{"product_id":"6-mm-dia-saturated-calomel-non-refillable-reference-electrode-70mm-long-1","title":"6 mm Dia. Saturated Calomel Non-Refillable Reference Electrode, 70mm long","description":"\u003ch2\u003e6 mm Dia. Saturated Calomel Non-Refillable Reference Electrode, 70mm long\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"0\"\u003eIntroduction\u003c\/h3\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe Saturated Calomel Non-Refillable Reference Electrode offers a standard of excellence for researchers requiring high precision and long-term stability in electrochemical measurements. Renowned for their exceptional reproducibility, these electrodes provide a dependable reference point across a diverse range of experimental conditions. \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0,0\"\u003eExceptional Long-Term Stability:\u003c\/b\u003e Mercury-based systems are prized for their consistent potential over time, ensuring that longitudinal data remains accurate and reproducible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0\"\u003eWide Potential Range:\u003c\/b\u003e Offers a broad operating window, allowing researchers to explore a wide spectrum of electrochemical processes without compromising reference integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,3,0\"\u003eLow Oxygen Sensitivity:\u003c\/b\u003e These electrodes are significantly less susceptible to interference from dissolved oxygen compared to alternative reference systems, a critical advantage for oxygen-sensitive or anaerobic experiments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,4,0\"\u003eReliable Performance:\u003c\/b\u003e Designed to minimize drift, providing a \"gold standard\" reference point that maintains accuracy even under demanding experimental protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Note\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003eThe reference electrode should be stored with the rubber plug applied on the tip. Please see the complete instructions \u003ca rel=\"noopener\" href=\"https:\/\/new.getgobot.com\/kb\/-N6WaqLr3RVPuFawUZUu\/a\/-N6WeBax00hCNejwQedh\" target=\"_blank\"\u003ehere\u003c\/a\u003e. Keeping in the electrolyte may shorten its lifetime; the electrode operates well as long as there is at least ¼ of the solution in the electrode tube. Before use, rinse it with deionized water. If air bubbles are present around the porous frit, flick the tip several times to remove them. For cleaning, use detergent, alcohols or acetone and rinse it with deionized water. This reference electrode cannot be re-filled.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eDespite mercury-based reference electrode advantages, it's essential to note that the use of mercury-based reference electrodes has raised environmental concerns due to the toxicity of mercury. Please use it responsibly to prevent environmental contamination and harm to human health. When it is no longer suitable for use, dispose according to local regulations. Always prioritize safety and seek guidance from appropriate authorities to ensure the responsible and environmentally friendly disposal of mercury-containing items.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"1\" style=\"width: 99.9394%; height: 208.324px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5928px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 19.5928px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 19.5928px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5928px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,1,0,0\"\u003e\u003cb data-path-to-node=\"1,1,0,0\" data-index-in-node=\"0\"\u003eEffective Length\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,1,1,0\"\u003e70 mm \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5928px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,2,0,0\"\u003e\u003cb data-path-to-node=\"1,2,0,0\" data-index-in-node=\"0\"\u003eTube Diameter\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,2,1,0\"\u003e6 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 90.767px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 90.767px;\"\u003e\u003cspan data-path-to-node=\"1,3,0,0\"\u003e\u003cb data-path-to-node=\"1,3,0,0\" data-index-in-node=\"0\"\u003eFilling Solution\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 90.767px;\"\u003e\n\u003cp data-path-to-node=\"1,3,1,2\"\u003e \u003c\/p\u003e\n\u003cp data-path-to-node=\"1,3,1,0\"\u003e\u003cb data-path-to-node=\"1,3,1,0\" data-index-in-node=\"0\"\u003eSCE:\u003c\/b\u003e 3 M KCl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5928px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,4,0,0\"\u003e\u003cb data-path-to-node=\"1,4,0,0\" data-index-in-node=\"0\"\u003ePotential Stability\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,4,1,0\"\u003e\u0026lt; 5 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5928px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,5,0,0\"\u003e\u003cb data-path-to-node=\"1,5,0,0\" data-index-in-node=\"0\"\u003eFrit Resistance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,5,1,0\"\u003e2–10 kΩ at room temperature (RT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5928px;\"\u003e\n\u003ctd style=\"width: 34.8077%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,5,0,0\"\u003e\u003cb data-path-to-node=\"1,5,0,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.6704%; height: 19.5928px;\"\u003e\u003cspan data-path-to-node=\"1,5,1,0\"\u003e\u003cspan\u003e0-100 °C\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Includes\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1x  non-refillable reference electrode\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1x rubber cup\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1x O-ring\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1x glass tube for storing purposes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMSE offers a range of electrodes. Please \u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e for more information.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Redox.me","offers":[{"title":"Default Title","offer_id":41364272873530,"sku":"E-Hg\/Hg2Cl2_70","price":459.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/E-HgHgO_70_aa463c5c-9e31-4448-92a2-26322b8c919f.png?v=1776373736","url":"https:\/\/www.msesupplies.com\/products\/6-mm-dia-saturated-calomel-non-refillable-reference-electrode-70mm-long-1","provider":"MSE Supplies","version":"1.0","type":"link"}