{"product_id":"gasera-one-hydrogen-fluoride-gas-analyzer","title":"Gasera One Hydrogen Fluoride Gas Analyzer","description":"\u003ch2\u003eGasera One Hydrogen Fluoride Gas Analyzer\u003c\/h2\u003e\n\u003cp\u003eMSE Supplies is an authorized distributor of Gasera Products in the US. \u003cstrong\u003e\u003cem\u003ePlease\u003cspan\u003e fill out the application questionnaire and \u003c\/span\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e\u003cspan\u003e to discuss the application and configurations.\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eIntroduction\u003c\/h3\u003e\n\u003cp style=\"text-align: left;\"\u003eHydrogen fluoride (HF) is a colorless, highly irritating, toxic and corrosive gas and can exist as a fuming liquid. HF is a severe irritant to the eyes, skin, and nasal passages already at 2 ppm levels. It may penetrate easily and quickly through the skin or lungs and into the tissues in the body causing serious damage to cells and organs.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eHF is a common industrial compound used in manufacturing of fluorine, superacids, refrigerants, pharmaceuticals, polymers, among others. The continuous monitoring of low ppb levels of HF is needed to ensure product quality, reduce waste and for occupational and environmental safety\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eGASERA ONE HF analyzer is based on combining ultrasensitive cantilever enhanced photoacoustic detection technology with Tunable Diode Laser source operating at a NIR fundamental spectral absorption line of hydrogen fluoride. This combination provides enough sensitivity to reliably measure ambient background levels of hydrogen fluoride. It also gives an exceptionally high level of stability with a recommended re-calibration period of 12 months, offering a low total cost of ownership.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelective monitoring of hydrogen fluoride with below 0.5 ppb detection limit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eResponse time user configurable from 10 seconds to a few minutes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDynamic range of 0 - 10 ppm and stable operation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas cell stabilized to 50 °C and 300 mbar to avoid drifts due to changes in environmental conditions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow sample volume (few ml)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRecommended re-calibration interval of 12 months\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser configurable monitoring tasks\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in display presents results both numerically and graphically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Performance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDetection Limit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 0.5 ppb with 60 s response time\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResponse Time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 seconds to several minutes (configurable)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDynamic Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0 - 10 ppm. HF concentrations above 15 ppm will damage the product\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRepeatability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 1% of measured value in operational conditions at the calibration concentration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Limited by the calibration gas accuracy\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No drift due to ambient temperature or pressure variations within recommended working conditions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eSystem Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eForm Factor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19” 3U rack-mount \/ tabletop unit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48.4 × 13.9 × 44 cm (19.1 × 5.5 × 17.3 in)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ~13 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDisplay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in computer with 7” WSVGA screen\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInternal Gas Volume:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30 ml\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eData Storage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥ 1 year continuous monitoring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eOperating Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTemperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHumidity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 750–1050 mbar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDust\/water resistance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20 (IEC 529)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSample Gas Conditions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTemperature: 0°C to +49°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHumidity: Up to 99% RH (non-condensing, temperature dependent)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow Rate: ~0.6 L\/min\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParticle Size: \u0026lt; 1 µm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eElectrical \u0026amp; Interfaces\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInput Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 90–264 VAC, 47–63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Max. 75 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInterfaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ethernet, USB, optional Serial\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProtocols:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e MODBUS, AK protocol\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Current or voltage signal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eCompliance \u0026amp; Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLow Voltage Directive 2014\/35\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEMC Directive 2004\/108\/EC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS 2 Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum smelters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhosphate fertilizer plants\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHazardous waste treatment and disposal\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMetal refining\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluorocarbon and fluoride production\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePetroleum industry\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCleanroom Occupational safety\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated publications:\u003c\/h3\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-updated-hr-color\" id=\"model-response-message-contentr_2236d61e5ada7fdc\" dir=\"ltr\"\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-luminous-fast-follows enable-updated-hr-color\" id=\"model-response-message-contentr_d641e729ee2f97ff\" dir=\"ltr\"\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/Sub-parts-per-trillion-level-sensitivity-in-trace-gas-detection-by-cantilever-enhanced-photoacoustic-spectroscopy.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eSub-parts-per-trillion level sensitivity in trace gas detection by cantilever-enhanced photoacoustic spectroscopy\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering enable-updated-hr-color\" id=\"model-response-message-contentr_b6dae140b3eeb6c5\" dir=\"ltr\"\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003ca rel=\"noopener\" href=\"https:\/\/gasera.fi\/wp-content\/uploads\/2015\/12\/PAS_GasAnalysisWithCantileverMicrophone_ApplSpectrosRew_2007.pdf\" class=\"ng-star-inserted\" target=\"_blank\"\u003eApplied Spectroscopy Reviews (2007): Photoacoustic Gas Analysis Using Interferometric Cantilever Microphone\u003c\/a\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp\u003eIf you are interested in other gas types or multi-gas analyzers, please \u003cstrong\u003e\u003cem\u003e\u003ca href=\"https:\/\/support.msesupplies.com\/hc\/en-us\/\"\u003econtact us\u003c\/a\u003e \u003c\/em\u003e\u003c\/strong\u003eabout your application: \u003c\/p\u003e\n\u003cp\u003e• Formaldehyde\u003cbr\u003e• Greenhouse gases\u003cbr\u003e• HF, HCl, HCN, SO2, NO2, EtO\u003cbr\u003e• SF6, NOVEC\u003cbr\u003e• CF4, PFCs\u003cbr\u003e• Benzene\u003cbr\u003e• Many more!\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Gasera","offers":[{"title":"Default Title","offer_id":41461840019514,"sku":"GASERA ONE HF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/GASERAONEHF_00d7df32-5a3e-4a4b-84c8-b6b3286cb76f.png?v=1781740625","url":"https:\/\/www.msesupplies.com\/en-de\/products\/gasera-one-hydrogen-fluoride-gas-analyzer","provider":"MSE Supplies","version":"1.0","type":"link"}