u003e5. Raman Spectroscopy Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1103\" data-end=\"1296\"\u003e\n\u003cli data-section-id=\"erea5d\" data-start=\"1103\" data-end=\"1161\"\u003eSapphire optical window enables in situ Raman analysis\u003c\/li\u003e\n\u003cli data-section-id=\"h3s2ap\" data-start=\"1162\" data-end=\"1235\"\u003eLaser focuses through a thin electrolyte layer (3.25 mm optical path)\u003c\/li\u003e\n\u003cli data-section-id=\"ienuqn\" data-start=\"1236\" data-end=\"1296\"\u003eSuitable for real-time monitoring of electrode processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1298\" data-end=\"1333\"\u003e\u003cstrong data-start=\"1298\" data-end=\"1333\"\u003e6. Modular and Versatile Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1334\" data-end=\"1511\"\u003e\n\u003cli data-section-id=\"19u339o\" data-start=\"1334\" data-end=\"1394\"\u003eSupports both 2-electrode and 3-electrode configurations\u003c\/li\u003e\n\u003cli data-section-id=\"1x9vqvi\" data-start=\"1395\" data-end=\"1456\"\u003eBottom-loading sample holder with magnetic or screw mount\u003c\/li\u003e\n\u003cli data-section-id=\"1dpxg6g\" data-start=\"1457\" data-end=\"1511\"\u003eTantalum foil provides reliable electrical contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1513\" data-end=\"1550\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1550\"\u003e7. Flexible Electrode Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1551\" data-end=\"1847\"\u003e\n\u003cli data-section-id=\"1rh613f\" data-start=\"1551\" data-end=\"1631\"\u003eCompatible with thin-film working electrodes on rigid or flexible substrates\u003c\/li\u003e\n\u003cli data-section-id=\"1npfht4\" data-start=\"1632\" data-end=\"1686\"\u003eOptional adapter supports 6 mm diameter electrodes\n\u003cp\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/products\/electrode-adapter-for-raman-ecfc?_pos=1\u0026amp;_psq=E-A-DISK_EA_RAM_ECFC\u0026amp;_ss=e\u0026amp;_v=1.0\u0026amp;variant=39338806149178\"\u003eElectrode Adapter For Raman ECFC\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mn0k35\" data-start=\"1687\" data-end=\"1847\"\u003eEnables use of various electrode types, including:\n\u003cul data-start=\"1742\" data-end=\"1847\"\u003e\n\u003cli data-section-id=\"c8yell\" data-start=\"1742\" data-end=\"1761\"\u003eDisk electrodes\u003c\/li\u003e\n\u003cli data-section-id=\"1mepo1l\" data-start=\"1764\" data-end=\"1789\"\u003eRods (e.g., graphite)\u003c\/li\u003e\n\u003cli data-section-id=\"1wnv2so\" data-start=\"1792\" data-end=\"1818\"\u003eMetal foils and meshes\u003c\/li\u003e\n\u003cli data-section-id=\"x57c67\" data-start=\"1821\" data-end=\"1847\"\u003eCarbon-based materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1849\" data-end=\"1906\"\u003e\u003cstrong data-start=\"1849\" data-end=\"1906\"\u003e8. Expandable to Gas Diffusion Electrode (GDE) System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1907\" data-end=\"2042\"\u003e\n\u003cli data-section-id=\"kur6x9\" data-start=\"1907\" data-end=\"1973\"\u003eConvertible to GDE configuration with optional gas compartment\u003c\/li\u003e\n\u003cli data-section-id=\"n8rd6u\" data-start=\"1974\" data-end=\"2042\"\u003eAllows use of gas diffusion electrodes for advanced applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2044\" data-end=\"2084\"\u003e\u003cstrong data-start=\"2044\" data-end=\"2084\"\u003e9. Chemically Resistant Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2085\" data-end=\"2235\"\u003e\n\u003cli data-section-id=\"1q8azvj\" data-start=\"2085\" data-end=\"2137\"\u003eBuilt from inert materials (PEEK, fluorocarbons)\u003c\/li\u003e\n\u003cli data-section-id=\"qfxat9\" data-start=\"2138\" data-end=\"2235\"\u003eCompatible with:\n\u003cul data-start=\"2159\" data-end=\"2235\"\u003e\n\u003cli data-section-id=\"3f1wlu\" data-start=\"2159\" data-end=\"2197\"\u003eAqueous electrolytes (FKM O-rings)\u003c\/li\u003e\n\u003cli data-section-id=\"re4su1\" data-start=\"2200\" data-end=\"2235\"\u003eOrganic solvents (FFKM O-rings)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2237\" data-end=\"2261\"\u003e\u003cstrong data-start=\"2237\" data-end=\"2261\"\u003e10. Gas-Tight System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2262\" data-end=\"2434\"\u003e\n\u003cli data-section-id=\"1bs4qys\" data-start=\"2262\" data-end=\"2313\"\u003ePrevents contamination from oxygen and moisture\u003c\/li\u003e\n\u003cli data-section-id=\"aoyg3p\" data-start=\"2314\" data-end=\"2379\"\u003eSupports inert gas purging via external electrolyte reservoir\u003c\/li\u003e\n\u003cli data-section-id=\"1b2ap5q\" data-start=\"2380\" data-end=\"2434\"\u003eSuitable for sensitive electrochemical experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Note\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003eThis cell can be used to track kinetic phenomena such as the near-surface proton concentration changes during oxidation and reduction reaction at working electrode. It can be also used to identify materials such as carbon, metal oxides, polymers and electrolytes, and to determine their structure and distribution. Various metals are suitable for this cell as auxiliary electrode including Platinum, Gold and Silver. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe use of \u003c\/span\u003e\u003cspan\u003eRaman Electrochemical Flow H-Cell\u003c\/span\u003e\u003cspan\u003e with an ion-exchange membrane provides a more controlled and reliable platform for studying electrocatalysis, allowing researchers to investigate fundamental mechanisms and optimize catalytic performance with greater precision. For troubleshooting instruction see the \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/redox.me\/blogs\/good-measurement-practices\/troubleshooting-electrochemical-cell\"\u003eredox.me blog post\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSpecification \u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Exposure Area\u003c\/td\u003e\n\u003ctd\u003e3.5 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrolyte Volume\u003c\/td\u003e\n\u003ctd\u003e4.5 mL (WE) + 2 mL (CE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Path (incl. Sapphire Window)\u003c\/td\u003e\n\u003ctd\u003e3.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Plug Diameter\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane Size\u003c\/td\u003e\n\u003ctd\u003e20 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct includes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e1 x working electrode compartment\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/reference-electrodes\/products\/silver-silver-chloride-reference-electrode-ag-agcl-30mm\" target=\"_blank\"\u003eAg\/AgCl\u003c\/a\u003e\u003cspan\u003e or \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/reference-electrodes\/products\/silver-silver-ion-reference-electrode-70-mm\"\u003enon-aqueous\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAg\/Ag+\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 30 mm reference electrode\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"metal wire electrode platinum\" href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\/products\/metal-wire-auxiliary-electrode-35hx15-0-6-235-mm?variant=43339489312989\" target=\"_blank\"\u003eMetal wire electrode 35HX15 0.6\/235 MM, Platinum\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e1 x \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/redox.me\/products\/spectroscopic-window?_pos=2\u0026amp;_sid=d4a225d84\u0026amp;_ss=r\u0026amp;variant=40702466523290\" target=\"_blank\"\u003e\u003cspan\u003eS\u003c\/span\u003e\u003cspan\u003eapphire \u003c\/span\u003ewindow\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e1 x lid\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x lid pressing metal frame\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x WE Tantalum contact\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x sample holder\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x counter electrode compartment\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 x \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/accessories\/products\/plug-6-20-mm\" target=\"_blank\"\u003eplug\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMSE offers a range of electrochemical cells. Please \u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e for more information.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Redox.me","offers":[{"title":"Default Title","offer_id":41356031688762,"sku":"C-A-R_SM_ECF_HC","price":9401.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/C-A-R_MM_ECF_HC_1_689237d1-e905-4b89-8a08-db22143bf446.png?v=1775840173","url":"https:\/\/www.msesupplies.com\/products\/aqueous-compatible-screw-mount-raman-electrochemical-flow-h-cell-for-sample-size-23-mm-x-23-mm","provider":"MSE Supplies","version":"1.0","type":"link"}