{"product_id":"mse-pro-synchronous-thermal-analyzer-sta-tga-dsc","title":"MSE PRO Synchronous Thermal Analyzer (STA\/TGA-DSC)","description":"\u003ch2\u003e\n\u003cspan\u003eMSE PRO™ \u003c\/span\u003eSynchronous Thermal Analyzer (STA\/TGA-DSC)\u003c\/h2\u003e\n\u003cp\u003eMSE Supplies offers Synchronous Thermal Analyzers. Simultaneous Thermal Analysis (STA) combines \u003cstrong\u003eThermogravimetry (TGA)\u003c\/strong\u003e and \u003cstrong\u003eDifferential Scanning Calorimetry (DSC)\u003c\/strong\u003e in a single instrument, enabling the simultaneous measurement of mass changes and thermal effects in a sample during heating, cooling, or isothermal conditions.\u003c\/p\u003e\n\u003cp\u003eThis technique allows for the study of thermal stability, composition, and heat-related changes of materials, providing insights into mass variations with temperature or time. STA is widely utilized in research and development, process optimization, and quality control across various industries, including plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metals, and composites\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Stability\u003c\/strong\u003e: The furnace body utilizes a double-row winding of precious metal nickel-chromium alloy wire, reducing interference and ensuring excellent high-temperature resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimultaneous Testing\u003c\/strong\u003e: Supports comprehensive analysis with DSC\/DTA and TGA measurements performed simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Tray Sensor\u003c\/strong\u003e: Made from precious metal alloy wire, the tray sensor offers exceptional high-temperature resistance, oxidation resistance, and corrosion resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Heat Management\u003c\/strong\u003e: The separation of power supply and heat dissipation components from the main unit minimizes heat and vibration effects on the micro-thermal balance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser-Friendly Design\u003c\/strong\u003e: The top-opening structure simplifies operation, avoiding the need to lift the furnace body and reducing the risk of damage to the sample rod.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Thermal Insulation\u003c\/strong\u003e: The system incorporates effective insulation between the heating furnace, chassis, and micro-thermal balance, ensuring stability and measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomizable Furnace Body\u003c\/strong\u003e: The furnace body can be replaced or tailored to meet specific customer requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eController and software\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Performance Processing: Equipped with an imported ARM processor for faster sampling and processing speeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-Channel Data Collection: Features a four-channel AD system for simultaneous collection of TG signals and temperature (T) signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision Heating Control: Utilizes a PID algorithm for precise temperature control, supporting multi-stage heating and constant temperature operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote Operation: Enables USB two-way communication between the software and instrument, allowing full remote control. Instrument parameter settings, as well as start\/stop operations, can be managed via computer software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnhanced User Interface: Includes a 7-inch full-color 24-bit touch screen, providing an intuitive and improved user experience. TG calibration can be performed directly on the touch screen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 639px; height: 513px;\" width=\"538\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 267.5px;\" width=\"217\"\u003e \u003ccol style=\"width: 371.5px;\" width=\"321\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e7 inches LCD color screen display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003eRoom temperature ~1350°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eHeating Rate\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e1 – 80°C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eTemperature Control Mode\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003eTemperature rise\/fall and constant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eConstant Temperature Time\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e0 – 300 min, can be set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eCooling Time\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e15 min (1000°C to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eScale Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e1 mg – 3 g (Optional 10 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eDSC Measuring Range\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e0 – ±500 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eDSC Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e0.01 µW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e0.01 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eAtmosphere\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003eInertia, oxidability, reducibility, static, dynamic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eAtmosphere Device\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003eBuilt-in gas flow meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\" height=\"38\"\u003e\n\u003ctd style=\"height: 39.2px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"38\"\u003eSoftware\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 39.2px;\" width=\"321\" class=\"xl87\"\u003e4-in-1 operating software (switchable to DSC, DTA, TGA, STA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eData Interface\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e110V\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 163pt;\" width=\"217\" class=\"xl87\" height=\"19\"\u003eSize\u003c\/td\u003e\n\u003ctd style=\"width: 241pt; height: 19.6px;\" width=\"321\" class=\"xl87\"\u003e500 × 400 × 430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePacking List\u003c\/h3\u003e\n\u003ctable height=\"215\" style=\"border-collapse: collapse; width: 649px;\" width=\"468\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 344.5px;\" width=\"254\"\u003e \u003ccol style=\"width: 304.5px;\" width=\"214\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 190pt;\" width=\"254\" height=\"19\"\u003eHost machine\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 160pt;\" width=\"214\"\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt;\" height=\"19\"\u003eCD with installation system\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt;\" height=\"19\"\u003ePower Cord\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt;\" height=\"19\"\u003eData line\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt;\" height=\"19\"\u003eSample crucible\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e200 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt;\" height=\"19\"\u003e10A fuse\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt;\" height=\"19\"\u003eOperational manual\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"MSE Supplies","offers":[{"title":"Default Title","offer_id":40741226774586,"sku":"MA0667","price":36299.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Screenshot2024-12-17092238.png?v=1734452621","url":"https:\/\/www.msesupplies.com\/en-de\/products\/mse-pro-synchronous-thermal-analyzer-sta-tga-dsc","provider":"MSE Supplies","version":"1.0","type":"link"}