{"product_id":"neware-wgdw-400l2-70c-380v-12u-b-70-to-150-all-in-one-400l-battery-testing-system","title":"Neware WGDW-400L2-70C-380V-12U-B, -70 to 150℃ All-in-One 400L battery Testing System","description":"\u003ch2 data-end=\"87\" data-start=\"0\" data-section-id=\"12vu5y0\"\u003eNeware WGDW-400L2-70C-380V-12U-B, -70 to 150℃ All-in-One 400L Battery Testing System\u003c\/h2\u003e\n\u003ch3 data-end=\"105\" data-start=\"89\" data-section-id=\"zamd46\"\u003eIntroduction\u003c\/h3\u003e\n\u003cp data-end=\"698\" data-start=\"107\"\u003eThe \u003cstrong data-end=\"199\" data-start=\"111\"\u003eNeware WGDW-400L2-70C-380V-12U-B, -70 to 150℃ All-in-One 400L Battery Testing System\u003c\/strong\u003e is an automatic fire-extinguishing dual-temperature-zone chamber designed for cell performance testing under controlled high- and low-temperature conditions. It combines a 225L × 2 dual-zone chamber with integrated 5V30A64CH (Series 4) testing equipment, making it suitable for new energy production enterprises and research institutes that require reliable environmental and performance testing for battery cells.\u003c\/p\u003e\n\u003cp data-end=\"1243\" data-start=\"700\"\u003eWith a temperature range of -70℃ to 150℃, programmable chamber control, smoke detection, exhaust, fire extinguishing, and insulated multi-layer cell trays, this all-in-one system supports efficient thermal testing and integrated battery test operation. The fire-extinguishing version also adds a safety relief port, safety guard chain, smoke detection, smoke exhaust, and fire extinguishing functions for enhanced protection.\u003c\/p\u003e\n\u003ch3 data-end=\"1261\" data-start=\"1245\" data-section-id=\"1iz91iu\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-end=\"2143\" data-start=\"1263\"\u003e\n\u003cli data-end=\"1315\" data-start=\"1263\" data-section-id=\"qm3fh9\"\u003eAll-in-one dual-zone battery cell testing system\u003c\/li\u003e\n\u003cli data-end=\"1364\" data-start=\"1316\" data-section-id=\"176csof\"\u003eProduct model: WGDW-400L2-70C-380V-12U-B\u003c\/li\u003e\n\u003cli data-end=\"1404\" data-start=\"1365\" data-section-id=\"3guc10\"\u003eTemperature range: -70℃ to 150℃\u003c\/li\u003e\n\u003cli data-end=\"1464\" data-start=\"1405\" data-section-id=\"hnaq23\"\u003eDual temperature zones, nominal volume 225L × 2\u003c\/li\u003e\n\u003cli data-end=\"1522\" data-start=\"1465\" data-section-id=\"zm99ut\"\u003eIntegrated 5V30A64CH (Series 4) testing equipment\u003c\/li\u003e\n\u003cli data-end=\"1595\" data-start=\"1523\" data-section-id=\"12l9766\"\u003eAutomatic fire extinguishing design with smoke detection and exhaust\u003c\/li\u003e\n\u003cli data-end=\"1638\" data-start=\"1596\" data-section-id=\"1sf2eat\"\u003eHigh color LCD touch screen controller\u003c\/li\u003e\n\u003cli data-end=\"1684\" data-start=\"1639\" data-section-id=\"1okuyrv\"\u003eProgram mode and set value mode operation\u003c\/li\u003e\n\u003cli data-end=\"1745\" data-start=\"1685\" data-section-id=\"1xlgim6\"\u003ePT100 temperature sensor with 0.01℃ display accuracy\u003c\/li\u003e\n\u003cli data-end=\"1789\" data-start=\"1746\" data-section-id=\"157ayi\"\u003eHeating time: +20℃ to +150℃ ≤60 min\u003c\/li\u003e\n\u003cli data-end=\"1832\" data-start=\"1790\" data-section-id=\"jxq07w\"\u003eCooling time: +20℃ to -70℃ ≤75 min\u003c\/li\u003e\n\u003cli data-end=\"1900\" data-start=\"1833\" data-section-id=\"1ovrncg\"\u003eAnti-fog observation window, lighting, and insulated cell trays\u003c\/li\u003e\n\u003cli data-end=\"1975\" data-start=\"1901\" data-section-id=\"9gx4qd\"\u003eSupports upper computer programming control and Ethernet communication\u003c\/li\u003e\n\u003cli data-end=\"2143\" data-start=\"1976\" data-section-id=\"5zzp7e\"\u003eSuitable for cylindrical cell performance testing in research and production environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2163\" data-start=\"2145\" data-section-id=\"1yl5694\"\u003eSpecifications\u003c\/h3\u003e\n\u003ch4 data-end=\"2179\" data-start=\"2165\"\u003eDatasheet\u003c\/h4\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"7028\" data-start=\"2181\"\u003e\n\u003cthead data-end=\"2210\" data-start=\"2181\"\u003e\n\u003ctr data-end=\"2210\" data-start=\"2181\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"2193\" data-start=\"2181\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"lg\" data-end=\"2210\" data-start=\"2193\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"7028\" data-start=\"2221\"\u003e\n\u003ctr data-end=\"2371\" data-start=\"2326\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2342\" data-start=\"2326\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2371\" data-start=\"2342\"\u003eWGDW-400L2-70C-380V-12U-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2475\" data-start=\"2372\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2387\" data-start=\"2372\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2475\" data-start=\"2387\"\u003eAutomatic Fire Extinguishing Dual-Temperature Zones High and Low Temperature Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2637\" data-start=\"2476\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2490\" data-start=\"2476\"\u003eInstruction\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2637\" data-start=\"2490\"\u003eAutomatic fire extinguishing type adds safety relief port, safety guard chain, smoke detection, smoke exhaust, and fire extinguishing functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2742\" data-start=\"2638\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2652\" data-start=\"2638\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2742\" data-start=\"2652\"\u003eCell performance testing for new energy production enterprises and research institutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2772\" data-start=\"2743\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2760\" data-start=\"2743\"\u003eNominal Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2772\" data-start=\"2760\"\u003e225L × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2841\" data-start=\"2773\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2816\" data-start=\"2773\"\u003eInner Box Size (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2841\" data-start=\"2816\"\u003eW600 × D500 × H750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2892\" data-start=\"2842\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2864\" data-start=\"2842\"\u003eExternal Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2892\" data-start=\"2864\"\u003eW1110 × D1800 × H2050 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2918\" data-start=\"2893\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2902\" data-start=\"2893\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2918\" data-start=\"2902\"\u003eAbout 760 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2955\" data-start=\"2919\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2939\" data-start=\"2919\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"2955\" data-start=\"2939\"\u003e-70℃ to 150℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3022\" data-start=\"2956\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2982\" data-start=\"2956\"\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3022\" data-start=\"2982\"\u003e≤±0.5℃ (no load, temperature stable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3086\" data-start=\"3023\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3047\" data-start=\"3023\"\u003eTemperature Deviation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3086\" data-start=\"3047\"\u003e±2.0℃ (no load, temperature stable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3127\" data-start=\"3087\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3102\" data-start=\"3087\"\u003eHeating Time\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3127\" data-start=\"3102\"\u003e+20℃ to +150℃ ≤60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3167\" data-start=\"3128\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3143\" data-start=\"3128\"\u003eCooling Time\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3167\" data-start=\"3143\"\u003e+20℃ to -70℃ ≤75 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3229\" data-start=\"3168\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3182\" data-start=\"3168\"\u003eTest Method\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3229\" data-start=\"3182\"\u003eGB\/T 5170.2-2017 Temperature test equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3335\" data-start=\"3230\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3246\" data-start=\"3230\"\u003eStandards Met\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3335\" data-start=\"3246\"\u003eGB\/T 2423.1-2008, GB\/T 2423.2-2008, GJB 150.3A-2009, GJB 150.4A-2009, GB\/T 10592-2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3426\" data-start=\"3336\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3361\" data-start=\"3336\"\u003eExterior Wall Material\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3426\" data-start=\"3361\"\u003eHigh quality cold rolled steel plate, surface spray treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3481\" data-start=\"3427\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3449\" data-start=\"3427\"\u003eInner Wall Material\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3481\" data-start=\"3449\"\u003eSUS304 stainless steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3557\" data-start=\"3482\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3504\" data-start=\"3482\"\u003eInsulation Material\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3557\" data-start=\"3504\"\u003eHard polyurethane foam + aluminum silicate cotton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3591\" data-start=\"3558\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3581\" data-start=\"3558\"\u003eInsulation Thickness\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3591\" data-start=\"3581\"\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3717\" data-start=\"3592\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3619\" data-start=\"3592\"\u003eAir Conditioning Channel\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3717\" data-start=\"3619\"\u003eCentrifugal fan, heater, evaporator (also dehumidifier), C-type air supply and return air mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3770\" data-start=\"3718\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3756\" data-start=\"3718\"\u003eLead Hole (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3770\" data-start=\"3756\"\u003eφ50 mm \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3807\" data-start=\"3771\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3780\" data-start=\"3771\"\u003eWheels\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3807\" data-start=\"3780\"\u003e4, with adjustable feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3930\" data-start=\"3808\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3829\" data-start=\"3808\"\u003eObservation Window\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3930\" data-start=\"3829\"\u003eMulti-layer hollow electric heating anti-fog observation window, about 330 × 450 mm visible range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3973\" data-start=\"3931\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3968\" data-start=\"3931\"\u003eLighting (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"3973\" data-start=\"3968\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4077\" data-start=\"3974\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4012\" data-start=\"3974\"\u003eCell Tray (Single Temperature Zone)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4077\" data-start=\"4012\"\u003e2 layers, high-temperature resistant electric insulation tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4133\" data-start=\"4078\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4099\" data-start=\"4078\"\u003eTray Load Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4133\" data-start=\"4099\"\u003e20 kg\/layer evenly distributed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4179\" data-start=\"4134\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4170\" data-start=\"4134\"\u003eMaximum Total Sample Load per Box\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4179\" data-start=\"4170\"\u003e80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4239\" data-start=\"4180\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4192\" data-start=\"4180\"\u003eDoor Type\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4239\" data-start=\"4192\"\u003eSingle hinge door, left hinge, right handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4383\" data-start=\"4240\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4256\" data-start=\"4240\"\u003eDoor Features\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4383\" data-start=\"4256\"\u003eObservation window, lighting lamp, anti-condensation heating, double-layer silicone sealing strip, safety protection chains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4458\" data-start=\"4384\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4400\" data-start=\"4384\"\u003eControl Panel\u003c\/td\u003e\n\u003ctd data-end=\"4458\" data-start=\"4400\" data-col-size=\"lg\"\u003eController display, over-temperature protection setter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4543\" data-start=\"4459\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4488\" data-start=\"4459\"\u003eRefrigeration Working Mode\u003c\/td\u003e\n\u003ctd data-end=\"4543\" data-start=\"4488\" data-col-size=\"lg\"\u003eMechanical compression cascade refrigeration method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4660\" data-start=\"4544\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4571\" data-start=\"4544\"\u003eRefrigeration Compressor\u003c\/td\u003e\n\u003ctd data-end=\"4660\" data-start=\"4571\" data-col-size=\"lg\"\u003eFrance imported “Taikang” fully enclosed compressor or Emerson gas turbine compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4797\" data-start=\"4661\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4693\" data-start=\"4661\"\u003eMain Refrigeration Components\u003c\/td\u003e\n\u003ctd data-end=\"4797\" data-start=\"4693\" data-col-size=\"lg\"\u003eThrottle valve, pressure controller, drying filter, cooling solenoid valve, reservoir, oil separator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4841\" data-start=\"4798\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4811\" data-start=\"4798\"\u003eEvaporator\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4841\" data-start=\"4811\"\u003eFinned tube heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4895\" data-start=\"4842\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4854\" data-start=\"4842\"\u003eCondenser\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4895\" data-start=\"4854\"\u003eAir-cooled finned tube heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4949\" data-start=\"4896\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4914\" data-start=\"4896\"\u003eThrottle Device\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4949\" data-start=\"4914\"\u003eThrottle valve \/ capillary tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4979\" data-start=\"4950\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4964\" data-start=\"4950\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"4979\" data-start=\"4964\"\u003eR404A \/ R23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5027\" data-start=\"4980\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4994\" data-start=\"4980\"\u003eHeater Type\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5027\" data-start=\"4994\"\u003eStainless steel finned heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5102\" data-start=\"5028\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5050\" data-start=\"5028\"\u003eHeater Control Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5102\" data-start=\"5050\"\u003eContactless periodic pulse width modulation, SSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5161\" data-start=\"5103\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5122\" data-start=\"5103\"\u003eController Model\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5161\" data-start=\"5122\"\u003eProfessional temperature controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5203\" data-start=\"5162\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5172\" data-start=\"5162\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5203\" data-start=\"5172\"\u003eHigh color LCD touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5253\" data-start=\"5204\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5221\" data-start=\"5204\"\u003eOperation Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5253\" data-start=\"5221\"\u003eProgram mode, set value mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5340\" data-start=\"5254\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5271\" data-start=\"5254\"\u003eSetting Method\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5340\" data-start=\"5271\"\u003eColor touch human-computer interaction, Chinese\/English interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5426\" data-start=\"5341\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5356\" data-start=\"5341\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5426\" data-start=\"5356\"\u003eAnti-integral saturation PID, BTC balance temperature control mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5492\" data-start=\"5427\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5460\" data-start=\"5427\"\u003eTemperature Measurement Method\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5492\" data-start=\"5460\"\u003eGrade A armored PT100 sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5547\" data-start=\"5493\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5512\" data-start=\"5493\"\u003eDisplay Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5547\" data-start=\"5512\"\u003eTemperature: 0.01℃; Time: 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5639\" data-start=\"5548\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5578\" data-start=\"5548\"\u003eOver-Temperature Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5639\" data-start=\"5578\"\u003eIndependent overtemperature protector with shutdown alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5731\" data-start=\"5640\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5671\" data-start=\"5640\"\u003eIntegrated Testing Equipment\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5731\" data-start=\"5671\"\u003e5V30A64CH (Series 4), located on the side of the housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5752\" data-start=\"5732\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5747\" data-start=\"5732\"\u003eControl Unit\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5752\" data-start=\"5747\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5775\" data-start=\"5753\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5770\" data-start=\"5753\"\u003eNetwork Switch\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5775\" data-start=\"5770\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5846\" data-start=\"5776\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5798\" data-start=\"5776\"\u003eProgramming Control\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5846\" data-start=\"5798\"\u003eUpper computer programming control supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5946\" data-start=\"5847\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5874\" data-start=\"5847\"\u003eRefrigeration Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"5946\" data-start=\"5874\"\u003eCompressor overheating, compressor overload, compressor overpressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6072\" data-start=\"5947\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5973\" data-start=\"5947\"\u003eTest Chamber Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6072\" data-start=\"5973\"\u003eAdjustable overtemperature protection and abnormal protection of the circulating fan in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6099\" data-start=\"6073\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6087\" data-start=\"6073\"\u003eSmoke Alarm\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6099\" data-start=\"6087\"\u003eEquipped\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6174\" data-start=\"6100\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6117\" data-start=\"6100\"\u003eExhaust Device\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6174\" data-start=\"6117\"\u003eAuto starts when smoke concentration exceeds standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6287\" data-start=\"6175\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6203\" data-start=\"6175\"\u003eFire Extinguishing Device\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6287\" data-start=\"6203\"\u003eOne 8L carbon dioxide empty bottle per device, manual or automatic extinguishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6450\" data-start=\"6288\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6315\" data-start=\"6288\"\u003eOther Safety Protections\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6450\" data-start=\"6315\"\u003ePhase sequence and phase loss protection, leakage protection, overload, short circuit protection, power failure recovery protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6537\" data-start=\"6451\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6477\" data-start=\"6451\"\u003ePower Supply Conditions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6537\" data-start=\"6477\"\u003eAC (380±38) V, (50±0.5) Hz, three-phase five-wire system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6569\" data-start=\"6538\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6561\" data-start=\"6538\"\u003eGrounding Resistance\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6569\" data-start=\"6561\"\u003e\u0026lt; 4Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6645\" data-start=\"6570\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6591\" data-start=\"6570\"\u003ePower Distribution\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6645\" data-start=\"6591\"\u003e(8 kW temperature box + 0.5 kW test equipment) × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6676\" data-start=\"6646\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6664\" data-start=\"6646\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6676\" data-start=\"6664\"\u003e17 A × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6737\" data-start=\"6677\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6701\" data-start=\"6677\"\u003eOperating Environment\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6737\" data-start=\"6701\"\u003e5℃ to 35℃, ≤85% RH, 86kPa–106kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6845\" data-start=\"6738\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6759\" data-start=\"6738\"\u003eCell Specification\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6845\" data-start=\"6759\"\u003eCylindrical cell, single temperature zone 5V30A32CH (double temperature zone 64CH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"6961\" data-start=\"6846\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6870\" data-start=\"6846\"\u003eCell Placement Method\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"6961\" data-start=\"6870\"\u003eFour floors in the single temperature zone, eight floors in the double temperature zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"7028\" data-start=\"6962\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"6988\" data-start=\"6962\"\u003eCell Tray Customization\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-end=\"7028\" data-start=\"6988\"\u003eCan be customized according to needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"7105\" data-start=\"7030\"\u003e \u003c\/p\u003e\n\u003ch3 data-end=\"7123\" data-start=\"7107\" data-section-id=\"wggvqn\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-end=\"7180\" data-start=\"7125\"\u003eThis all-in-one battery testing system is suitable for:\u003c\/p\u003e\n\u003cul data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"7632\" data-start=\"7182\"\u003e\n\u003cli data-end=\"7260\" data-start=\"7182\" data-section-id=\"1c06lh4\"\u003eBattery cell performance testing under high and low temperature conditions\u003c\/li\u003e\n\u003cli data-end=\"7327\" data-start=\"7261\" data-section-id=\"m47fk4\"\u003eCylindrical cell testing in new energy production environments\u003c\/li\u003e\n\u003cli data-end=\"7398\" data-start=\"7328\" data-section-id=\"in8oy6\"\u003eResearch institute battery validation and environmental simulation\u003c\/li\u003e\n\u003cli data-end=\"7461\" data-start=\"7399\" data-section-id=\"1608wog\"\u003eIntegrated thermal chamber and battery cell test workflows\u003c\/li\u003e\n\u003cli data-is-last-node=\"\" data-end=\"7632\" data-start=\"7462\" data-section-id=\"1t2z8oa\"\u003eSafety-focused cell testing with smoke detection, exhaust, and fire extinguishing features\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Neware","offers":[{"title":"Default Title","offer_id":41360274358330,"sku":"WGDW-400L2-70C-380V-12U-B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/WGDW-800L2-20C-380V-32U-B_dc706cd3-a34f-49c8-9136-be8b36bb8702.jpg?v=1777056058","url":"https:\/\/www.msesupplies.com\/en-de\/products\/neware-wgdw-400l2-70c-380v-12u-b-70-to-150-all-in-one-400l-battery-testing-system","provider":"MSE Supplies","version":"1.0","type":"link"}