{"product_id":"elveflow-flow-sensor-2-digital","title":"ELVEFLOW Flow Sensor 2 Digital","description":"\u003ch2\u003eELVEFLOW Flow Sensor 2 Digital\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan data-mce-style=\"color: rgb(255, 42, 0);\"\u003eBuy ELVEFLOW products from MSE Supplies at the best value.\u003c\/span\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\" data-mce-style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-mce-style=\"color: rgb(0, 0, 0);\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eMicrofluidic flow sensor\u003c\/p\u003e\n\u003cp\u003eWorking range from 0 to 7 µL\/min with aqueous solutions\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with OB1 MKIII+ and Sensor Reader v2 only\u003c\/li\u003e\n\u003cli\u003eElveflow® Smart Interface software included. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComes with 6-40 to 1\/4-28\" adapters.\u003c\/p\u003e\n\u003cp\u003e\/! Without 1\/4-28\" fittings \/!\u003c\/p\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003cp\u003eElveflow’s\u003cspan\u003e \u003c\/span\u003eMicrofluidic Flow Rate Sensor\u003cspan\u003e \u003c\/span\u003euses thermal time-of-flight technology to flow rates in micro-size channels. Its features make it a robust, reliable and affordable solution for microfluidic applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5 sensors covering water flow rates from 0.07 to 5000 µL\/min\u003c\/li\u003e\n\u003cli\u003e5% accuracy on most of the operating range\u003c\/li\u003e\n\u003cli\u003eFully compatible with other instruments from the Elveflow range (MSR\u003ca href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-measurement-sensors\/microfluidic-sensor-reader\/\" rel=\"noopener\" target=\"_blank\" data-mce-href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-measurement-sensors\/microfluidic-sensor-reader\/\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/a\u003eSensor reader and Flow Controllers – OB1,\u003cspan\u003e \u003c\/span\u003eCobalt\u003cspan\u003e \u003c\/span\u003e-)\u003c\/li\u003e\n\u003cli\u003eNon-invasive measurements\u003c\/li\u003e\n\u003cli\u003eHigh chemical compatibility: wetted parts made of PEEK and glass\u003c\/li\u003e\n\u003cli\u003eLow dead volume down to 1 μL\u003c\/li\u003e\n\u003cli\u003eBi-directional flow rate measurement (positive \u0026amp; negative)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eFlow Rate Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003cp\u003eYou can achieve flow control of your experiment by combining any Microfluidic Flow Sensor with our pressure controller systems (OB1 MK4,\u003cspan\u003e \u003c\/span\u003eCobalt\u003ca href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-control-systems\/autonomous-vacuum-pressure-pumps\/\" data-mce-href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-control-systems\/autonomous-vacuum-pressure-pumps\/\"\u003e\u003c\/a\u003e). The Elveflow\u003cspan\u003e \u003c\/span\u003eESI software automatically adjusts the pressure to reach the required flow rate.\u003c\/p\u003e\n\u003cp\u003eResearchers who want to monitor the flow rate of a third party instrument like a syringe pump can plug the flow sensor to our Microfluidic Sensor Reader (MSR).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSmooth, Pulseless Flow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll our flow controller systems (\u003ca href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-control-systems\/ob1-pressure-controller\/\" rel=\"noopener\" target=\"_blank\" data-mce-href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-control-systems\/ob1-pressure-controller\/\"\u003e\u003c\/a\u003eOB1 MK4,\u003cspan\u003e \u003c\/span\u003eCobalt) can be coupled with the\u003cspan\u003e \u003c\/span\u003eMicrofluidic Flow Rate Sensor. Using the feedback loop control of our \u003ca href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-software\/elveflow-software-sdk\/\" rel=\"noopener\" target=\"_blank\" data-mce-href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-software\/elveflow-software-sdk\/\"\u003e\u003c\/a\u003eESI\u003cspan\u003e \u003c\/span\u003esoftware, you can accurately monitor and control flow rates in your microfluidic setup in a stable, pulseless and responsive fashion. Directly input the flow rate into the software to reach the requested value.\u003c\/p\u003e\n\u003cp\u003eThe microfluidic flow sensors can be plugged anywhere inline in your microfluidic setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich Flow Sensor to Choose?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eElveflow offers 5 different flow rate sensors (+1 Coriolis\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-measurement-sensors\/microfluidic-flow-sensor-coriolis\/\" data-mce-href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-measurement-sensors\/microfluidic-flow-sensor-coriolis\/\"\u003e\u003c\/a\u003eBronkhorst Flow Sensor) that are each accurate and precise in a given range.\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eUse our explanatory range and accuracy chart in order to choose the most fitting Flow Sensor for your application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNote: Please note that the range may change depending on fluid properties (thermal conductivity, density and thermal capacity ,…etc.).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSensor Reading Module\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003eSensor Reader\u003cspan\u003e \u003c\/span\u003eis a device specifically designed to be used with all of Elveflow’s sensors. The reader allows to use Elveflow Sensors with any third party instrument used to drive liquid (syringe pump, peristaltic pump, perfusion, pressure controller).\u003c\/p\u003e\n\u003ch3\u003eThermal Time-of-flight or Coriolis Based Sensor?\u003c\/h3\u003e\n\u003cp\u003eElveflow offers two types of flow rate sensors: one based on the thermal conductivity technology (Microfluidic Flow Sensor) and one based on the Coriolis principle (Bronkhorst Flow Sensor\u003ca href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-measurement-sensors\/microfluidic-flow-sensor-coriolis\/\" data-mce-href=\"https:\/\/www.elveflow.com\/microfluidic-products\/microfluidics-flow-measurement-sensors\/microfluidic-flow-sensor-coriolis\/\"\u003e\u003c\/a\u003e). Both sensors have pros and cons that have been summarized in the table below. This table helps you choose your sensors depending on your application and your budget.\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 495pt; height: 365.05px;\" width=\"660\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 6229; width: 131pt;\" width=\"175\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 8561; width: 181pt;\" width=\"241\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 8675; width: 183pt;\" width=\"244\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 131pt;\" width=\"175\" class=\"xl65\" height=\"19\"\u003eFlow Sensors Comparison\u003c\/td\u003e\n\u003ctd style=\"width: 181pt; height: 19.6px;\" width=\"241\" class=\"xl65\"\u003eBFS\u003c\/td\u003e\n\u003ctd style=\"width: 183pt; height: 19.6px;\" width=\"244\" class=\"xl65\"\u003eMFS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6625px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\" height=\"22\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003e0.2 % of measured \u003cspan class=\"font5\"\u003e\u003csup\u003e(1)\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003e0.5 % of measured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\" height=\"19\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\"\u003eOne sensor for 1.6 µl\/min to 3 mL\/min\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\"\u003eFive sensor from 10nL\/min to 5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003eNegative flow measurement\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003eSupported fluid types\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eAll without calibration\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eAll without calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6625px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\" height=\"22\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003e35 ms \u003cspan class=\"font5\"\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003eFrom 1 to 70 ms \u003cspan class=\"font5\"\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003eFlow sensor size\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003e65 x 32 x 144 mm\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003e58 x 53 x 23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6625px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\" height=\"22\"\u003eInternal diameter\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003e250 µm\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003eFrom 250 µm to 1.8 mm \u003cspan class=\"font5\"\u003e\u003csup\u003e(4)\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003e3 kg\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003e1\/16* OD tubing\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003e1\/16* OD tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6625px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\" height=\"22\"\u003eInternal volume\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003e13 µL\u003c\/td\u003e\n\u003ctd style=\"height: 22.6625px;\" class=\"xl65\"\u003eFrom 1 µL to 80 µL \u003cspan class=\"font5\"\u003e\u003csup\u003e(4)\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003eWetted material\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eStainless steel 316L or comparable\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eSilicium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\" height=\"19\"\u003ePrincipal\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eCoriolis\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\" class=\"xl65\"\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\" height=\"38\"\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\" height=\"38\"\u003eComputer connection\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\"\u003eDirectly via USB to the computer\u003c\/td\u003e\n\u003ctd style=\"width: 183pt; height: 39.2px;\" width=\"244\" class=\"xl67\"\u003eDirectly on the OB1 and the AF1 or with the Sensor reader MSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\" height=\"19\"\u003eAdditional features\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl65\"\u003eTemperature and density measurement\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\" class=\"xl66\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e(1) Available upon request. 2 % accuracy for the regular model\u003cbr\u003e(2) 0.2 s at 98% (spec) to fill the tubing then 35 ms with temperature measurement\u003cbr\u003e(3) Depending on chosen digital resolution\u003cbr\u003e(4) Depending of the sensor range\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wpb_text_column wpb_content_element\"\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-mce-style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eElveflow offers a selection of 5 different Microfluidic Flow Rate Sensors that vary by the covered flow rate range. Below, are summarized the different specifications for each sensor:\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"1191\" width=\"1040\" src=\"https:\/\/www.elveflow.com\/wp-content\/uploads\/2019\/11\/XX_MFS_Standard_flow_rate_sensor_technical_specifications_ELVEFLOW_MICROFLUIDICS.jpg\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"ELVEFLOW","offers":[{"title":"Default Title","offer_id":40561334222906,"sku":"MFS-D-2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Microfluidicflowsensor-MFS.jpg?v=1721998676","url":"https:\/\/www.msesupplies.com\/en-gb\/products\/elveflow-flow-sensor-2-digital","provider":"MSE Supplies","version":"1.0","type":"link"}