{"product_id":"ika-rotavisc-sbs-hi-vi-i-complete-viscometers","title":"IKA ROTAVISC SBS hi-vi I Complete Viscometers","description":"\u003ch2\u003eIKA ROTAVISC SBS hi-vi I Complete Viscometers\u003c\/h2\u003e\n\u003cp class=\"p\"\u003e\u003cspan\u003eBuy IKA products from MSE Supplies at the best value.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cb\u003e\u003cspan class=\"15\"\u003eMSE Supplies is an authorized distributor of IKA.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"p\"\u003e\n\u003cb\u003e\u003cspan class=\"15\"\u003eProduct Details\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan class=\"15\"\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003e\u003cspan class=\"15\"\u003eItem number:\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan class=\"15\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cstrong\u003e0010013820\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan\u003eThe SBS (Steel Ball Bearing, Suspended) rotational viscometers extend a large part of the application spectrum of our IKA ROTAVISC device family.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eInstead of a jewel bearing, these devices are equipped with a special ball bearing technology.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThey are characterized by their high robustness. Predestined for applications with very high sample throughput, frequent spindle changes, operation in harsher environments, or even frequently changeing device locations.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eWhether simple or demanding viscosity measurements - with ROTAVISC you get fast and accurate results.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEasy to use\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIntuitive menu navigation awaits you via the generous 4.3\"\" TFT display. A digital leveling also supports the correct setting of the starting condition. Recurring tasks are facilitated by the simple ramp function.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eHighest measurement accuracy\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe accuracy of the ROTAVISC rotary viscometers for Newtonian and non-Newtonian liquids is +\/- 1 % of the measuring range. The reproducibility is +\/- 0.2%.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eInfinitely variable speed\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eWith ROTAVISC you have a viscometer in which you can adjust the speed stepless, but also specify programs or individual speed levels.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eIKA ROTAVISC SBS hi-vi I Complete\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eViscosity measuring range: 200 - 80.000.000 mPas\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eScope of delivery\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eROTAVISC SBS hi-vi I control\u003c\/li\u003e\n\u003cli\u003eROTASTAND\u003c\/li\u003e\n\u003cli\u003eSP set-2\u003c\/li\u003e\n\u003cli\u003ePT 100.8\u003c\/li\u003e\n\u003cli\u003eGuard rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAbout IKA\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; line-height: 107%; font-family: 'Calibri',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003eFounded in 1910 as a supplier for pharmacies and hospitals, the company left bombed-out Cologne for Staufen im Breisgau in 1942. There it quickly became the world's leading company for laboratory technology as well as dispersing, stirring and kneading machines.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"ika-flex-table-header\"\u003eTechnical Data of IKA ROTAVISC SBS hi-vi I Complete Viscometers\u003c\/h3\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eViscosity Measuring Range\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e80000000 mPas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eViscosity Accuracy (FSR)\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eViscosity Repeatibility (FSR)\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e0.2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSpring torque\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e1.4374 mNm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eGuard rail\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eme-vi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eMeasuring spindle series\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSP set-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eMotor rating output\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e4.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eDirection of rotation\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eright\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSpeed display\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSpeed range\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e0.01 - 200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSetting accuracy speed\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e±0.01 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSpeed adjustment\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTorque display\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTorque measurement\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTimer\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTimer display\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTime setting range\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e0.017 - 6000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTemperature measurement resolution\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eWorking temperature display\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eConnection for ext. temperature sensor\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePT 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eGraph function\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eOperating mode\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003etimer and continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eCalibration option\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTouch function\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePemitted density\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e9999 kg\/dm3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eWorking temperature\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e-100 - 300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eFastening on stand\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eextension arm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eSupport rod diameter (with integrated fastening on stand)\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eTelescope stand stroke\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePlug-in coupling (Ø)\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eBasic container volume\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e600 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eStand\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eRotastand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eStroke max.\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eDiameter\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eDynamic load\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e351 x 629 x 372 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e7.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eUSB interface\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eMicro-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePower input\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003ePower input standby\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e0.06 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eDC Voltage\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e24 V=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ika-flex-table-row\"\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd class=\"ika-flex-table-column\"\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":40746926440506,"sku":"0010013820","price":5198.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/0010013820.jpg?v=1735308076","url":"https:\/\/www.msesupplies.com\/en-gb\/products\/ika-rotavisc-sbs-hi-vi-i-complete-viscometers","provider":"MSE Supplies","version":"1.0","type":"link"}