{"product_id":"mse-pro-450l-programmed-salt-spray-testing-machine","title":"MSE PRO 450L Programmed Salt Spray Testing Machine","description":"\u003ch2\u003e\u003cspan data-mce-fragment=\"1\"\u003eMSE PRO™ 450L Programmed Salt Spray Testing Machine\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe MSE PRO™ Programmed Salt Spray Testing Machine is \u003cstrong\u003edesigned for conducting accelerated corrosion tests on materials and coatings. This highly reliable and precise equipment enables users to simulate harsh environmental conditions, such as salt mist, to evaluate a material’s resistance to corrosion.\u003c\/strong\u003e Equipped with an advanced temperature control system, this machine supports a wide range of testing standards, making it suitable for various industries, including automotive, aerospace, and electronics. It is engineered for user safety, with strict limitations on test sample types to prevent hazardous scenarios during operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Precision Temperature Control\u003c\/strong\u003e: The machine maintains precise temperature control, with a deviation of ±1.0°C and uniformity within 2°C, ensuring consistent and reliable test results.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Testing Conditions\u003c\/strong\u003e: Users can adjust spray times from as short as 1 second to as long as 9999 hours, allowing for tailored testing protocols across a wide range of corrosion testing standards, including NSS and CASS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge Capacity Chamber\u003c\/strong\u003e: With an internal volume of 450 liters, the machine accommodates a variety of test sample sizes, making it ideal for both small and large-scale tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Corrosion Standards Compliance\u003c\/strong\u003e: The machine adheres to numerous international testing standards such as GB, ASTM, and JIS, ensuring its suitability for global applications in various industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser-Friendly Design\u003c\/strong\u003e: Equipped with easy-to-use controls and a clear operational interface, the machine is designed for user safety and efficiency. It prevents hazardous test conditions by restricting the use of toxic or reactive substances during tests.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eBrand:\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eMSE PRO\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-fragment=\"1\" data-mce-style=\"font-size: 0.875rem;\"\u003e™ \u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e MSE Supplies LLC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMSE Supplies offers a variant of Salt Spray Testing Machine\u003c\/strong\u003e\u003cstrong\u003e.\u003c\/strong\u003e\u003cstrong\u003e\u003cstrong\u003e \u003c\/strong\u003ePlease \u003ca rel=\"noopener\" href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\" target=\"_blank\" data-mce-href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\"\u003econtact us\u003c\/a\u003e for more information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 249px;\" width=\"100%\" data-mce-style=\"width: 100%; height: 249px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003eSKU#\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e\u003cstrong\u003eMA3282\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003e\u003cspan\u003eInner Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e450 L,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.0909%;\" data-mce-style=\"width: 41.0909%;\"\u003e\u003cspan\u003eInner Chamber Size (W x D x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%;\" data-mce-style=\"width: 57.4545%;\"\u003e1000 x 650 x 700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003e\u003cspan\u003eExtemal Size (W x D x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e1700 x 1400 x 1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14px;\" data-mce-style=\"height: 14px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 14px;\" data-mce-style=\"width: 41.0909%; height: 14px;\"\u003eTest Environmental Condition\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 14px;\" data-mce-style=\"width: 57.4545%; height: 14px;\"\u003eAmbient temperature is + 25°C, relative humidity is 85% RH, with no sample in the test chamber.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003e\u003cspan\u003eSaturating Barrel Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003eRT+5 °C ~ 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003eTemperature Control Performance\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e\n\u003cp\u003eTemperature deviation: ±1.0 °C\u003c\/p\u003e\n\u003cp\u003eTemperature uniformity: 2 °C\u003c\/p\u003e\n\u003cp\u003eTemperature fluctuation: ±0.5 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003eLaboratory Heating Rate\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003eRoom temperature to +50°C in ≤45 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26px;\" data-mce-style=\"height: 26px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 26px;\" data-mce-style=\"width: 41.0909%; height: 26px;\"\u003eSaturating Barrel Heating Rate\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 26px;\" data-mce-style=\"width: 57.4545%; height: 26px;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003eRoom temperature to +63°C in ≤45 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e\u003cspan\u003e110 V or 220V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003eTest Condition\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" width=\"220\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNSS or AASS Test\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest temperature: 35°C\u003c\/li\u003e\n\u003cli\u003eSaturation barrel temperature: 47°C\u003c\/li\u003e\n\u003cli\u003eSpray time: 1 minute to 9999 hours, adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCASS Test\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest temperature: 50°C\u003c\/li\u003e\n\u003cli\u003eSaturation barrel temperature: 63°C\u003c\/li\u003e\n\u003cli\u003eSpray time: 1 minute to 9999 hours, adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolution pH Value\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNSS: 6.0 to 7.0\u003c\/li\u003e\n\u003cli\u003eAASS\/CASS: 3.0 to 3.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpray pH Value\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNSS: 6.5 to 7.2\u003c\/li\u003e\n\u003cli\u003eAASS\/CASS: 3.1 to 3.3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRunning time: 1 second to 9999 hours, freely adjustable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpray time: 1 second to 9999 hours, adjustable; interval period: 1 second to 9999 hours adjustable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: Carbon dioxide loss in the spray solution may cause a change in pH value. To avoid this, heat the solution to above 35°C before introducing it to the machine or prepare the solution carefully to prevent pH change.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003eSalt Mist Settlement\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e1 to 2 ml\/h\/80cm² (collected for at least 16 hours and averaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\" data-mce-style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 41.0909%; height: 19px;\" data-mce-style=\"width: 41.0909%; height: 19px;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eSpray Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%; height: 19px;\" data-mce-style=\"width: 57.4545%; height: 19px;\"\u003e70 to 170 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.0909%;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eSample Placement Angle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%;\"\u003e20 ± 5° to the vertical plane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.0909%;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eStandards \u0026amp; Execution Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4545%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003col\u003e\n\u003cli\u003eGB\/T2423.17-2008\/IEC60068-2-11-1981 Salt Spray Test Method\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003col start=\"2\"\u003e\n\u003cli\u003eASTM B117-90 Salt Spray Test\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003col start=\"3\"\u003e\n\u003cli\u003eASTM B368-09 Standard Method for Copper-Accelerated Acetic Acid Salt Spray Test (CASS Test)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003col start=\"4\"\u003e\n\u003cli\u003eJIS H8502-1999 Salt Spray Test\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003col start=\"5\"\u003e\n\u003cli\u003eGB\/T10587-2006 Salt Spray Test Equipment\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003col start=\"6\"\u003e\n\u003cli\u003eGB\/T10125-2012\/ISO 9227-2006\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MSE Supplies","offers":[{"title":"110V","offer_id":40836556193850,"sku":"MA3282","price":24499.95,"currency_code":"USD","in_stock":true},{"title":"220V","offer_id":40836556226618,"sku":"MA3281","price":24142.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/copy_d6e81604-dded-4594-b61f-1ad13a6a95af.jpg?v=1730344630","url":"https:\/\/www.msesupplies.com\/en-de\/products\/mse-pro-450l-programmed-salt-spray-testing-machine","provider":"MSE Supplies","version":"1.0","type":"link"}