{"product_id":"purionx-aem-standard-kit","title":"PurionX AEM Standard Kit","description":"\u003ch2\u003ePurionX AEM Standard Kit\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eIntroduction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PurionX AEM Beginner Kit is designed for researchers who want to evaluate multiple high-performance anion exchange membranes in early-stage testing and material screening. This kit includes three PurionX AEM membrane samples with different thicknesses, counter ions, conductivity ranges, mechanical properties, and stability performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEach membrane is supplied in a 20 x 20 mm size, making this kit suitable for preliminary testing, membrane comparison, electrochemical evaluation, alkaline stability studies, and anion exchange membrane research.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKit Includes\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable height=\"66\" style=\"width: 50.6419%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.1499%;\"\u003e\u003cspan\u003ePurionX-111\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 15.4621%;\"\u003e\u003cspan\u003e1 pc\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.8127%;\"\u003e\u003cspan\u003e20 x 20 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.1499%;\"\u003e\u003cspan\u003ePurionX-142\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 15.4621%;\"\u003e\u003cspan\u003e1 pc\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.8127%;\"\u003e\u003cspan\u003e20 x 20 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.1499%;\"\u003e\u003cspan\u003ePurionX-181\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 15.4621%;\"\u003e\u003cspan\u003e1 pc\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.8127%;\"\u003e\u003cspan\u003e20 x 20 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAnion exchange membrane research\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAlkaline water electrolysis research\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFuel cell membrane evaluation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrochemical cell testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMembrane conductivity comparison\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIon exchange membrane screening\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAcademic and industrial R\u0026amp;D\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMembrane Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnion Exchange Membrane\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnion Exchange Membrane\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnion Exchange Membrane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAppearance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClear, Semi-Transparent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClear, Semi-Transparent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClear, Semi-Transparent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCounter Ion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHydroxide (OH⁻)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChloride (Cl⁻)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChloride (Cl⁻)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThickness, dry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–55 μm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80–85 μm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–13 μm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOH⁻ Conductivity at 23.0 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e38–45 mS\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–50 mS\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35–45 mS\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight per Unit Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0–4.3 mg\/cm²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.7–7.1 mg\/cm²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2–1.4 mg\/cm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIon Exchange Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2–2.5 meq\/g\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2–2.5 meq\/g\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2–2.5 meq\/g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensile Strength at 23.0 °C, 50% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e145–160 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eYoung’s Modulus at 23.0 °C, 50% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500–2000 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500–2000 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500–2000 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElongation at Break at 23.0 °C, 50% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–24%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–40%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–60%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensional Swelling in H₂O at 23.0 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;10%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;8%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWater Uptake at 23.0 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–60%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55–65%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–55%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlkaline Stability in 1 M KOH at 80 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;15,000 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;30,000 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;15,000 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOxidation Stability in Fenton’s Test at 80 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;36 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;72 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;24 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eImage is for reference only. Actual membrane appearance may vary slightly depending on storage condition, hydration state, packaging, and lighting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor best performance, users should follow proper membrane handling, storage, activation, and testing procedures based on their specific application and cell configuration.\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies LLC","offers":[{"title":"Default Title","offer_id":41487065841722,"sku":"ME0073613","price":375.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/ME0073611_7f20ad4b-b5da-4012-86c3-69a2a024726e.jpg?v=1782341868","url":"https:\/\/www.msesupplies.com\/en-gb\/products\/purionx-aem-standard-kit","provider":"MSE Supplies","version":"1.0","type":"link"}