{"title":"Hypoxia Incubators","description":"","products":[{"product_id":"maworde-hypoxia-incubator-without-temperature-control-ideal-for-small-scale-cell-culture-experiment","title":"MAWORDE Hypoxia Incubator Without Temperature Control, Ideal for Small-Scale Cell Culture Experiment","description":"\u003ch2\u003eMAWORDE Hypoxia Incubator Without Temperature Control, Ideal for Small-Scale Cell Culture Experiment\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GC-C is a hypoxia cell incubator that provides precise control of O₂ and CO₂ levels, rapidly reaching the set conditions. It can be integrated into a temperature-controlled incubator and is ideal for small-scale continuous cell culture and passaging, simulating the physiological environment of cells in vivo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\" data-id=\"9826b31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"6c62cae\" class=\"elementor-element elementor-element-6c62cae elementor-widget elementor-widget-text-editor\"\u003e\n\u003ch3\u003eKey Specification:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"b79d7db\" class=\"elementor-element elementor-element-b79d7db elementor-widget elementor-widget-text-editor\"\u003e\n\u003cp\u003eOur workstation ensures precise, reliable culture conditions with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control (Option)\u003c\/strong\u003e: Room humidity to 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control (Option)\u003c\/strong\u003e: 3°C above ambient up to 45°C, in 0.1°C increments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003ePrecise O\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; CO\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003eControl\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-7706630 elementor-widget elementor-widget-text-editor\" data-id=\"7706630\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul data-start=\"94\" data-end=\"459\"\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"144\" data-end=\"165\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"217\" data-end=\"239\" data-is-only-node=\"\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments (upgradeable to 0–60.0%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cstrong data-start=\"442\" data-end=\"473\"\u003eOptional Built-in Air Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for an external compressed air source (O₂ control range: 0.1%–18%)\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"568\" data-end=\"598\"\u003eOptional Anaerobic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables integrated hypoxia\/anaerobic dual-mode operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C.jpg?v=1770746554\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"bc488ff\" class=\"elementor-element elementor-element-bc488ff elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eRapid Gas Stabilization\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"b3e64b5\" class=\"elementor-element elementor-element-b3e64b5 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"217\" data-start=\"38\"\u003e\n\u003cp data-end=\"217\" data-start=\"40\"\u003eQuickly reaches the set conditions and maintains stable, precise control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"217\" data-start=\"38\"\u003e\n\u003cp data-end=\"217\" data-start=\"40\"\u003eGas environment rapidly restores to the preset state after door opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-A.jpg?v=1770746626\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"f6f81d1\" class=\"elementor-element elementor-element-f6f81d1 elementor-widget elementor-widget-heading\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-b09267e elementor-widget elementor-widget-heading\" data-id=\"b09267e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMulti-Stage Hypoxia Cycle\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-6e91cf4 elementor-widget elementor-widget-text-editor\" data-id=\"6e91cf4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eSupports 4, 10, or more automated gas cycling stages to suit different experimental needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eUsers can set cycle duration, gas concentrations, and the number of cycles according to their experiment requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-B.jpg?v=1770746695\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"d76275d\" class=\"elementor-element elementor-element-d76275d elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"e4a324d\" class=\"elementor-element elementor-element-e4a324d elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"e2d8c4f\" class=\"elementor-element elementor-element-e2d8c4f elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"10fdcf5\" class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"259b338\" class=\"elementor-element elementor-element-259b338 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eData Visualization \u0026amp; Recording\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"7bbc8d1\" class=\"elementor-element elementor-element-7bbc8d1 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"126\" data-start=\"36\"\u003e\n\u003cp data-end=\"126\" data-start=\"38\"\u003eReal-time monitoring and synchronized logging of O₂ and CO₂ levels inside the chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"213\" data-start=\"127\"\u003e\n\u003cp data-end=\"213\" data-start=\"129\"\u003eAutomatic generation of 24-hour environmental trend charts for parameter analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"254\" data-start=\"214\"\u003e\n\u003cp data-end=\"254\" data-start=\"216\"\u003eUSB-based data export in CSV format\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"354\" data-start=\"255\"\u003e\n\u003cp data-end=\"354\" data-start=\"257\"\u003eContinuous recording and storage of historical data to ensure complete experimental traceability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-C.jpg?v=1770746767\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eGC-C Series Specification\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-D.jpg?v=1770746859\" alt=\"\"\u003e\u003c\/p\u003e\nOptions:\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"10fdcf5\" class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"f88d3a8\" class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Monitoring\u003c\/strong\u003e: Room humidity to 90%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control\u003c\/strong\u003e: Room humidity to 80%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder Low-Pressure System\u003c\/strong\u003e: Real-time gas pressure monitoring and alerts for cylinder low pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Port:\u003c\/strong\u003e Facilitates equipment integration within the workstation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Oxygen System:\u003c\/strong\u003e Maintains elevated oxygen levels for specific research requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnaerobic System:\u003c\/strong\u003e Combines hypoxia and anaerobic conditions in a single workstation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"f88d3a8\" class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\n\u003cdiv class=\"elementor-element elementor-element-a432df3 elementor-widget elementor-widget-text-editor\" data-id=\"a432df3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eOptional Feature\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-E.jpg?v=1770746999\"\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Dimensions:\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-F.jpg?v=1770747194\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C_T__Hypoxia_Incubator_User_manual.pdf?v=1770826880\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MAWORDE","offers":[{"title":"140 (H)*320 (W)*280 (D) \/ Clear\/Black","offer_id":41231908929594,"sku":"MAWORDE-GC-C01","price":11546.95,"currency_code":"USD","in_stock":true},{"title":"210 (H)*320 (W)*280 (D) \/ Clear\/Black","offer_id":41231908962362,"sku":"MAWORDE-GC-C02","price":12699.95,"currency_code":"USD","in_stock":true},{"title":"270 (H)*350 (W)*290 (D) \/ Clear\/Black","offer_id":41231908995130,"sku":"MAWORDE-GC-C03","price":13758.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-G_3256b0e8-768c-4756-8110-1f6d0628e643.jpg?v=1770747489"},{"product_id":"maworde-hypoxia-incubator-with-temperature-control-ideal-for-small-scale-cell-culture-experiment","title":"MAWORDE Hypoxia Incubator With Temperature Control, Ideal for Small-Scale Cell Culture Experiment","description":"\u003ch2\u003eMAWORDE Hypoxia Incubator with Temperature Control, Ideal for Small-Scale Cell Culture Experiment\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GC-CT is a hypoxia cell incubator that provides precise control of O₂ and CO₂ levels and rapidly reaches the set conditions. With an integrated temperature control module, it supports standalone operation for direct incubation. It is well suited for small-scale continuous cell culture and passaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\" data-id=\"9826b31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"9826b31\" class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-6c62cae elementor-widget elementor-widget-text-editor\" data-id=\"6c62cae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003ch3\u003eKey Specification:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-b79d7db elementor-widget elementor-widget-text-editor\" data-id=\"b79d7db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cp\u003eOur workstation ensures precise, reliable culture conditions with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"144\" data-end=\"165\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"217\" data-end=\"239\" data-is-only-node=\"\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control (Option)\u003c\/strong\u003e: Room humidity to 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control (Option)\u003c\/strong\u003e: 3°C above ambient up to 45°C, in 0.1°C increments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003ePrecise O\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; CO\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003eControl\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"7706630\" class=\"elementor-element elementor-element-7706630 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul data-end=\"459\" data-start=\"94\"\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments (upgradeable to 0–60.0%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cstrong data-end=\"473\" data-start=\"442\"\u003eOptional Built-in Air Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for an external compressed air source (O₂ control range: 0.1%–18%)\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"598\" data-start=\"568\"\u003eOptional Anaerobic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables integrated hypoxia\/anaerobic dual-mode operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C.jpg?v=1770746554\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-bc488ff elementor-widget elementor-widget-heading\" data-id=\"bc488ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eRapid Gas Stabilization\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-b3e64b5 elementor-widget elementor-widget-text-editor\" data-id=\"b3e64b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"38\" data-end=\"217\"\u003e\n\u003cp data-start=\"40\" data-end=\"217\"\u003eQuickly reaches the set conditions and maintains stable, precise control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"38\" data-end=\"217\"\u003e\n\u003cp data-start=\"40\" data-end=\"217\"\u003eGas environment rapidly restores to the preset state after door opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-A.jpg?v=1770746626\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-f6f81d1 elementor-widget elementor-widget-heading\" data-id=\"f6f81d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"b09267e\" class=\"elementor-element elementor-element-b09267e elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMulti-Stage Hypoxia Cycle\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"6e91cf4\" class=\"elementor-element elementor-element-6e91cf4 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"691\" data-start=\"611\"\u003e\n\u003cp data-end=\"691\" data-start=\"613\"\u003eSupports 4, 10, or more automated gas cycling stages to suit different experimental needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"758\" data-start=\"692\"\u003e\n\u003cp data-end=\"758\" data-start=\"694\"\u003eUsers can set cycle duration, gas concentrations, and the number of cycles according to their experiment requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-B.jpg?v=1770746695\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-d76275d elementor-widget elementor-widget-text-editor\" data-id=\"d76275d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-e4a324d elementor-widget elementor-widget-text-editor\" data-id=\"e4a324d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-e2d8c4f elementor-widget elementor-widget-text-editor\" data-id=\"e2d8c4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-259b338 elementor-widget elementor-widget-heading\" data-id=\"259b338\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eData Visualization \u0026amp; Recording\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-7bbc8d1 elementor-widget elementor-widget-text-editor\" data-id=\"7bbc8d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"36\" data-end=\"126\"\u003e\n\u003cp data-start=\"38\" data-end=\"126\"\u003eReal-time monitoring and synchronized logging of O₂ and CO₂ levels inside the chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"127\" data-end=\"213\"\u003e\n\u003cp data-start=\"129\" data-end=\"213\"\u003eAutomatic generation of 24-hour environmental trend charts for parameter analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"214\" data-end=\"254\"\u003e\n\u003cp data-start=\"216\" data-end=\"254\"\u003eUSB-based data export in CSV format\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"255\" data-end=\"354\"\u003e\n\u003cp data-start=\"257\" data-end=\"354\"\u003eContinuous recording and storage of historical data to ensure complete experimental traceability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-C.jpg?v=1770746767\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eGC-C Series Specification\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-D.jpg?v=1770746859\"\u003e\u003c\/p\u003e\nOptions:\n\u003cdiv class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\" data-id=\"10fdcf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\" data-id=\"f88d3a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"a432df3\" class=\"elementor-element elementor-element-a432df3 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Monitoring\u003c\/strong\u003e: Room humidity to 90%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control\u003c\/strong\u003e: Room humidity to 80%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder Low-Pressure System\u003c\/strong\u003e: Real-time gas pressure monitoring and alerts for cylinder low pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Port:\u003c\/strong\u003e Facilitates equipment integration within the workstation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Oxygen System:\u003c\/strong\u003e Maintains elevated oxygen levels for specific research requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnaerobic System:\u003c\/strong\u003e Combines hypoxia and anaerobic conditions in a single workstation\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eOptional Feature\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-E.jpg?v=1770746999\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Dimensions:\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C-F.jpg?v=1770747194\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-C_T__Hypoxia_Incubator_User_manual.pdf?v=1770826880\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MAWORDE","offers":[{"title":"270 (H)*350 (W)*290 (D)","offer_id":41231909027898,"sku":"MAWORDE-GC-CT","price":15524.95,"currency_code":"USD","in_stock":true},{"title":"270 (H)*350 (W)*390 (D)","offer_id":41231909060666,"sku":"MAWORDE-GC-CTL","price":17090.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GC-CT.jpg?v=1770748194"}],"url":"https:\/\/www.msesupplies.com\/en-gb\/collections\/hypoxia-incubators.oembed","provider":"MSE Supplies","version":"1.0","type":"link"}