{"product_id":"mse-pro-30l-h-laboratory-water-purifier","title":"MSE PRO 30L\/H Laboratory Water Purifier","description":"\u003ch2\u003e\u003cspan\u003eMSE PRO™ 30L\/H Laboratory Water Purifier\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe MSE PRO Laboratory Water Purifier delivers high-purity water ideal for scientific and analytical applications. Featuring nano RO membrane filtration and intelligent automation, this system ensures optimal performance with minimal maintenance. It meets national water quality standards and incorporates safety and usability enhancements, making it an essential tool for modern laboratories. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"694\" data-start=\"586\"\u003e\n\u003cstrong data-end=\"606\" data-start=\"586\"\u003eNano RO Membrane\u003c\/strong\u003e: Effectively filters tiny particles and contaminants, ensuring ultra-pure water output.\u003c\/li\u003e\n\u003cli data-end=\"789\" data-start=\"698\"\u003e\n\u003cstrong data-end=\"727\" data-start=\"698\"\u003eFully Automatic Operation\u003c\/strong\u003e: Simple one-key start for seamless and user-friendly control.\u003c\/li\u003e\n\u003cli data-end=\"909\" data-start=\"793\"\u003e\n\u003cstrong data-end=\"823\" data-start=\"793\"\u003ePressure Protection System\u003c\/strong\u003e: Equipped with both high and low-pressure protection for enhanced operational safety.\u003c\/li\u003e\n\u003cli data-end=\"1020\" data-start=\"913\"\u003e\n\u003cstrong data-end=\"933\" data-start=\"913\"\u003eConsumable Alarm\u003c\/strong\u003e: Built-in alerts notify when filter elements or other consumables require replacement.\u003c\/li\u003e\n\u003cli data-end=\"1146\" data-start=\"1024\"\u003e\n\u003cstrong data-end=\"1057\" data-start=\"1024\"\u003eStandard Compliance \u0026amp; Display\u003c\/strong\u003e: Meets GB\/T6682-2008 standards with an LCD display to show real-time water quality data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eBrand:\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eMSE PRO\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e™\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e MSE Supplies LLC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eMSE Supplies offers a \u003cspan\u003evariety\u003c\/span\u003e of Laboratory Water Purifiers.\u003c\/strong\u003e\u003cstrong\u003e Please \u003ca href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\" rel=\"noopener\" target=\"_blank\"\u003econtact us\u003c\/a\u003e for more information.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 553px; height: 516.207px;\" width=\"488\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 172px;\" width=\"151\"\u003e \u003ccol style=\"width: 146px;\" width=\"173\"\u003e \u003ccol style=\"width: 234px;\" width=\"164\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px; width: 113pt;\" width=\"151\" class=\"xl66\" height=\"20\"\u003eSKU#\u003c\/td\u003e\n\u003ctd style=\"width: 253pt; text-align: center; height: 19.9908px;\" width=\"337\" class=\"xl70\" colspan=\"2\"\u003e\u003cstrong\u003eBB2791\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1851px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 39.1851px; width: 243pt;\" width=\"324\" class=\"xl69\" height=\"20\" colspan=\"2\"\u003eWater Output Type\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"height: 39.1851px;\"\u003eRO water outlet*1 and DI water outlet*1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003eWater Output Speed\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e30 L\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003ePurifying Procedure\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"height: 19.9908px;\"\u003ePF+AC+RO+DI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.3701px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 78.3701px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003eWater Supply Requirement\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 78.3701px;\"\u003eWhen working, the inlet water pressure is 0.1-0.3Mpa, and the water quality meets the requirements of GB5749, 15 - 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.9969px;\" height=\"40\"\u003e\n\u003ctd style=\"height: 39.9969px;\" class=\"xl66\" height=\"40\" colspan=\"2\"\u003eEnvironmental Requirements\u003c\/td\u003e\n\u003ctd style=\"width: 123pt; height: 39.9969px;\" width=\"164\" class=\"xl68\"\u003eTemperature 15 - 35°C \u003cbr\u003eRelative Humidity ≤80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5925px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 99.5557px;\" class=\"xl66\" height=\"100\" rowspan=\"5\"\u003eDI Water Quality\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.5925px;\"\u003eResistivity\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.5925px;\"\u003e10-18.25MΩ.cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\"\u003eConductivity\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e0.055-0.1μs\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\"\u003eHeavy metal\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e\u0026lt;0.1ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\"\u003eParticle\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e\u0026lt;1\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl67\" height=\"20\"\u003eBacteria\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e\u0026lt;0.1cfu\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5925px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 80.7751px;\" class=\"xl66\" height=\"62\" rowspan=\"3\"\u003eRO Water Quality\u003c\/td\u003e\n\u003ctd class=\"xl65\" style=\"height: 19.5925px;\"\u003eIon rejection rate\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.5925px;\"\u003e96%-99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9975px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 21.9975px;\" class=\"xl65\" height=\"22\"\u003eOrganic rejection rate\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 21.9975px;\"\u003e\u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1851px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 39.1851px;\" class=\"xl65\" height=\"20\"\u003eParticles and bacteria rejection rate\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 39.1851px;\"\u003e\u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003eFlow Rate\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e1750ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9908px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.9908px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003eConsumption\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 19.9908px;\"\u003e113W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1851px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 39.1851px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 39.1851px;\"\u003eAC220V (Standard); AC110V (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1851px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 39.1851px;\" class=\"xl66\" height=\"20\" colspan=\"2\"\u003eStandard Configuration\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"height: 39.1851px;\"\u003eMain body , 25Lwater tank, accessory pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MSE Supplies","offers":[{"title":"110V","offer_id":40855925162042,"sku":"BB2791","price":1639.95,"currency_code":"USD","in_stock":true},{"title":"220V","offer_id":40855925194810,"sku":"BB2792","price":1639.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/SCSJ-II-30L.jpg?v=1745472659","url":"https:\/\/www.msesupplies.com\/en-de\/products\/mse-pro-30l-h-laboratory-water-purifier","provider":"MSE Supplies","version":"1.0","type":"link"}