{"product_id":"neware-ce-6002n-500v400a-ig-500v400a-battery-pack-testing-equipment-2-channels","title":"Neware CE-6002n-500V400A-IG, 500V400A battery pack testing equipment, 2 channels","description":"\u003ch2\u003eNeware CE-6002n-500V400A-IG, 500V400A battery pack testing equipment, 2 channels\u003c\/h2\u003e\n\u003ch3\u003eIntroduction\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNeware CE-6002n-500V400A-IG, 500V400A Battery Pack Testing Equipment, 2 Channels\u003c\/strong\u003e is a high-power battery pack testing system designed for charge\/discharge cycling, simulation testing, pulse testing, and DCIR analysis. With 2 independent channels, up to 500V \/ 400A per channel, and IGBT-based power control, it is suitable for battery pack research, performance validation, and demanding high-voltage, high-current testing applications.\u003c\/p\u003e\n\u003cp\u003eBuilt with four-wire sampling, TCP\/IP communication, and centralized MySQL data management, this system provides accurate control, stable operation, and flexible integration for laboratory and production environments. The equipment also supports optional AUX channels for temperature and voltage monitoring, as well as integration with environmental chambers, water chillers, and pressure fixtures.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 independent testing channels\u003c\/li\u003e\n\u003cli\u003eUp to 500V \/ 400A per channel\u003c\/li\u003e\n\u003cli\u003eIGBT power control module\u003c\/li\u003e\n\u003cli\u003eVoltage accuracy of ±0.02% FS\u003c\/li\u003e\n\u003cli\u003eCurrent accuracy of 0.05% FS\u003c\/li\u003e\n\u003cli\u003eSingle-channel output power up to 200 kW\u003c\/li\u003e\n\u003cli\u003eWhole-machine output power up to 400 kW\u003c\/li\u003e\n\u003cli\u003eFour-wire connection for accurate voltage and current sampling\u003c\/li\u003e\n\u003cli\u003eSupports charge\/discharge, simulation, pulse, and DCIR testing\u003c\/li\u003e\n\u003cli\u003eMinimum pulse time of 100 ms\u003c\/li\u003e\n\u003cli\u003eRecording frequency up to 100 Hz\u003c\/li\u003e\n\u003cli\u003eTCP\/IP communication and MySQL database support\u003c\/li\u003e\n\u003cli\u003eOptional CAN, RS485, and BMS communication\u003c\/li\u003e\n\u003cli\u003eSupports third-party integration with environmental chambers, water chillers, and pressure fixtures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCE-6002n-500V400A-IG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels Quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Parallel Connection\u003c\/td\u003e\n\u003ctd\u003eSupports max. 4 channels parallel mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply\u003c\/td\u003e\n\u003ctd\u003e3PH-AC380V ±10%, 50\/60 ±5Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e≥99% (full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi\u003c\/td\u003e\n\u003ctd\u003e≤5% (full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e2 cabinets, each cabinet 222.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2 cabinets, each cabinet 337.6 A \/ single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall System Efficiency (Max)\u003c\/td\u003e\n\u003ctd\u003e94%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e≤75 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Size (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e2 cabinets, each cabinet 1350 × 1250 × 2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 cabinets, each cabinet 1700 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Control Module Type\u003c\/td\u003e\n\u003ctd\u003eIGBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Wiring Method\u003c\/td\u003e\n\u003ctd\u003eThree-phase-four wire system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Protection\u003c\/td\u003e\n\u003ctd\u003eAnti-surge, anti-islanding, over-under-frequency, over-under-voltage, open-phase protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage and Current Sampling\u003c\/td\u003e\n\u003ctd\u003eFour-wire connection (same port for charging and discharging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003eCharge: 0V–500V; Discharge: 10V–500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Discharge Voltage\u003c\/td\u003e\n\u003ctd\u003e10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Resolution\u003c\/td\u003e\n\u003ctd\u003e24 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e2A–400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.05% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCV Cut-off Current\u003c\/td\u003e\n\u003ctd\u003e0.05% of FS (each independent range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Resolution\u003c\/td\u003e\n\u003ctd\u003e24 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Channel Output Power\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhole Machine Output Power\u003c\/td\u003e\n\u003ctd\u003e400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Response Time\u003c\/td\u003e\n\u003ctd\u003e≤5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Conversion Time\u003c\/td\u003e\n\u003ctd\u003e≤10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Step Time\u003c\/td\u003e\n\u003ctd\u003e0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e≥1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge\/Discharge Modes\u003c\/td\u003e\n\u003ctd\u003eCCC\u0026amp;CCD, CVC\u0026amp;CVD, CC-CVC\u0026amp;CC-CVD, CPC\u0026amp;CPD, CP-CVC\u0026amp;CP-CVD, CV-CRD, CRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCut-off Condition\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Δtime, Capacity, -ΔV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimulation Modes\u003c\/td\u003e\n\u003ctd\u003eCurrent, Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimulation Switch\u003c\/td\u003e\n\u003ctd\u003eSupports continuous switching between charge and discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimulation Cut-off Condition\u003c\/td\u003e\n\u003ctd\u003eTime, step line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteps File Lines\u003c\/td\u003e\n\u003ctd\u003e1,000,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Charge\/Discharge Modes\u003c\/td\u003e\n\u003ctd\u003eCurrent, Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Counts\u003c\/td\u003e\n\u003ctd\u003eUp to 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge and Discharge Switch\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Cut-off Condition\u003c\/td\u003e\n\u003ctd\u003eVoltage, ΔTime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCIR\u003c\/td\u003e\n\u003ctd\u003eDCIR by calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Protection\u003c\/td\u003e\n\u003ctd\u003eVoltage lower\/upper limit, current lower\/upper limit, delay time, etc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Protection\u003c\/td\u003e\n\u003ctd\u003eAnti-reverse connection, over-voltage, over-current, over-temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Setting Method\u003c\/td\u003e\n\u003ctd\u003eForm editing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Frequency\u003c\/td\u003e\n\u003ctd\u003e100 Hz (10 Hz when two AUX channels allocate under one main channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatabase\u003c\/td\u003e\n\u003ctd\u003eMySQL database\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Mode\u003c\/td\u003e\n\u003ctd\u003eExcel, Txt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurve Type\u003c\/td\u003e\n\u003ctd\u003eTemplates available, customization supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Test Range\u003c\/td\u003e\n\u003ctd\u003e1–65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Steps in a Single Loop\u003c\/td\u003e\n\u003ctd\u003e1000+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Nesting\u003c\/td\u003e\n\u003ctd\u003e≤10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Computer Communication Mode\u003c\/td\u003e\n\u003ctd\u003eBased on TCP\/IP protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Computer Communication Baud Rate\u003c\/td\u003e\n\u003ctd\u003e1M bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Computer Communication Baud Rate\u003c\/td\u003e\n\u003ctd\u003e10M–100M adaptive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking Mode\u003c\/td\u003e\n\u003ctd\u003eLocal area network through switches and routers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Expansion (Optional)\u003c\/td\u003e\n\u003ctd\u003eCAN, RS485, BMS communication with DBC; supports chamber, water chiller, pressure fixture integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Temperature Aux Range\u003c\/td\u003e\n\u003ctd\u003eThermocouple: -200°C to 260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Voltage Aux Range\u003c\/td\u003e\n\u003ctd\u003e0V–5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Voltage Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Humidity\u003c\/td\u003e\n\u003ctd\u003e≤70% RH (no water vapor condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e≤80% RH (no water vapor condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis battery pack testing equipment is suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBattery pack charge\/discharge testing\u003c\/li\u003e\n\u003cli\u003eCycle life evaluation\u003c\/li\u003e\n\u003cli\u003ePulse and DCIR testing\u003c\/li\u003e\n\u003cli\u003eSimulation-based battery testing\u003c\/li\u003e\n\u003cli\u003eHigh-voltage battery pack validation\u003c\/li\u003e\n\u003cli\u003eIntegrated testing with environmental chambers, water chillers, or pressure fixtures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis battery tester does \u003cstrong\u003enot\u003c\/strong\u003e include a middle machine. If required, the middle machine must be purchased separately. Please order it separately\u003c\/li\u003e\n\u003cli\u003eThe default fixture supplied with this unit is the \u003cstrong\u003eRing Connector\u003c\/strong\u003e, and the default channel cable length is 2 meters. The polymer clamp is shown in the image below.\u003cimg\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/5312d59d-507c-4bdd-9f71-9334a7702afd.png?v=1776201389\" alt=\"\" width=\"71\" height=\"107\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIf you require a different type of clamp, please contact \u003cstrong\u003eMSE Supplies\u003c\/strong\u003e directly.\u003cimg\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMSE Supplies is an authorized distributor of Neware in the USA. The product figure is for reference only. The actual product may look different based on the product configuration. \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMSE Supplies is a US-based leading supplier of\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/collections\/lithium-ion-battery-materials\" target=\"_blank\"\u003ebattery research materials and equipment\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ewith thousands of customers worldwide.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Neware","offers":[{"title":"Default Title","offer_id":41603105816634,"sku":"CE-6002N-500V400A-IG","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/NewareCE-6002n-500V400A-IG.png?v=1787159171","url":"https:\/\/www.msesupplies.com\/en-de\/products\/neware-ce-6002n-500v400a-ig-500v400a-battery-pack-testing-equipment-2-channels","provider":"MSE Supplies","version":"1.0","type":"link"}