{"product_id":"d-xylose-colorimetric-assay-kit","title":"D-Xylose Colorimetric Assay Kit","description":"\u003ch2\u003eD-Xylose Colorimetric Assay Kit\u003c\/h2\u003e\n\u003ctable style=\"height: 48px; width: 554px;\" width=\"503\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px; width: 243.175px;\" data-mce-style=\"height: 10px; width: 243.175px;\"\u003e\u003cstrong\u003eSKU #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px; width: 297.225px;\" data-mce-style=\"height: 10px; width: 297.225px;\"\u003eE-BC-K018-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 243.175px;\" data-mce-style=\"height: 19px; width: 243.175px;\"\u003e\u003cstrong\u003eDetection Instrument\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19px; width: 297.225px;\" data-mce-style=\"height: 19px; width: 297.225px;\"\u003eSpectrophotometer(554 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 243.175px;\" data-mce-style=\"height: 19px; width: 243.175px;\"\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 297.225px; height: 19px;\" data-mce-style=\"width: 297.225px; height: 19px;\"\u003e\u003cspan\u003eColorimetric method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eProduct Details\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eProperties\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable style=\"font-size: 0.875rem; height: 298px; width: 555px;\" class=\"dtl_table2\" data-mce-style=\"font-size: 0.875rem; height: 298px; width: 555px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 19px;\" data-mce-style=\"width: 163.788px; height: 19px;\"\u003e\u003cspan\u003eSynonyms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e\u003cspan\u003eD-aldopentose\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 163.788px;\" data-mce-style=\"height: 19px; width: 163.788px;\"\u003eSample Type\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e\u003cspan\u003eSerum, plasma, urine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 19px;\" data-mce-style=\"width: 163.788px; height: 19px;\"\u003e\u003cspan\u003eSensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e\u003cspan\u003e0.007 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 19px;\" data-mce-style=\"width: 163.788px; height: 19px;\"\u003e\u003cspan\u003eDetection Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e\u003cspan\u003e0.007-4 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 19px;\" data-mce-style=\"width: 163.788px; height: 19px;\"\u003e\u003cspan\u003eDetection Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e\u003cspan\u003eColorimetric method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 19px;\" data-mce-style=\"width: 163.788px; height: 19px;\"\u003e\u003cspan\u003eAssay type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eQuantitative\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 19px;\" data-mce-style=\"width: 163.788px; height: 19px;\"\u003e\u003cspan\u003eAssay time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 10px;\" data-mce-style=\"width: 163.788px; height: 10px;\"\u003e\u003cspan\u003ePrecision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 10px;\" data-mce-style=\"width: 377.612px; height: 10px;\"\u003eAverage inter-assay CV: 4.500% | Average intra-assay CV: 2.200%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 46px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 46px;\" data-mce-style=\"width: 163.788px; height: 46px;\"\u003e\u003cspan\u003eOther instruments required\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 46px;\" data-mce-style=\"width: 377.612px; height: 46px;\"\u003e\u003cspan\u003eMicropipettor, Vortex mixer, Water bath\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 163.788px; height: 22px;\" data-mce-style=\"width: 163.788px; height: 22px;\"\u003e\u003cspan\u003eOther reagents required\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 22px;\" data-mce-style=\"width: 377.612px; height: 22px;\"\u003e\u003cspan\u003eNormal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px; width: 163.788px;\" data-mce-style=\"height: 10px; width: 163.788px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 10px;\" data-mce-style=\"width: 377.612px; height: 10px;\"\u003e\u003cspan\u003e2-8℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"height: 19px; width: 163.788px;\" data-mce-style=\"height: 19px; width: 163.788px;\"\u003eValid period\u003c\/td\u003e\n\u003ctd style=\"width: 377.612px; height: 19px;\" data-mce-style=\"width: 377.612px; height: 19px;\"\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"font-size: 0.875rem;\"\u003eDetection Principle\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eD-xylose can produce furfural by dehydration in strong acid solution. The generated furfural reacts with Phloroglucinol to form pink compounds. The content of D-xylose can be calculated by colorimetric assay at 554 nm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eKit Components \u0026amp; Storage\u003c\/strong\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"607\" style=\"height: 136px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39px;\"\u003e\n\u003ctd style=\"width: 65.225px; height: 39px;\" data-mce-style=\"width: 65.225px; height: 39px;\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 122.4px; height: 39px;\" data-mce-style=\"width: 122.4px; height: 39px;\"\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 104.35px; height: 39px;\" data-mce-style=\"width: 104.35px; height: 39px;\"\u003e\n\u003cstrong\u003eSize 1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(50 assays)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 108.375px; height: 39px;\" data-mce-style=\"width: 108.375px; height: 39px;\"\u003e\n\u003cstrong\u003eSize 2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(100 assays)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 118.45px; height: 39px;\" data-mce-style=\"width: 118.45px; height: 39px;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39px;\"\u003e\n\u003ctd style=\"width: 65.225px; height: 39px;\" data-mce-style=\"width: 65.225px; height: 39px;\"\u003eReagent 1\u003c\/td\u003e\n\u003ctd style=\"width: 122.4px; height: 39px;\" data-mce-style=\"width: 122.4px; height: 39px;\"\u003ePhloroglucinol\u003c\/td\u003e\n\u003ctd style=\"width: 104.35px; height: 39px;\" data-mce-style=\"width: 104.35px; height: 39px;\"\u003e60 mL × 3 vials\u003c\/td\u003e\n\u003ctd style=\"width: 108.375px; height: 39px;\" data-mce-style=\"width: 108.375px; height: 39px;\"\u003e60 mL × 6 vials\u003c\/td\u003e\n\u003ctd style=\"width: 118.45px; height: 39px;\" data-mce-style=\"width: 118.45px; height: 39px;\"\u003e2-8℃, 12 months shading light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39px;\"\u003e\n\u003ctd style=\"width: 65.225px; height: 39px;\" data-mce-style=\"width: 65.225px; height: 39px;\"\u003eReagent 2\u003c\/td\u003e\n\u003ctd style=\"width: 122.4px; height: 39px;\" data-mce-style=\"width: 122.4px; height: 39px;\"\u003e13.3 mmol\/L D-Xylose Standard\u003c\/td\u003e\n\u003ctd style=\"width: 104.35px; height: 39px;\" data-mce-style=\"width: 104.35px; height: 39px;\"\u003e1 mL × 1 vial\u003c\/td\u003e\n\u003ctd style=\"width: 108.375px; height: 39px;\" data-mce-style=\"width: 108.375px; height: 39px;\"\u003e1 mL × 1 vial\u003c\/td\u003e\n\u003ctd style=\"width: 118.45px; height: 39px;\" data-mce-style=\"width: 118.45px; height: 39px;\"\u003e2-8℃, 12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 65.225px; height: 19px;\" data-mce-style=\"width: 65.225px; height: 19px;\"\u003eReagent 3\u003c\/td\u003e\n\u003ctd style=\"width: 122.4px; height: 19px;\" data-mce-style=\"width: 122.4px; height: 19px;\"\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd style=\"width: 104.35px; height: 19px;\" data-mce-style=\"width: 104.35px; height: 19px;\"\u003e10 mL × 1 vial\u003c\/td\u003e\n\u003ctd style=\"width: 108.375px; height: 19px;\" data-mce-style=\"width: 108.375px; height: 19px;\"\u003e10 mL × 1 vial 2\u003c\/td\u003e\n\u003ctd style=\"width: 118.45px; height: 19px;\" data-mce-style=\"width: 118.45px; height: 19px;\"\u003e2-8℃, 12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNote: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eParameter:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-assay Precision\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThree human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 48px;\" data-mce-style=\"width: 100%; height: 48px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 28.5584%; height: 19px;\" data-mce-style=\"width: 28.5584%; height: 19px;\"\u003e\u003cstrong\u003eParameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.7611%; height: 19px;\" data-mce-style=\"width: 21.7611%; height: 19px;\"\u003e\u003cstrong\u003eSample 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.7683%; height: 19px;\" data-mce-style=\"width: 23.7683%; height: 19px;\"\u003e\u003cstrong\u003eSample 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8175%; height: 19px;\" data-mce-style=\"width: 24.8175%; height: 19px;\"\u003e\u003cstrong\u003eSample 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 28.5584%; height: 19px;\" data-mce-style=\"width: 28.5584%; height: 19px;\"\u003e\u003cstrong\u003eMean (mmol\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.7611%; height: 19px;\" data-mce-style=\"width: 21.7611%; height: 19px;\"\u003e0.05\u003c\/td\u003e\n\u003ctd style=\"width: 23.7683%; height: 19px;\" data-mce-style=\"width: 23.7683%; height: 19px;\"\u003e1.20\u003c\/td\u003e\n\u003ctd style=\"width: 24.8175%; height: 19px;\" data-mce-style=\"width: 24.8175%; height: 19px;\"\u003e3.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\" data-mce-style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 28.5584%; height: 10px;\" data-mce-style=\"width: 28.5584%; height: 10px;\"\u003e\u003cstrong\u003e%CV \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.7611%; height: 10px;\" data-mce-style=\"width: 21.7611%; height: 10px;\"\u003e2.5\u003c\/td\u003e\n\u003ctd style=\"width: 23.7683%; height: 10px;\" data-mce-style=\"width: 23.7683%; height: 10px;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"width: 24.8175%; height: 10px;\" data-mce-style=\"width: 24.8175%; height: 10px;\"\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInter-assay Precision\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThree human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 53px;\" width=\"100%\" data-mce-style=\"width: 100%; height: 53px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 28.5584%; height: 19px;\" data-mce-style=\"width: 28.5584%; height: 19px;\"\u003e\u003cstrong\u003eParameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.7611%; height: 19px;\" data-mce-style=\"width: 21.7611%; height: 19px;\"\u003e\u003cstrong\u003eSample 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.7683%; height: 19px;\" data-mce-style=\"width: 23.7683%; height: 19px;\"\u003e\u003cstrong\u003eSample 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8175%; height: 19px;\" data-mce-style=\"width: 24.8175%; height: 19px;\"\u003e\u003cstrong\u003eSample 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15px;\" data-mce-style=\"height: 15px;\"\u003e\n\u003ctd style=\"width: 28.5584%; height: 15px;\" data-mce-style=\"width: 28.5584%; height: 15px;\"\u003e\u003cstrong\u003eMean (mmol\/L) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.7611%; height: 15px;\" data-mce-style=\"width: 21.7611%; height: 15px;\"\u003e0.05\u003c\/td\u003e\n\u003ctd style=\"width: 23.7683%; height: 15px;\" data-mce-style=\"width: 23.7683%; height: 15px;\"\u003e1.20\u003c\/td\u003e\n\u003ctd style=\"width: 24.8175%; height: 15px;\" data-mce-style=\"width: 24.8175%; height: 15px;\"\u003e3.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 28.5584%; height: 19px;\" data-mce-style=\"width: 28.5584%; height: 19px;\"\u003e\u003cstrong\u003e%CV \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.7611%; height: 19px;\" data-mce-style=\"width: 21.7611%; height: 19px;\"\u003e4.3\u003c\/td\u003e\n\u003ctd style=\"width: 23.7683%; height: 19px;\" data-mce-style=\"width: 23.7683%; height: 19px;\"\u003e4.8\u003c\/td\u003e\n\u003ctd style=\"width: 24.8175%; height: 19px;\" data-mce-style=\"width: 24.8175%; height: 19px;\"\u003e4.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecovery\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTake three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 103%.\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 73px;\" data-mce-style=\"width: 100%; height: 73px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 32.573%; height: 20px;\" data-mce-style=\"width: 32.573%; height: 20px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.0311%; height: 20px;\" data-mce-style=\"width: 21.0311%; height: 20px;\"\u003e\u003cstrong\u003eSample 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.6662%; height: 20px;\" data-mce-style=\"width: 20.6662%; height: 20px;\"\u003e\u003cstrong\u003eSample 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.635%; height: 20px;\" data-mce-style=\"width: 24.635%; height: 20px;\"\u003e\u003cstrong\u003eSample 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15px;\" data-mce-style=\"height: 15px;\"\u003e\n\u003ctd style=\"width: 32.573%; height: 15px;\" data-mce-style=\"width: 32.573%; height: 15px;\"\u003e\u003cstrong\u003eExpected Conc. (mmol\/L) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.0311%; height: 15px;\" data-mce-style=\"width: 21.0311%; height: 15px;\"\u003e0.1\u003c\/td\u003e\n\u003ctd style=\"width: 20.6662%; height: 15px;\" data-mce-style=\"width: 20.6662%; height: 15px;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 24.635%; height: 15px;\" data-mce-style=\"width: 24.635%; height: 15px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 32.573%; height: 19px;\" data-mce-style=\"width: 32.573%; height: 19px;\"\u003e\u003cstrong\u003eObserved Conc. (mmol\/L) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.0311%; height: 19px;\" data-mce-style=\"width: 21.0311%; height: 19px;\"\u003e0.1\u003c\/td\u003e\n\u003ctd style=\"width: 20.6662%; height: 19px;\" data-mce-style=\"width: 20.6662%; height: 19px;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 24.635%; height: 19px;\" data-mce-style=\"width: 24.635%; height: 19px;\"\u003e3.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 32.573%; height: 19px;\" data-mce-style=\"width: 32.573%; height: 19px;\"\u003e\u003cstrong\u003eRecovery rate (%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21.0311%; height: 19px;\" data-mce-style=\"width: 21.0311%; height: 19px;\"\u003e104\u003c\/td\u003e\n\u003ctd style=\"width: 20.6662%; height: 19px;\" data-mce-style=\"width: 20.6662%; height: 19px;\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"width: 24.635%; height: 19px;\" data-mce-style=\"width: 24.635%; height: 19px;\"\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe analytical sensitivity of the assay is 0.007 mmol\/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.\u003c\/p\u003e","brand":"Elabscience Biotechnology","offers":[{"title":"100 Assays","offer_id":40362294607930,"sku":"E-BC-K018-S-100","price":224.95,"currency_code":"USD","in_stock":true},{"title":"50 Assays","offer_id":40362294640698,"sku":"E-BC-K018-S-50","price":168.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/E-BC-K018-S.jpg?v=1712581336","url":"https:\/\/www.msesupplies.com\/en-gb\/products\/d-xylose-colorimetric-assay-kit","provider":"MSE Supplies","version":"1.0","type":"link"}