{"product_id":"mse-pro-dilatometer-thermal-expansion-coefficient-analyzer-with-1700-max-furnace-temperature","title":"MSE PRO Dilatometer (Thermal expansion coefficient Analyzer) with 1700℃ Max Furnace Temperature","description":"\u003cdiv class=\"\" data-turn-id-container=\"request-69d92b15-79a0-83e8-a297-e7d0b6bd57ca-17\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69d92b15-79a0-83e8-a297-e7d0b6bd57ca-17\" data-testid=\"conversation-turn-265\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"4a8da1e7-4e8f-4ac7-837b-842724600481\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-4-thinking\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1i96uec\" data-start=\"0\" data-end=\"98\"\u003eMSE PRO Dilatometer (Thermal Expansion Coefficient Analyzer) with 1700℃ Max Furnace Temperature\u003c\/h2\u003e\n\u003ch3 data-section-id=\"zamd46\" data-start=\"100\" data-end=\"116\"\u003eIntroduction\u003c\/h3\u003e\n\u003cp data-start=\"118\" data-end=\"588\"\u003eThe \u003cstrong data-start=\"122\" data-end=\"221\"\u003eMSE PRO Dilatometer (Thermal Expansion Coefficient Analyzer) with 1700℃ Max Furnace Temperature\u003c\/strong\u003e is designed for analyzing the high-temperature expansion behavior of solid inorganic and metallic materials. It is suitable for materials such as alumina, refractory materials, precision-casting shells and cores, ceramics, ceramic raw materials, clay bodies, glazes, glass, graphite, carbon products, and various metal products.\u003c\/p\u003e\n\u003cp data-start=\"590\" data-end=\"1067\"\u003eThis instrument can measure and analyze linear change, linear expansion coefficient, volumetric expansion coefficient, rapid heating expansion, softening temperature, sintering kinetics, glass transition temperature, phase transitions, density changes, and rate-controlled sintering (RCS), along with their corresponding change curves. It is a versatile solution for materials research, quality control, and thermal expansion analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1069\" data-end=\"1085\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1087\" data-end=\"1838\"\u003e\n\u003cli data-section-id=\"10wc03j\" data-start=\"1087\" data-end=\"1132\"\u003eMaximum furnace temperature up to 1700℃\u003c\/li\u003e\n\u003cli data-section-id=\"1tftpdv\" data-start=\"1133\" data-end=\"1186\"\u003eSuitable for solid inorganic and metallic materials\u003c\/li\u003e\n\u003cli data-section-id=\"1d1gqp7\" data-start=\"1187\" data-end=\"1256\"\u003eMeasures linear expansion and thermal expansion coefficient\u003c\/li\u003e\n\u003cli data-section-id=\"183fsni\" data-start=\"1257\" data-end=\"1313\"\u003eSupports volumetric expansion coefficient analysis\u003c\/li\u003e\n\u003cli data-section-id=\"2n1se8\" data-start=\"1314\" data-end=\"1362\"\u003eCapable of rapid heating expansion testing\u003c\/li\u003e\n\u003cli data-section-id=\"1ik0s3e\" data-start=\"1363\" data-end=\"1442\"\u003eHelps evaluate softening temperature and glass transition temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1xinbhv\" data-start=\"1443\" data-end=\"1506\"\u003eSupports phase transition and density change analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1udsgq2\" data-start=\"1507\" data-end=\"1588\"\u003eEnables sintering kinetics research and rate-controlled sintering (RCS)\u003c\/li\u003e\n\u003cli data-section-id=\"ugf410\" data-start=\"1589\" data-end=\"1626\"\u003eComputer-controlled heating program\u003c\/li\u003e\n\u003cli data-section-id=\"ode4a6\" data-start=\"1627\" data-end=\"1689\"\u003eAutomatic calculation, data recording, storage, and printing\u003c\/li\u003e\n\u003cli data-section-id=\"opdyfw\" data-start=\"1690\" data-end=\"1838\"\u003eHigh-precision optical grating sensor for accurate expansion detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1840\" data-end=\"1856\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"1858\" data-end=\"1899\"\u003eThis dilatometer is suitable for testing:\u003c\/p\u003e\n\u003cul data-start=\"1901\" data-end=\"2126\"\u003e\n\u003cli data-section-id=\"1dbpijf\" data-start=\"1901\" data-end=\"1910\"\u003eAlumina\u003c\/li\u003e\n\u003cli data-section-id=\"z7xhj5\" data-start=\"1911\" data-end=\"1933\"\u003eRefractory materials\u003c\/li\u003e\n\u003cli data-section-id=\"1bbf3cl\" data-start=\"1934\" data-end=\"1970\"\u003ePrecision casting shells and cores\u003c\/li\u003e\n\u003cli data-section-id=\"a4439o\" data-start=\"1971\" data-end=\"2007\"\u003eCeramics and ceramic raw materials\u003c\/li\u003e\n\u003cli data-section-id=\"joun1g\" data-start=\"2008\" data-end=\"2032\"\u003eClay bodies and glazes\u003c\/li\u003e\n\u003cli data-section-id=\"1700qyq\" data-start=\"2033\" data-end=\"2040\"\u003eGlass\u003c\/li\u003e\n\u003cli data-section-id=\"vxth4s\" data-start=\"2041\" data-end=\"2071\"\u003eGraphite and carbon products\u003c\/li\u003e\n\u003cli data-section-id=\"15nlfzw\" data-start=\"2072\" data-end=\"2126\"\u003eMetal products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2128\" data-end=\"2141\"\u003eStandards\u003c\/h3\u003e\n\u003cp data-start=\"2143\" data-end=\"2202\"\u003eThis instrument is suitable for testing in accordance with:\u003c\/p\u003e\n\u003cul data-start=\"2204\" data-end=\"2677\"\u003e\n\u003cli data-section-id=\"1cwjses\" data-start=\"2204\" data-end=\"2291\"\u003eISO 10545-8:2014, ASTM C372-12 (2021), GB\/T 3810.8-2016 for ceramic tiles\u003c\/li\u003e\n\u003cli data-section-id=\"1vk2l6t\" data-start=\"2292\" data-end=\"2404\"\u003eISO 7991:1987, ASTM E228-17, GB\/T 16920 for the mean linear thermal expansion coefficient of glass\u003c\/li\u003e\n\u003cli data-section-id=\"1qt08me\" data-start=\"2405\" data-end=\"2512\"\u003eASTM E831-19, GB\/T 3074.4-2016 for the thermal expansion coefficient (CTE) of graphite electrodes\u003c\/li\u003e\n\u003cli data-section-id=\"m1xe6q\" data-start=\"2513\" data-end=\"2677\"\u003eASTM E228-17, NMPA drug packaging standards, and YBB 00202002\/3 for linear thermal expansion coefficient testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"2679\" data-end=\"2697\"\u003eSpecifications\u003c\/h3\u003e\n\u003ch4 data-start=\"2699\" data-end=\"2713\"\u003eDatasheet\u003c\/h4\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2715\" data-end=\"4267\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100.036%;\"\u003e\n\u003cthead data-start=\"2715\" data-end=\"2744\"\u003e\n\u003ctr data-start=\"2715\" data-end=\"2744\"\u003e\n\u003cth data-start=\"2715\" data-end=\"2727\" data-col-size=\"sm\" class=\"\" style=\"width: 37.1322%;\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2727\" data-end=\"2744\" data-col-size=\"lg\" class=\"\" style=\"width: 62.652%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2755\" data-end=\"4267\"\u003e\n\u003ctr data-start=\"2871\" data-end=\"2910\"\u003e\n\u003ctd data-start=\"2871\" data-end=\"2901\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eMaximum Furnace Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2901\" data-end=\"2910\" style=\"width: 62.652%;\"\u003e1700℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2960\" data-end=\"3027\"\u003e\n\u003ctd data-start=\"2960\" data-end=\"2975\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eHeating Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2975\" data-end=\"3027\" style=\"width: 62.652%;\"\u003e0–30°C\/min, adjustable, computer program control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3028\" data-end=\"3192\"\u003e\n\u003ctd data-start=\"3028\" data-end=\"3052\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eAutomatic Calculation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3052\" data-end=\"3192\" style=\"width: 62.652%;\"\u003eComputer automatically calculates expansion coefficient, volumetric expansion coefficient, linear expansion, and rapid heating expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3193\" data-end=\"3309\"\u003e\n\u003ctd data-start=\"3193\" data-end=\"3208\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eCompensation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3208\" data-end=\"3309\" style=\"width: 62.652%;\"\u003eAutomatic calculation and compensation of coefficient; online manual correction is also available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3310\" data-end=\"3426\"\u003e\n\u003ctd data-start=\"3310\" data-end=\"3326\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eData \u0026amp; Output\u003c\/td\u003e\n\u003ctd data-start=\"3326\" data-end=\"3426\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003eAutomatic data recording, storage, and printing; prints temperature-expansion coefficient curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3427\" data-end=\"3465\"\u003e\n\u003ctd data-start=\"3427\" data-end=\"3458\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eMinimum Temperature Interval\u003c\/td\u003e\n\u003ctd data-start=\"3458\" data-end=\"3465\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3466\" data-end=\"3507\"\u003e\n\u003ctd data-start=\"3466\" data-end=\"3496\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eExpansion Measurement Range\u003c\/td\u003e\n\u003ctd data-start=\"3496\" data-end=\"3507\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e12.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3508\" data-end=\"3541\"\u003e\n\u003ctd data-start=\"3508\" data-end=\"3531\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eExpansion Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3531\" data-end=\"3541\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e0.1 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3542\" data-end=\"3573\"\u003e\n\u003ctd data-start=\"3542\" data-end=\"3563\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eExpansion Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3563\" data-end=\"3573\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e0.2 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3574\" data-end=\"3610\"\u003e\n\u003ctd data-start=\"3574\" data-end=\"3591\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eCTE Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3591\" data-end=\"3610\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e0.001 × 10^-6\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3611\" data-end=\"3647\"\u003e\n\u003ctd data-start=\"3611\" data-end=\"3638\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eSystem Measurement Error\u003c\/td\u003e\n\u003ctd data-start=\"3638\" data-end=\"3647\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3648\" data-end=\"3707\"\u003e\n\u003ctd data-start=\"3648\" data-end=\"3674\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eSample Size (L × W × H)\u003c\/td\u003e\n\u003ctd data-start=\"3674\" data-end=\"3707\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e(2–15) × (2–15) × (20–150) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3708\" data-end=\"3761\"\u003e\n\u003ctd data-start=\"3708\" data-end=\"3723\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eSample Shape\u003c\/td\u003e\n\u003ctd data-start=\"3723\" data-end=\"3761\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003eSquare\/Circular samples acceptable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3762\" data-end=\"3923\"\u003e\n\u003ctd data-start=\"3762\" data-end=\"3784\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eTransmission System\u003c\/td\u003e\n\u003ctd data-start=\"3784\" data-end=\"3923\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003eImported linear ball bearings for friction-free transmission of expansion value, ensuring high transmission precision and repeatability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3924\" data-end=\"3958\"\u003e\n\u003ctd data-start=\"3924\" data-end=\"3939\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3939\" data-end=\"3958\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003e220V ±10%, 2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3959\" data-end=\"4141\"\u003e\n\u003ctd data-start=\"3959\" data-end=\"3980\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eControl \u0026amp; Software\u003c\/td\u003e\n\u003ctd data-start=\"3980\" data-end=\"4141\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003eEquipped with standard computer interface; connects to a standard PC; all operations are performed via the computer interface; full software package provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4142\" data-end=\"4267\"\u003e\n\u003ctd data-start=\"4142\" data-end=\"4163\" data-col-size=\"sm\" style=\"width: 37.1322%;\"\u003eMeasurement Sensor\u003c\/td\u003e\n\u003ctd data-start=\"4163\" data-end=\"4267\" data-col-size=\"lg\" style=\"width: 62.652%;\"\u003eHigh-precision optical grating sensor and data processing system for detecting expansion deformation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"4269\" data-end=\"4306\"\u003e \u003c\/p\u003e\n\u003ch3 data-section-id=\"1qab7wl\" data-start=\"4308\" data-end=\"4332\"\u003eControl and Software\u003c\/h3\u003e\n\u003cp data-start=\"4334\" data-end=\"4605\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe system is equipped with a standard computer interface and connects to a standard PC. All operations are performed through the computer interface, providing user-friendly control and full software support for testing and analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"MSE Supplies","offers":[{"title":"Default Title","offer_id":41369602981946,"sku":"MA0069432","price":22883.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MA0069424_ac081a35-619a-441a-9df1-787f437e6ccd.jpg?v=1777058270","url":"https:\/\/www.msesupplies.com\/en-gb\/products\/mse-pro-dilatometer-thermal-expansion-coefficient-analyzer-with-1700-max-furnace-temperature","provider":"MSE Supplies","version":"1.0","type":"link"}