{"title":"Magnetic Properties","description":"","products":[{"product_id":"seebeck-coefficient-and-resistivity-testing-analytical-service","title":"Seebeck Coefficient and Resistivity Testing Analytical Service","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eSeebeck Coefficient and Resistivity Testing measures the thermoelectric properties of materials, including their ability to convert temperature differences into electrical voltage (Seebeck coefficient) and their electrical resistivity. These properties are crucial for evaluating materials for thermoelectric applications such as energy harvesting, cooling, and temperature sensing. The system typically applies a temperature gradient to the material and measures the resulting voltage and resistance, providing insights into the material's efficiency and performance.\u003c\/p\u003e\n\u003ch3\u003eSample Requirements\u003c\/h3\u003e\n\u003cp\u003eBulk sample: Length 10–12 mm (preferably 11 mm), width 2–4 mm, height 2–3 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003eNote: The listed price is for reference only. Please request a quote for the final pricing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cb\u003e\u003cspan class=\"x_1001630995colour\"\u003eAnalytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003ePlease contact sales@msesupplies.com for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003e***Please do not ship any samples without authorization from MSE Supplies***\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"cost per temperature point, -120 °C-room temperature","offer_id":40736135020602,"sku":"SEEBECK001","price":471.95,"currency_code":"USD","in_stock":true},{"title":"cost per temperature point, room temperature-400 °C","offer_id":40736135053370,"sku":"SEEBECK002","price":197.95,"currency_code":"USD","in_stock":true},{"title":"cost per temperature point, 400-1150℃","offer_id":40736135086138,"sku":"SEEBECK003","price":393.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/seebeck-coefficient-and-resistivity-testing-analytical-service-cost-per-temperature-point-120-c-room-temperature-mse-supplies-llc-analytical-services-22499942531130.png?v=1752496201"},{"product_id":"vibrating-sample-magnetometer-vsm-analytical-service","title":"Vibrating Sample Magnetometer (VSM) Analytical Service","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eVSM is a Vibrating Sample Magnetometer (abbreviated as VSM). Its primary function is to measure the magnetic properties of materials, determine the type of magnetic material, and obtain parameters such as coercivity, remanence, and saturation magnetization. It is commonly used for various ferromagnetic, ferrimagnetic, antiferromagnetic, paramagnetic, and diamagnetic materials.\u003c\/p\u003e\n\u003cp\u003eVSM is generally applied in the following fields:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRare-Earth Permanent Magnetic Material Research:\u003c\/strong\u003e\u003cbr\u003eVSM can be used to measure the magnetic properties of rare-earth permanent magnetic materials, such as magnetization, coercivity, and magnetic energy product.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFerrite Material Research:\u003c\/strong\u003e\u003cbr\u003eVSM can measure the magnetic properties of ferrite materials, including magnetization, hysteresis loops, and demagnetization curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmorphous and Quasicrystalline Material Research:\u003c\/strong\u003e\u003cbr\u003eVSM can be used to measure the magnetic properties of amorphous and quasicrystalline materials, such as magnetization, hysteresis loops, and demagnetization curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperconducting Material Research:\u003c\/strong\u003e\u003cbr\u003eVSM can measure the magnetic properties of superconducting materials, such as magnetization, hysteresis loops, and demagnetization curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Research of Alloys, Compounds, and Biological Proteins:\u003c\/strong\u003e\u003cbr\u003eVSM can measure the intrinsic magnetic properties of various substances, such as magnetization, Curie temperature, and coercivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement of Magnetic Powders, Particles, Sheets, and Bulk Materials:\u003c\/strong\u003e\u003cbr\u003eVSM can be used to measure the magnetic properties of magnetic materials in different forms, including magnetization, hysteresis loops, and demagnetization curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSample Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowder samples should be at least \u003cstrong data-end=\"43\" data-start=\"34\"\u003e10 mg\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eBulk samples should be between \u003cstrong data-end=\"113\" data-start=\"76\"\u003e1×1×1 mm³ and less than 3×3×3 mm³\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003eLiquid samples are more difficult to measure, so please provide at least \u003cstrong data-end=\"197\" data-start=\"188\"\u003e50 μL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTesting Conditions for Standard Hysteresis Loops:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMagnetite (Fe₃O₄), ferrites, Fe, Co, and their composites are suitable for 2T (2 Tesla) testing.\u003c\/li\u003e\n\u003cli\u003eRoom temperature.\u003c\/li\u003e\n\u003cli\u003eMagnetic field within ±2 T.\u003c\/li\u003e\n\u003cli\u003eDefault data points: 120–150.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eNote: The listed price is for reference only. Please request a quote for the final pricing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cb\u003e\u003cspan class=\"x_1001630995colour\"\u003eAnalytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\"\u003e\u003cstrong\u003ePlease contact sales@msesupplies.com for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\"\u003e\u003cstrong\u003e***Please do not ship any samples without authorization from MSE Supplies***\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"Liquid samples","offer_id":40828723953722,"sku":"VSM002","price":169.95,"currency_code":"USD","in_stock":true},{"title":"Solid samples","offer_id":40828723986490,"sku":"VSM001","price":142.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Screenshot2024-12-09114558_9d963394-669e-445c-9989-dfd4e63bc861.png?v=1735825243"},{"product_id":"physical-property-measurement-system-ppms-analytical-service","title":"Physical Property Measurement System (PPMS) Analytical Service","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe design concept of the Physical Property Measurement System (PPMS) is to integrate fully automated measurement capabilities for electrical, magnetic, and thermal properties on a platform with precisely controlled temperature and strong magnetic fields. The basic functionalities of the PPMS can be divided into the following components: temperature and magnetic field control, DC electrical measurements, and the PPMS control software system. The core hardware of the basic system includes the measurement sample chamber, standard liquid helium Dewar, superconducting magnet with power supply, vacuum pump, computer, and electronic control systems.\u003c\/p\u003e\n\u003cp\u003eFor most routine experimental projects, the PPMS is equipped with pre-designed automated measurement software and standard measurement capabilities such as hysteresis loops, resistivity, magnetoresistance, Hall coefficient, and current-voltage characteristics. Additionally, the MPMS-SQUID system is available for detecting weak magnetic signals with higher precision testing capabilities.\u003c\/p\u003e\n\u003ch3\u003eSample Requirements:\u003c\/h3\u003e\n\u003cp\u003ePowder Samples: \u0026gt;3 mg, ideally within the range of 10–50 mg.\u003c\/p\u003e\n\u003cp\u003eBulk Samples: 0.1 × 0.1 × 0.1 mm \u0026lt; bulk sample \u0026lt; 2 × 2 × 2 mm.\u003c\/p\u003e\n\u003cp\u003eThin Film Samples: 1 × 1 × 0.1 mm \u0026lt; thin film sample \u0026lt; 2 × 2 × 2 mm.\u003c\/p\u003e\n\u003cp\u003eLiquid Samples: Recommended volume: 1–3 mL, with a minimum of 50 µL.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003eNote: The listed price is for reference only. Please request a quote for the final pricing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cb\u003e\u003cspan class=\"x_1001630995colour\"\u003eAnalytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003ePlease contact sales@msesupplies.com for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003e***Please do not ship any samples without authorization from MSE Supplies***\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"M-H Curve","offer_id":40736220217402,"sku":"PPMS001","price":329.95,"currency_code":"USD","in_stock":true},{"title":"M-T Curve","offer_id":40736220250170,"sku":"PPMS002","price":274.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/2021101513401773599592877_2e87b5dc-2a2a-4cdd-8116-76c67b438ce2.png?v=1735820424"},{"product_id":"microwave-vector-network-analyzer-vector-network-vna-analytical-service","title":"Microwave Vector Network Analyzer \/ Vector Network (VNA) Analytical Service","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eA Microwave Vector Network Analyzer (VNA) is a precision instrument used to measure the transmission and reflection properties of RF and microwave devices across a wide frequency range. It analyzes S-parameters (e.g., S11, S21) to provide detailed amplitude and phase information, enabling accurate characterization of components like antennas, filters, amplifiers, and cables. VNAs are essential in industries such as telecommunications, aerospace, and electronics for tasks like impedance matching, device performance evaluation, and signal integrity analysis, making them indispensable tools in RF and microwave engineering.\u003c\/p\u003e\n\u003cp\u003eA vector network analyzer can test electromagnetic shielding and absorption performance. Electromagnetic shielding is primarily calculated using S-parameters, while absorption efficiency is calculated using electromagnetic parameters.\u003c\/p\u003e\n\u003ch3\u003eSample Requirements\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePowder Sample Testing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCoaxial method: Requires at least 200 mg of powder sample (paraffin is not needed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBulk Sample Testing (Coaxial Method):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequires a coaxial ring with dimensions of outer diameter 7 mm, inner diameter 3.04 mm, and thickness 2 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBulk Sample Testing (Waveguide Method):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDifferent frequency ranges require corresponding sample dimensions:\n\u003cul\u003e\n\u003cli\u003e1.13–1.73 GHz: 82.4 × 164.8 × (10.0–35.0) mm\u003c\/li\u003e\n\u003cli\u003e1.72–2.61 GHz: 54.46 × 108.92 × (8.0–12.0) mm\u003c\/li\u003e\n\u003cli\u003e2.60–3.95 GHz: 33.89 × 71.84 × (8.0–12.0) mm\u003c\/li\u003e\n\u003cli\u003e3.94–5.99 GHz: 22.0 × 47.25 × (8.0–12.0) mm\u003c\/li\u003e\n\u003cli\u003e5.38–8.17 GHz: 15.75 × 34.70 × (2.0–6.0) mm\u003c\/li\u003e\n\u003cli\u003e8.2–12.4 GHz: 22.9 × 10.2 × (2.0–6.0) mm\u003c\/li\u003e\n\u003cli\u003e12.4–18.0 GHz: 15.9 × 8.03 × (2.0–4.0) mm\u003c\/li\u003e\n\u003cli\u003e18.0–26.5 GHz: 10.95 × 4.5 × (2.0–4.0) mm\u003c\/li\u003e\n\u003cli\u003e26.0–40.0 GHz: 7.15 × 3.60 × (2.0–4.0) mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBulk Sample Testing (Arch Method):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequires samples with one of the following dimensions: 180 × 180 mm, 300 × 300 mm, or 600 × 600 mm. This method directly measures absorption efficiency but cannot measure electromagnetic parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSPDR Testing for Bulk Samples:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSamples must have uniform thickness and a dielectric constant \u0026gt; 20. Dimensions required (length\/width or diameter, thickness):\n\u003cul\u003e\n\u003cli\u003e1 GHz: 110–190 mm, 3 mm\u003c\/li\u003e\n\u003cli\u003e2.5 GHz: 60–120 mm, 3 mm\u003c\/li\u003e\n\u003cli\u003e3 GHz: 50–120 mm, 3 mm\u003c\/li\u003e\n\u003cli\u003e5 GHz: 50–100 mm, 1.6 mm\u003c\/li\u003e\n\u003cli\u003e10 GHz: 30–100 mm, 1 mm\u003c\/li\u003e\n\u003cli\u003e15 GHz: 20–100 mm, 0.5 mm\u003c\/li\u003e\n\u003cli\u003e20 GHz: 20–40 mm, 0.5 mm\u003c\/li\u003e\n\u003cli\u003e28 GHz: 20–40 mm, 0.5 mm\u003c\/li\u003e\n\u003cli\u003e39 GHz: 20–40 mm, 0.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuasi-Optical Cavity Testing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSamples must have uniform thickness and a dielectric constant \u0026lt; 20, with dimensions: length \u0026gt; 40 mm, width \u0026gt; 40 mm, and thickness \u0026lt; 1 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003eNote: The listed price is for reference only. Please request a quote for the final pricing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cb\u003e\u003cspan class=\"x_1001630995colour\"\u003eAnalytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003ePlease contact sales@msesupplies.com for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003e***Please do not ship any samples without authorization from MSE Supplies***\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"Default Title","offer_id":40736238796858,"sku":"VNA001","price":329.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/microwave-vector-network-analyzer-vector-network-vna-analytical-service-default-title-mse-supplies-llc-analytical-services-22555921514554.png?v=1752496170"},{"product_id":"magnetostrictive-coefficient-measurement-analytical-service","title":"Magnetostrictive Coefficient Measurement Analytical Service","description":"\u003cp\u003eThe measurement of the magnetostrictive coefficient involves quantifying the extent to which a material changes its shape or dimensions when subjected to a magnetic field. Magnetostrictive materials, such as certain metals and alloys, exhibit this property due to the reorientation of magnetic domains within the material. This phenomenon is essential in various applications, including sensors, actuators, and transducers, as it allows for the conversion of magnetic energy into mechanical motion and vice versa. Measurement techniques typically include strain gauge methods, laser interferometry, or capacitance-based displacement measurement for accurate determination。\u003c\/p\u003e\n\u003ch3\u003eSample Requirement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSample Condition\u003c\/strong\u003e: Currently, only bulk samples are measured; flexible thin films are not tested (rigid thin sheets can be tested).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptimal Size Requirements\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor tests without applied pressure, the surface in the direction of sample expansion should be as large as possible, with at least one edge \u0026gt;10 mm and the other edge \u0026gt;6 mm.\u003c\/li\u003e\n\u003cli\u003eFor tests with applied pressure, the sample must be cylindrical. The diameter or side length should be 10–45 mm, and the height should be 40–55 mm. The parallelism of the two end faces should be as high as possible, with a deviation of less than 0.05 (the flatter, the better). It is recommended to polish the testing surface with sandpaper beforehand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003eNote: The listed price is for reference only. Please request a quote for the final pricing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cb\u003e\u003cspan class=\"x_1001630995colour\"\u003eAnalytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250.\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003ePlease contact sales@msesupplies.com for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #00aaff;\" data-mce-style=\"color: #00aaff;\"\u003e\u003cstrong\u003e***Please do not ship any samples without authorization from MSE Supplies***\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"Default Title","offer_id":40736289849402,"sku":"MGCM001","price":197.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/2024020213473298276644708.png?v=1735723303"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/collections\/Magnetic_Properties.jpg?v=1769048833","url":"https:\/\/www.msesupplies.com\/en-gb\/collections\/magnetic-properties.oembed","provider":"MSE Supplies","version":"1.0","type":"link"}