{"product_id":"mse-pro-530pro-fourier-transform-infrared-ftir-spectrometer","title":"MSE PRO 530PRO Fourier Transform Infrared (FTIR) Spectrometer","description":"\u003ch2\u003eMSE PRO 530PRO Fourier Transform Infrared (FTIR) Spectrometer\u003c\/h2\u003e\n\u003ch3\u003eIntroduction\u003c\/h3\u003e\n\u003cp data-end=\"748\" data-start=\"64\"\u003eThe \u003cstrong\u003eMSE PRO 530PRO Fourier Transform Infrared (FTIR) Spectrometer\u003c\/strong\u003e is a high-performance Fourier Transform Infrared spectrometer designed for advanced laboratory analysis, routine quality control, and scientific research. Built on more than thirty years of FTIR development and manufacturing experience, the 530Pro  version combines intelligent operation, strong stability, and low maintenance requirements in one compact platform. It is well suited for applications such as battery materials analysis, materials science, pharmaceutical analysis, polymer characterization, food and beverage testing, and environmental studies.\u003c\/p\u003e\n\u003cp data-end=\"1255\" data-start=\"750\"\u003eThe system features a cube-corner Michelson interferometer, gold-coated reflecting mirrors, a modular cast-aluminum structure, and intelligent moisture-proof design to support long-term stability and reliable spectral performance. With Ethernet and WiFi communication, real-time instrument status monitoring, and a large sample chamber for accessory expansion, the DW-FTIR-530Pro is a flexible solution for modern FTIR workflows.\u003c\/p\u003e\n\u003ch3 data-end=\"1273\" data-start=\"1257\" data-section-id=\"1iz91iu\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-end=\"2320\" data-start=\"1275\"\u003e\n\u003cli data-end=\"1348\" data-start=\"1275\" data-section-id=\"efu9ts\"\u003eHigh-sensitivity FT-IR spectrometer for research and routine analysis\u003c\/li\u003e\n\u003cli data-end=\"1421\" data-start=\"1349\" data-section-id=\"giwiod\"\u003eCube-corner Michelson interferometer for long-term optical stability\u003c\/li\u003e\n\u003cli data-end=\"1466\" data-start=\"1422\" data-section-id=\"11k3rc6\"\u003eDLATGS detector for improved performance\u003c\/li\u003e\n\u003cli data-end=\"1517\" data-start=\"1467\" data-section-id=\"1hl4hsy\"\u003eSignal-to-noise ratio better than 40,000:1\u003c\/li\u003e\n\u003cli data-end=\"1559\" data-start=\"1518\" data-section-id=\"10iyjoe\"\u003eWavenumber range of 7800–350 cm⁻¹\u003c\/li\u003e\n\u003cli data-end=\"1591\" data-start=\"1560\" data-section-id=\"1ff6p9s\"\u003eResolution of 0.85 cm⁻¹\u003c\/li\u003e\n\u003cli data-end=\"1633\" data-start=\"1592\" data-section-id=\"97vkzc\"\u003eWavenumber accuracy of ±0.01 cm⁻¹\u003c\/li\u003e\n\u003cli data-end=\"1689\" data-start=\"1634\" data-section-id=\"18prizz\"\u003eHigh-intensity, long-lifetime, air-cooled IR source\u003c\/li\u003e\n\u003cli data-end=\"1759\" data-start=\"1690\" data-section-id=\"119ijyx\"\u003eReal-time instrument status, temperature, and humidity monitoring\u003c\/li\u003e\n\u003cli data-end=\"1806\" data-start=\"1760\" data-section-id=\"xy3hgv\"\u003eEthernet and WiFi dual communication modes\u003c\/li\u003e\n\u003cli data-end=\"1870\" data-start=\"1807\" data-section-id=\"j7infg\"\u003eMainFTOS Suite software workstation compatible with Windows\u003c\/li\u003e\n\u003cli data-end=\"1923\" data-start=\"1871\" data-section-id=\"1uq4u2r\"\u003eFDA 21 CFR Part 11 compliance software available\u003c\/li\u003e\n\u003cli data-end=\"2017\" data-start=\"1924\" data-section-id=\"1ssqyjs\"\u003eLarge sample chamber for ATR, liquid cell, reflectance, microscope, and other accessories\u003c\/li\u003e\n\u003cli data-end=\"2091\" data-start=\"2018\" data-section-id=\"1bfwbte\"\u003eIntelligent multi-sealed moisture-proof design for reliable operation\u003c\/li\u003e\n\u003cli data-end=\"2145\" data-start=\"2092\" data-section-id=\"13gvfph\"\u003eCE certified, with IQ\/OQ\/PQ available as optional\u003c\/li\u003e\n\u003cli data-end=\"2320\" data-start=\"2146\" data-section-id=\"a7wk39\"\u003eCompact benchtop design with broad accessory expandability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"2322\" data-end=\"2340\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2358\" data-end=\"4056\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100.036%;\"\u003e\n\u003cthead data-start=\"2358\" data-end=\"2398\"\u003e\n\u003ctr data-start=\"2358\" data-end=\"2398\"\u003e\n\u003cth data-start=\"2369\" data-end=\"2381\" data-col-size=\"sm\" class=\"\" style=\"width: 27.2945%;\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2381\" data-end=\"2398\" data-col-size=\"md\" class=\"\" style=\"width: 72.31%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2413\" data-end=\"4056\"\u003e\n\u003ctr data-start=\"2413\" data-end=\"2481\"\u003e\n\u003ctd data-start=\"2421\" data-end=\"2436\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"2436\" data-end=\"2481\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eMA0068422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2482\" data-end=\"2556\"\u003e\n\u003ctd data-start=\"2499\" data-end=\"2516\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eInterferometer\u003c\/td\u003e\n\u003ctd data-start=\"2516\" data-end=\"2556\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eCube-corner Michelson interferometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2557\" data-end=\"2618\"\u003e\n\u003ctd data-start=\"2574\" data-end=\"2590\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eBeam Splitter\u003c\/td\u003e\n\u003ctd data-start=\"2590\" data-end=\"2618\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eMultilayer Ge coated KBr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2619\" data-end=\"2660\"\u003e\n\u003ctd data-start=\"2630\" data-end=\"2650\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eStandard Detector\u003c\/td\u003e\n\u003ctd data-start=\"2650\" data-end=\"2660\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eDLATGS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2661\" data-end=\"2699\"\u003e\n\u003ctd data-start=\"2672\" data-end=\"2692\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eOptional Detector\u003c\/td\u003e\n\u003ctd data-start=\"2692\" data-end=\"2699\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eMCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2700\" data-end=\"2779\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2724\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eIR Source\u003c\/td\u003e\n\u003ctd data-start=\"2724\" data-end=\"2779\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eHigh intensity, long lifetime, air-cooled IR source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2780\" data-end=\"2839\"\u003e\n\u003ctd data-start=\"2803\" data-end=\"2822\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eWavenumber Range\u003c\/td\u003e\n\u003ctd data-start=\"2822\" data-end=\"2839\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003e7800–350 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2840\" data-end=\"2889\"\u003e\n\u003ctd data-start=\"2863\" data-end=\"2876\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2876\" data-end=\"2889\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003e0.85 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2890\" data-end=\"2949\"\u003e\n\u003ctd data-start=\"2913\" data-end=\"2935\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eWavenumber Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2935\" data-end=\"2949\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003e±0.01 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2950\" data-end=\"3021\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2997\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eSignal-to-Noise Ratio\u003c\/td\u003e\n\u003ctd data-start=\"2997\" data-end=\"3021\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eBetter than 40,000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3022\" data-end=\"3144\"\u003e\n\u003ctd data-start=\"3045\" data-end=\"3066\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eS\/N Test Condition\u003c\/td\u003e\n\u003ctd data-start=\"3066\" data-end=\"3144\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eRMS value, at 2100–2200 cm⁻¹, resolution: 4 cm⁻¹, 1 minute data collection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3145\" data-end=\"3237\"\u003e\n\u003ctd data-start=\"3157\" data-end=\"3174\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eScanning Speed\u003c\/td\u003e\n\u003ctd data-start=\"3174\" data-end=\"3237\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eMicroprocessor control, different scanning speed selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3238\" data-end=\"3349\"\u003e\n\u003ctd data-start=\"3249\" data-end=\"3269\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eStandard Software\u003c\/td\u003e\n\u003ctd data-start=\"3269\" data-end=\"3349\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eMainFTOS Suite software workstation, compatible with all Windows OS versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3350\" data-end=\"3423\"\u003e\n\u003ctd data-start=\"3361\" data-end=\"3381\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eOptional Software\u003c\/td\u003e\n\u003ctd data-start=\"3381\" data-end=\"3423\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eFDA 21 CFR Part 11 compliance software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3424\" data-end=\"3480\"\u003e\n\u003ctd data-start=\"3440\" data-end=\"3452\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"3452\" data-end=\"3480\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eEthernet \u0026amp; WiFi wireless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3481\" data-end=\"3565\"\u003e\n\u003ctd data-start=\"3497\" data-end=\"3511\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eData Output\u003c\/td\u003e\n\u003ctd data-start=\"3511\" data-end=\"3565\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eStandard data format, report generation and output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3566\" data-end=\"3683\"\u003e\n\u003ctd data-start=\"3580\" data-end=\"3599\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eStatus Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"3599\" data-end=\"3683\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003ePower-on self-check, real-time temperature and humidity monitoring and reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3684\" data-end=\"3741\"\u003e\n\u003ctd data-start=\"3700\" data-end=\"3716\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eCertification\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3716\" data-end=\"3741\" style=\"width: 72.31%;\"\u003eCE; IQ\/OQ\/PQ optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3742\" data-end=\"3783\"\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3756\" data-end=\"3770\" style=\"width: 27.2945%;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3770\" data-end=\"3783\" style=\"width: 72.31%;\"\u003e10°C–30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3784\" data-end=\"3826\"\u003e\n\u003ctd data-start=\"3798\" data-end=\"3809\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-start=\"3809\" data-end=\"3826\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eLess than 60%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3827\" data-end=\"3898\"\u003e\n\u003ctd data-start=\"3840\" data-end=\"3855\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3855\" data-end=\"3898\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003e\n\u003cp\u003eAC220V\/±22V, 50Hz\/±1Hz;\u003c\/p\u003e\n\u003cp\u003eAC110V, 60Hz optional\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3899\" data-end=\"3945\"\u003e\n\u003ctd data-start=\"3910\" data-end=\"3923\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"3923\" data-end=\"3945\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003e490 × 420 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3946\" data-end=\"3977\"\u003e\n\u003ctd data-start=\"3957\" data-end=\"3966\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3966\" data-end=\"3977\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003e23.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3978\" data-end=\"4056\"\u003e\n\u003ctd data-start=\"4003\" data-end=\"4026\" data-col-size=\"sm\" style=\"width: 27.2945%;\"\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd data-start=\"4026\" data-end=\"4056\" data-col-size=\"md\" style=\"width: 72.31%;\"\u003eTransmission sample holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMSE Offers a wide range of analytical instrument. Please \u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e for more information\u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"Default Title","offer_id":41360272228410,"sku":"MA0068422","price":38159.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MA0068421-1_3021e0f9-b725-4fae-bcb3-bb70e91819d8.jpg?v=1775843330","url":"https:\/\/www.msesupplies.com\/en-gb\/products\/mse-pro-530pro-fourier-transform-infrared-ftir-spectrometer","provider":"MSE Supplies","version":"1.0","type":"link"}