{"title":"Turbidity Meters","description":"","products":[{"product_id":"mse-pro-laboratory-advanced-benchtop-turbidity-meter","title":"MSE PRO Laboratory Advanced Benchtop Turbidity Meter","description":"\u003ch3\u003eMSE PRO™ Laboratory Advanced Benchtop Turbidity Meter\u003c\/h3\u003e\n\u003cp\u003eA turbidity meter is a device used to measure the turbidity of water. The turbidity of the water sample is determined by measuring the transmitted light intensity, scattered light intensity, and either the incident light intensity or the ratio of transmitted light intensity to scattered light intensity. This instrument is widely used in various fields such as beverage and food production, water quality monitoring, pharmaceuticals, and biotechnology.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e850nm LED light source\u003c\/li\u003e\n\u003cli\u003eNephelometric principle with 90° detection\u003c\/li\u003e\n\u003cli\u003e2 photodiodes to ensure high accuracy\u003c\/li\u003e\n\u003cli\u003e1-6 points calibration By Formazin standards or zero water\u003c\/li\u003e\n\u003cli\u003eData capacity of up to 2000 sets (GLP-compliant).\u003c\/li\u003e\n\u003cli\u003eData stored can be transferred into the computer by USB or RS-232 communication interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMSE Supplies\u003c\/strong\u003e also provides various benchtop and pocket analyzers for pH\/mV\/Conductivity\/Temperature\/OPR\/Turbidity\/Salinity measurement. Please contact us for more information.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 655px;\" height=\"515\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 373.281px;\"\u003eSKU#\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003eMA0838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 373.281px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e110VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd rowspan=\"4\" style=\"width: 175.98px;\"\u003eMeasuring Unit\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 191.676px;\"\u003eMeasuring Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e\n\u003cp\u003e(0-20.00) NTU,\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e(20.0-200.0) NTU,\u003c\/p\u003e\n\u003cp\u003e(200-1000) NTU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 72px;\"\u003e\n\u003ctd style=\"width: 191.676px;\"\u003eAccuracy\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e\u003cspan\u003e±2% of reading +0.02 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 191.676px;\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e\u003cspan\u003e≤0.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 191.676px;\"\u003eFluctuation\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e\u003cspan\u003e±0.5%FS\/30min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 373.281px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e330mm×250mm×130mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 373.281px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 266.832px;\"\u003e2.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReference:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/doi.org\/10.1016\/0032-9592(95)00002-X\" target=\"_blank\"\u003eGuillermo R. Castro, Eduardo P. Andribet, Luis M. Ducrey, Oscar A. Garro, Faustino Siñeriz, Modelling and operation of a turbidity-meter for on-line monitoring of microbial growth in fermenters, Process Biochemistry, Volume 30, Issue 8, 1995, Pages 767-772, ISSN 1359-5113.\u003c\/a\u003e\u003c\/p\u003e","brand":"MSE Supplies LLC","offers":[{"title":"Default Title","offer_id":39958182559802,"sku":"MA0838","price":2199.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/Turbiditymeter.jpg?v=1688677662"},{"product_id":"mse-pro-laboratory-high-performance-benchtop-turbidity-meter","title":"MSE PRO Laboratory High Performance Benchtop Turbidity Meter","description":"\u003ch2\u003eMSE PRO™ Laboratory High Performance Benchtop Turbidity Meter\u003c\/h2\u003e\n\u003ch3\u003eGeneral Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e7” colorful touchscreen.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTungsten lamp light source met USEPA 180.1 requirement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3 photodiodes to ensure high accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e1-8 points calibration using\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eFormazin standards or zero water.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutoranging from 0-4000 NTUs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eData Storage\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ecapacity of 1000 sets (GLP-compliant).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData stored can be transferred into the computer by USB or RS-232 communication interface.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eReset feature automatically resumes all settings back to factory default options.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"513\" style=\"border-collapse: collapse; width: 552px; box-sizing: border-box; word-break: break-word; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"118\" style=\"width: 131px;\"\u003e \u003ccol width=\"151\" style=\"width: 164px;\"\u003e \u003ccol width=\"244\" style=\"width: 257px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl68\" width=\"269\" style=\"height: 14.25pt; width: 202pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-left: none; width: 183pt;\"\u003eMA0875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"6\" height=\"131\" class=\"xl66\" width=\"118\" style=\"height: 98.25pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eMeasuring Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"3\" class=\"xl66\" width=\"151\" style=\"border-top: none; width: 113pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(0.000~20.00) NTU,\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.0pt;\"\u003e\n\u003ctd height=\"36\" class=\"xl66\" width=\"244\" style=\"height: 27.0pt; border-top: none; border-left: none; width: 183pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(20.01~200.0) NTU,\u003cspan class=\"font6\" style=\"box-sizing: border-box; word-break: break-word;\"\u003e \u003c\/span\u003e\u003cspan class=\"font5\" style=\"box-sizing: border-box; word-break: break-word;\"\u003e(200~2000) NTU,\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"244\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 183pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(2001~4000) NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±6%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e≤0.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eFluctuation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±0.5% FS\/30min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"2\" height=\"55\" class=\"xl66\" width=\"118\" style=\"height: 41.25pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eGeneral\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top: none; border-left: none;\"\u003ePower Supplies\u003c\/td\u003e\n\u003ctd class=\"xl67\" style=\"border-top: none; border-left: none;\"\u003e110VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.0pt;\"\u003e\n\u003ctd height=\"36\" class=\"xl66\" width=\"151\" style=\"height: 27.0pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eDimension (mm)\u0026amp; Weight (kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e358×323×160, 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eMSE Supplies \u003c\/strong\u003eoffers a variety of electrochemical meters \u0026amp; analyzers, including both benchtop and handheld models, to suit different applications and requirements. Please \u003c\/span\u003e\u003cstrong\u003e\u003ca style=\"font-size: 0.875rem;\" href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\" rel=\"noopener\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e to discuss your needs.\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies LLC","offers":[{"title":"Default Title","offer_id":40849748230202,"sku":"MA0875","price":2451.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MA0875.jpg?v=1744818875"},{"product_id":"mse-pro-laboratory-standard-benchtop-turbidity-meter","title":"MSE PRO Laboratory Standard Benchtop Turbidity Meter","description":"\u003ch2\u003eMSE PRO™ Laboratory Standard Benchtop Turbidity Meter\u003c\/h2\u003e\n\u003ch3\u003eGeneral Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e850nm LED light Source.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUses Nephelometric principle with 90° detection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeets ISO 7027 and offers consistent light source for higher accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable turbidity units, including the NTU, FNU and EBC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSettable parameters, including\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003euser ID, number of calibration points, data and time, etc.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1-3 points calibration using Formazin standards or zero water.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAutoranging from 0-200 NTU.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"513\" style=\"border-collapse: collapse; width: 385pt; box-sizing: border-box; word-break: break-word; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"118\" style=\"mso-width-source: userset; mso-width-alt: 3776; width: 89pt;\"\u003e \u003ccol width=\"151\" style=\"mso-width-source: userset; mso-width-alt: 4832; width: 113pt;\"\u003e \u003ccol width=\"244\" style=\"mso-width-source: userset; mso-width-alt: 7808; width: 183pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl66\" width=\"269\" style=\"height: 14.25pt; width: 202pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"244\" style=\"border-left: none; width: 183pt;\"\u003eMA0876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"5\" height=\"95\" class=\"xl65\" width=\"118\" style=\"height: 71.25pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eMeasuring Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl65\" width=\"151\" style=\"border-top: none; width: 113pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(0~20.00) NTU,\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"244\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 183pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(20.0~200.0) NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±2% of reading+0.02NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e≤1.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eFluctuation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±1.0% FS\/30min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"2\" height=\"55\" class=\"xl65\" width=\"118\" style=\"height: 41.25pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eGeneral\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top: none; border-left: none;\"\u003ePower Supplies\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top: none; border-left: none;\"\u003e110VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.0pt;\"\u003e\n\u003ctd height=\"36\" class=\"xl65\" width=\"151\" style=\"height: 27.0pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eDimension (mm)\u0026amp; Weight (kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e330×250×130, 2.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eMSE Supplies \u003c\/strong\u003eoffers a variety of electrochemical meters \u0026amp; analyzers, including both benchtop and handheld models, to suit different applications and requirements. Please \u003c\/span\u003e\u003cstrong\u003e\u003ca style=\"font-size: 0.875rem;\" href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\" rel=\"noopener\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e to discuss your needs.\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies LLC","offers":[{"title":"Default Title","offer_id":40850351685690,"sku":"MA0876","price":1157.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MA0876.jpg?v=1744868110"},{"product_id":"mse-pro-laboratory-advanced-handheld-turbidity-meter","title":"MSE PRO Laboratory Advanced Handheld Turbidity Meter","description":"\u003ch2\u003eMSE PRO™ Laboratory Advanced Handheld Turbidity Meter\u003c\/h2\u003e\n\u003ch3\u003eGeneral Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e850nm LED light Source.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUses Nephelometric principle with 90° detection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeets ISO 7027 and offers consistent light source for higher accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable turbidity units, including the NTU, FNU and EBC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSettable parameters, including\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003euser ID, number of calibration points, data and time, etc.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto-power-off feature effectively extends the battery usage time.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 photodiodes to ensure high accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1-6 points calibration using Formazin standards or zero water.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutoranging from 0-1000 NTU.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData capacity of up to 2000 sets (GLP-compliant).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eData stored can be transferred into the computer by USB or RS-232 communication interface.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"513\" style=\"border-collapse: collapse; width: 551px; box-sizing: border-box; word-break: break-word; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"118\" style=\"width: 130.667px;\"\u003e \u003ccol width=\"151\" style=\"width: 163.667px;\"\u003e \u003ccol width=\"244\" style=\"width: 256.667px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl68\" width=\"269\" style=\"height: 14.25pt; width: 202pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-left: none; width: 183pt;\"\u003eMA0877\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"7\" height=\"133\" class=\"xl67\" width=\"118\" style=\"height: 99.75pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eMeasuring Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"3\" class=\"xl67\" width=\"151\" style=\"border-top: none; width: 113pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(0~20.00) NTU,\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"244\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 183pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(20.0~200.0) NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"244\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 183pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(200~1000) NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e0.01NTU, 0.1NTU, 1NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±2% of reading+0.02NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e≤0.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eFluctuation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±0.5% FS\/30min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"2\" height=\"55\" class=\"xl67\" width=\"118\" style=\"height: 41.25pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eGeneral\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003ePower Supplies\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003e110VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.0pt;\"\u003e\n\u003ctd height=\"36\" class=\"xl67\" width=\"151\" style=\"height: 27.0pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eDimension (mm)\u0026amp; Weight (kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e100×220×80,0.8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eMSE Supplies \u003c\/strong\u003eoffers a variety of electrochemical meters \u0026amp; analyzers, including both benchtop and handheld models, to suit different applications and requirements. Please \u003c\/span\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\" style=\"font-size: 0.875rem;\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e to discuss your needs.\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies LLC","offers":[{"title":"Default Title","offer_id":40850353193018,"sku":"MA0877","price":1217.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MA0877.jpg?v=1744868573"},{"product_id":"mse-pro-laboratory-standard-handheld-turbidity-meter","title":"MSE PRO Laboratory Standard Handheld Turbidity Meter","description":"\u003ch2\u003eMSE PRO™ Laboratory Standard Handheld Turbidity Meter\u003c\/h2\u003e\n\u003ch3\u003eGeneral Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e850nm LED light Source.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUses Nephelometric principle with 90° detection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeets ISO 7027 and offers consistent light source for higher accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable turbidity units, including the NTU, FNU and EBC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSettable parameters, including\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003euser ID, number of calibration points, data and time, etc.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto-power-off feature effectively extends the battery usage time.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1-3 points calibration using Formazin standards or zero water.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAutoranging from 0-200 NTU.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"513\" style=\"border-collapse: collapse; width: 555px; box-sizing: border-box; word-break: break-word; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"118\" style=\"width: 132px;\"\u003e \u003ccol width=\"151\" style=\"width: 165px;\"\u003e \u003ccol width=\"244\" style=\"width: 258px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl68\" width=\"269\" style=\"height: 14.25pt; width: 202pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"244\" style=\"border-left: none; width: 183pt;\"\u003eMA0878\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"6\" height=\"114\" class=\"xl67\" width=\"118\" style=\"height: 85.5pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eMeasuring Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"151\" style=\"border-top: none; width: 113pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(0~20.00) NTU,\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"244\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 183pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e(20.0~200.0) NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e0.01NTU, 0.1NTU, 1NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±2% of reading+0.02NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e≤1.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.25pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eFluctuation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e±1.0% FS\/30min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt; box-sizing: border-box; word-break: break-word;\"\u003e\n\u003ctd rowspan=\"2\" height=\"55\" class=\"xl67\" width=\"118\" style=\"height: 41.25pt; border-top: none; width: 89pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eGeneral\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003ePower Supplies\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003e110VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.0pt;\"\u003e\n\u003ctd height=\"36\" class=\"xl67\" width=\"151\" style=\"height: 27.0pt; border-top: none; border-left: none; width: 113pt;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003eDimension (mm)\u0026amp; Weight (kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"244\" style=\"border-top: none; border-left: none; width: 183pt; box-sizing: border-box; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; word-break: break-word;\"\u003e100×220×80,0.8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eMSE Supplies \u003c\/strong\u003eoffers a variety of electrochemical meters \u0026amp; analyzers, including both benchtop and handheld models, to suit different applications and requirements. Please \u003c\/span\u003e\u003cstrong\u003e\u003ca style=\"font-size: 0.875rem;\" href=\"https:\/\/www.msesupplies.com\/pages\/contact-us-page\" rel=\"noopener\" target=\"_blank\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e to discuss your needs.\u003c\/span\u003e\u003c\/p\u003e","brand":"MSE Supplies LLC","offers":[{"title":"Default Title","offer_id":40850354569274,"sku":"MA0878","price":629.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/MA0878.jpg?v=1744868995"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/collections\/Turbiditymeter_160x160_c1315db5-da09-4b14-b65c-d788307430d0.jpg?v=1769048854","url":"https:\/\/www.msesupplies.com\/collections\/turbidity-meters.oembed","provider":"MSE Supplies","version":"1.0","type":"link"}