{"title":"Hypoxia Workstations","description":"","products":[{"product_id":"maworde-large-hypoxia-workstation-support-cell-culture-research-under-hypoxic-conditions","title":"MAWORDE Large Hypoxia Workstation - Support Cell Culture Research Under Hypoxic Conditions","description":"\u003ch2\u003eMAWORDE Large Hypoxia Workstation - Support Cell Culture Research Under Hypoxic Conditions\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe DY-XL is a large hypoxia workstation designed to balance space efficiency with experimental precision, integrating operation, incubation, and observation in a single system. It enables simulation of in vivo hypoxic microenvironments and supports stable cell culture and research under controlled hypoxic conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"9826b31\" class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-44a1bca elementor-widget elementor-widget-text-editor\" data-id=\"44a1bca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003ch3\u003eKey Specification:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-1c21ac1 elementor-widget elementor-widget-text-editor\" data-id=\"1c21ac1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cp\u003eOur workstation ensures precise, reliable culture conditions with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"144\" data-end=\"165\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"217\" data-end=\"239\" data-is-only-node=\"\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–20.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control\u003c\/strong\u003e: Room humidity to 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control\u003c\/strong\u003e: 3°C above ambient up to 45°C, in 0.1°C increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range\u003c\/strong\u003e: 0.00 – 0.50 kPa, in 0.01kPa increments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003ePrecise O\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; CO\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003eControl\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"7706630\" class=\"elementor-element elementor-element-7706630 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul data-end=\"459\" data-start=\"94\"\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments (upgradeable to 0–60.0%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cstrong data-end=\"473\" data-start=\"442\"\u003eOptional Built-in Air Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for an external compressed air source (O₂ control range: 0.1%–18%)\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"598\" data-start=\"568\"\u003eOptional Anaerobic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables integrated hypoxia\/anaerobic dual-mode operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-A.jpg?v=1770741479\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-f6f81d1 elementor-widget elementor-widget-heading\" data-id=\"f6f81d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSeamless Entry System (SES)\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-d76275d elementor-widget elementor-widget-text-editor\" data-id=\"d76275d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eRapid sleeve evacuation establishes an anaerobic barrier within\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"677\" data-end=\"691\"\u003e12 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eMaintains continuous and stable hypoxic conditions during routine operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"759\" data-end=\"851\"\u003e\n\u003cp data-start=\"761\" data-end=\"851\"\u003e\u003cstrong data-start=\"761\" data-end=\"785\"\u003e90° quick-open ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenable intuitive handling and improved internal space utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"852\" data-end=\"924\"\u003e\n\u003cp data-start=\"854\" data-end=\"924\"\u003eFlexible operation modes adapt to different workflows and user habits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-B.jpg?v=1770741554\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-3fda69b elementor-widget elementor-widget-heading\" data-id=\"3fda69b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eAdvanced Gas Circulation Design\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-e4a324d elementor-widget elementor-widget-text-editor\" data-id=\"e4a324d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eOptimized airflow and circulation paths ensure uniform temperature, humidity, and gas concentration distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eHigh-performance axial fans enable rapid gas exchange and even diffusion for long-term culture stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eIntegrated bent-panel construction with anti-condensation viewing window technology ensures clear visibility and enhanced durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-C.jpg?v=1770741634\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-dd1dd7f elementor-widget elementor-widget-heading\" data-id=\"dd1dd7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMulti-Stage Hypoxia Cycle\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-e2d8c4f elementor-widget elementor-widget-text-editor\" data-id=\"e2d8c4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eSupports 4, 10, or more automated gas cycling stages to suit different experimental needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eUsers can set cycle duration, gas concentrations, and the number of cycles according to their experiment requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-D.jpg?v=1770741732\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-0568282 elementor-widget elementor-widget-heading\" data-id=\"0568282\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSpecial Interlock Purge System\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\" data-id=\"10fdcf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003e\u003cstrong data-start=\"148\" data-end=\"164\" data-is-only-node=\"\"\u003eRapid purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically detects the oxygen level in the workspace and adjusts the interlock O₂ concentration to match\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003e\u003cstrong data-start=\"288\" data-end=\"305\"\u003eCustom purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows on-screen setting of O₂ purge concentration from 0 to 20.9% for special operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-E.jpg?v=1770741797\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-7872eea elementor-widget elementor-widget-heading\" data-id=\"7872eea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eHEPA Filtration \u0026amp; Pressure Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\" data-id=\"f88d3a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"96\" data-end=\"209\"\u003e\n\u003cp data-start=\"98\" data-end=\"209\"\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"109\" data-end=\"128\"\u003eH14 HEPA filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"139\" data-end=\"146\"\u003eU16\u003c\/strong\u003e) effectively protects samples from particulate contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"210\" data-end=\"333\"\u003e\n\u003cp data-start=\"212\" data-end=\"333\"\u003eHigh-response pressure relief valve precisely manages sudden pressure fluctuations, ensuring system and operator safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"334\" data-end=\"468\"\u003e\n\u003cp data-start=\"336\" data-end=\"468\"\u003eBuilt-in pressure-stabilizing water\/oil reservoir buffers continuous pressure changes, maintaining a stable experimental environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-F.jpg?v=1770741857\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"ead80d7\" class=\"elementor-element elementor-element-ead80d7 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eIntelligent Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"a432df3\" class=\"elementor-element elementor-element-a432df3 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"145\" data-start=\"96\"\u003e\n\u003cp data-end=\"145\" data-start=\"98\"\u003eAutomatic alarm for low gas cylinder pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"190\" data-start=\"146\"\u003e\n\u003cp data-end=\"190\" data-start=\"148\"\u003eReal-time chamber pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"263\" data-start=\"191\"\u003e\n\u003cp data-end=\"263\" data-start=\"193\"\u003eAutomatic leak detection with alarm and reduced gas intake frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"408\" data-start=\"326\"\u003e\n\u003cp data-end=\"408\" data-start=\"328\"\u003eIntelligent dual locking system with\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"378\" data-start=\"365\"\u003eauto-lock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"408\" data-start=\"383\"\u003eone-touch manual lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong data-end=\"408\" data-start=\"383\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-G.jpg?v=1770741926\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-XL.jpg?v=1770748579\"\u003e\n\u003ch3\u003eOptions:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEPA Filtration System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-efficiency HEPA filtration for particulate contamination control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Hypoxic Cycle\u003c\/strong\u003e: Automated adjustments of O\u003csub\u003e2\u003c\/sub\u003e and CO\u003csub\u003e2\u003c\/sub\u003e concentrations for efficient sample stimulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated cable access for internal equipment connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSidewall Pipette Holder:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated sidewall-mounted pipette holder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Plate Entry System (SPES):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRapid single-plate transfer system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Temperature Chamber:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides controlled high-temperature environments (up to 55°C) for experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables low-temperature conditions for specialized experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicro-Pressure Chamber\u003c\/strong\u003e: Offer precise regulation of static pressure ranging from 0 to 35 KPa (0 to 5 PSI), with an adjustment accuracy of 0.1 KPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnaerobic System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombined hypoxic and anaerobic operation in one workstation\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdditional Options Shown Below\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Features:\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L-B.jpg?v=1770745268\" alt=\"\"\u003e\n\u003ch3\u003eProduct Dimensions:\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-XL-A.jpg?v=1770748842\"\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY_Hypoxia_Workstation_User_manual.pdf?v=1770826881\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MAWORDE","offers":[{"title":"290 (H)*280 (W)*350 (D)","offer_id":41231909158970,"sku":"MAWORDE-DY-XL","price":0.0,"currency_code":"USD","in_stock":true},{"title":"350 (H)*280 (W)*400(D)","offer_id":41231909191738,"sku":"MAWORDE-DY-XXL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-XL-B.jpg?v=1770749017"},{"product_id":"maworde-compact-hypoxia-workstation-support-cell-culture-research-under-hypoxic-conditions","title":"MAWORDE Compact Hypoxia Workstation - Support Cell Culture Research Under Hypoxic Conditions","description":"\u003ch2\u003eMAWORDE Compact Hypoxia Workstation - Support Cell Culture Research Under Hypoxic Conditions\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe DY-M is a compact hypoxia workstation designed to balance space efficiency with experimental precision, integrating operation, incubation, and observation in a single system. It enables simulation of in vivo hypoxic microenvironments and supports stable cell culture and research under controlled hypoxic conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"9826b31\" class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\"\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"8777c75\" class=\"elementor-element elementor-element-8777c75 elementor-widget elementor-widget-text-editor\"\u003e\n\u003ch3\u003eKey Specification:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"c7b6f5b\" class=\"elementor-element elementor-element-c7b6f5b elementor-widget elementor-widget-text-editor\"\u003e\n\u003cp\u003eOur workstation ensures precise, reliable culture conditions with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–20.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control\u003c\/strong\u003e: Room humidity to 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control\u003c\/strong\u003e: 3°C above ambient up to 45°C, in 0.1°C increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range\u003c\/strong\u003e: 0.00 – 0.50 kPa, in 0.01kPa increments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003ePrecise O\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; CO\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003eControl\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"7706630\" class=\"elementor-element elementor-element-7706630 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul data-end=\"459\" data-start=\"94\"\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments (upgradeable to 0–60.0%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cstrong data-end=\"473\" data-start=\"442\"\u003eOptional Built-in Air Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for an external compressed air source (O₂ control range: 0.1%–18%)\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"598\" data-start=\"568\"\u003eOptional Anaerobic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables integrated hypoxia\/anaerobic dual-mode operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-A.jpg?v=1770741479\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-f6f81d1 elementor-widget elementor-widget-heading\" data-id=\"f6f81d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSeamless Entry System (SES)\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-d76275d elementor-widget elementor-widget-text-editor\" data-id=\"d76275d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eRapid sleeve evacuation establishes an anaerobic barrier within\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"677\" data-end=\"691\"\u003e12 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eMaintains continuous and stable hypoxic conditions during routine operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"759\" data-end=\"851\"\u003e\n\u003cp data-start=\"761\" data-end=\"851\"\u003e\u003cstrong data-start=\"761\" data-end=\"785\"\u003e90° quick-open ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenable intuitive handling and improved internal space utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"852\" data-end=\"924\"\u003e\n\u003cp data-start=\"854\" data-end=\"924\"\u003eFlexible operation modes adapt to different workflows and user habits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-B.jpg?v=1770741554\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-3fda69b elementor-widget elementor-widget-heading\" data-id=\"3fda69b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eAdvanced Gas Circulation Design\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-e4a324d elementor-widget elementor-widget-text-editor\" data-id=\"e4a324d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eOptimized airflow and circulation paths ensure uniform temperature, humidity, and gas concentration distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eHigh-performance axial fans enable rapid gas exchange and even diffusion for long-term culture stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eIntegrated bent-panel construction with anti-condensation viewing window technology ensures clear visibility and enhanced durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-C.jpg?v=1770741634\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-dd1dd7f elementor-widget elementor-widget-heading\" data-id=\"dd1dd7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMulti-Stage Hypoxia Cycle\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-e2d8c4f elementor-widget elementor-widget-text-editor\" data-id=\"e2d8c4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eSupports 4, 10, or more automated gas cycling stages to suit different experimental needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eUsers can set cycle duration, gas concentrations, and the number of cycles according to their experiment requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-D.jpg?v=1770741732\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-0568282 elementor-widget elementor-widget-heading\" data-id=\"0568282\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSpecial Interlock Purge System\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\" data-id=\"10fdcf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003e\u003cstrong data-start=\"148\" data-end=\"164\" data-is-only-node=\"\"\u003eRapid purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically detects the oxygen level in the workspace and adjusts the interlock O₂ concentration to match\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003e\u003cstrong data-start=\"288\" data-end=\"305\"\u003eCustom purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows on-screen setting of O₂ purge concentration from 0 to 20.9% for special operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-E.jpg?v=1770741797\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-7872eea elementor-widget elementor-widget-heading\" data-id=\"7872eea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eHEPA Filtration \u0026amp; Pressure Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\" data-id=\"f88d3a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"96\" data-end=\"209\"\u003e\n\u003cp data-start=\"98\" data-end=\"209\"\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"109\" data-end=\"128\"\u003eH14 HEPA filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"139\" data-end=\"146\"\u003eU16\u003c\/strong\u003e) effectively protects samples from particulate contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"210\" data-end=\"333\"\u003e\n\u003cp data-start=\"212\" data-end=\"333\"\u003eHigh-response pressure relief valve precisely manages sudden pressure fluctuations, ensuring system and operator safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"334\" data-end=\"468\"\u003e\n\u003cp data-start=\"336\" data-end=\"468\"\u003eBuilt-in pressure-stabilizing water\/oil reservoir buffers continuous pressure changes, maintaining a stable experimental environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-F.jpg?v=1770741857\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"ead80d7\" class=\"elementor-element elementor-element-ead80d7 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eIntelligent Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"a432df3\" class=\"elementor-element elementor-element-a432df3 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"145\" data-start=\"96\"\u003e\n\u003cp data-end=\"145\" data-start=\"98\"\u003eAutomatic alarm for low gas cylinder pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"190\" data-start=\"146\"\u003e\n\u003cp data-end=\"190\" data-start=\"148\"\u003eReal-time chamber pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"263\" data-start=\"191\"\u003e\n\u003cp data-end=\"263\" data-start=\"193\"\u003eAutomatic leak detection with alarm and reduced gas intake frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"408\" data-start=\"326\"\u003e\n\u003cp data-end=\"408\" data-start=\"328\"\u003eIntelligent dual locking system with\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"378\" data-start=\"365\"\u003eauto-lock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"408\" data-start=\"383\"\u003eone-touch manual lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong data-end=\"408\" data-start=\"383\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-G.jpg?v=1770741926\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-M.jpg?v=1770749523\" alt=\"\"\u003e\n\u003ch3\u003eOptions:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEPA Filtration System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-efficiency HEPA filtration for particulate contamination control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Hypoxic Cycle\u003c\/strong\u003e: Automated adjustments of O\u003csub\u003e2\u003c\/sub\u003e and CO\u003csub\u003e2\u003c\/sub\u003e concentrations for efficient sample stimulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated cable access for internal equipment connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSidewall Pipette Holder:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated sidewall-mounted pipette holder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Plate Entry System (SPES):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRapid single-plate transfer system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Temperature Chamber:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides controlled high-temperature environments (up to 55°C) for experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables low-temperature conditions for specialized experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicro-Pressure Chamber\u003c\/strong\u003e: Offer precise regulation of static pressure ranging from 0 to 35 KPa (0 to 5 PSI), with an adjustment accuracy of 0.1 KPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnaerobic System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombined hypoxic and anaerobic operation in one workstation\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdditional Options Shown Below\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Features:\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L-B.jpg?v=1770745268\" alt=\"\"\u003e\n\u003ch3\u003eProduct Dimensions:\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-M-A.jpg?v=1770749768\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY_Hypoxia_Workstation_User_manual.pdf?v=1770826881\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MAWORDE","offers":[{"title":"Default Title","offer_id":41231909224506,"sku":"MAWORDE-DY-M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-M-B.jpg?v=1770749878"},{"product_id":"maworde-mid-size-hypoxia-workstation-support-cell-culture-research-under-hypoxic-conditions","title":"MAWORDE Mid-Size Hypoxia Workstation - Support Cell Culture Research Under Hypoxic Conditions","description":"\u003ch2\u003eMAWORDE Mid-Size Hypoxia Workstation - Support Cell Culture Research Under Hypoxic Conditions\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe DY-L is a mid-size hypoxia workstation designed to balance space efficiency with experimental precision, integrating operation, incubation, and observation in a single system. It enables simulation of in vivo hypoxic microenvironments and supports stable cell culture and research under controlled hypoxic conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-b6d2d20 elementor-widget elementor-widget-text-editor\" data-id=\"b6d2d20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003ch3\u003eKey Specification:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-359dd0a elementor-widget elementor-widget-text-editor\" data-id=\"359dd0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cp\u003eOur workstation ensures precise, reliable culture conditions with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"144\" data-end=\"165\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"217\" data-end=\"239\" data-is-only-node=\"\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–20.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control\u003c\/strong\u003e: Room humidity to 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control\u003c\/strong\u003e: 3°C above ambient up to 45°C, in 0.1°C increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range\u003c\/strong\u003e: 0.00 – 0.50 kPa, in 0.01kPa increments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\" data-id=\"9826b31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003ePrecise O\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; CO\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003eControl\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-7706630 elementor-widget elementor-widget-text-editor\" data-id=\"7706630\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul data-start=\"94\" data-end=\"459\"\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"144\" data-end=\"165\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"217\" data-end=\"239\" data-is-only-node=\"\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments (upgradeable to 0–60.0%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cstrong data-start=\"442\" data-end=\"473\"\u003eOptional Built-in Air Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for an external compressed air source (O₂ control range: 0.1%–18%)\u003c\/li\u003e\n\u003cli data-start=\"94\" data-end=\"189\"\u003e\n\u003cp data-start=\"96\" data-end=\"189\"\u003e\u003cstrong data-start=\"568\" data-end=\"598\"\u003eOptional Anaerobic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables integrated hypoxia\/anaerobic dual-mode operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-A.jpg?v=1770741479\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"f6f81d1\" class=\"elementor-element elementor-element-f6f81d1 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSeamless Entry System (SES)\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"d76275d\" class=\"elementor-element elementor-element-d76275d elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"691\" data-start=\"611\"\u003e\n\u003cp data-end=\"691\" data-start=\"613\"\u003eRapid sleeve evacuation establishes an anaerobic barrier within\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"691\" data-start=\"677\"\u003e12 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"758\" data-start=\"692\"\u003e\n\u003cp data-end=\"758\" data-start=\"694\"\u003eMaintains continuous and stable hypoxic conditions during routine operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"851\" data-start=\"759\"\u003e\n\u003cp data-end=\"851\" data-start=\"761\"\u003e\u003cstrong data-end=\"785\" data-start=\"761\"\u003e90° quick-open ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenable intuitive handling and improved internal space utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"924\" data-start=\"852\"\u003e\n\u003cp data-end=\"924\" data-start=\"854\"\u003eFlexible operation modes adapt to different workflows and user habits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-B.jpg?v=1770741554\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"3fda69b\" class=\"elementor-element elementor-element-3fda69b elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eAdvanced Gas Circulation Design\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"e4a324d\" class=\"elementor-element elementor-element-e4a324d elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"277\" data-start=\"97\"\u003e\n\u003cp data-end=\"277\" data-start=\"99\"\u003eOptimized airflow and circulation paths ensure uniform temperature, humidity, and gas concentration distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"277\" data-start=\"97\"\u003e\n\u003cp data-end=\"277\" data-start=\"99\"\u003eHigh-performance axial fans enable rapid gas exchange and even diffusion for long-term culture stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"277\" data-start=\"97\"\u003e\n\u003cp data-end=\"277\" data-start=\"99\"\u003eIntegrated bent-panel construction with anti-condensation viewing window technology ensures clear visibility and enhanced durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-C.jpg?v=1770741634\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"dd1dd7f\" class=\"elementor-element elementor-element-dd1dd7f elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMulti-Stage Hypoxia Cycle\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"e2d8c4f\" class=\"elementor-element elementor-element-e2d8c4f elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"691\" data-start=\"611\"\u003e\n\u003cp data-end=\"691\" data-start=\"613\"\u003eSupports 4, 10, or more automated gas cycling stages to suit different experimental needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"758\" data-start=\"692\"\u003e\n\u003cp data-end=\"758\" data-start=\"694\"\u003eUsers can set cycle duration, gas concentrations, and the number of cycles according to their experiment requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-D.jpg?v=1770741732\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"0568282\" class=\"elementor-element elementor-element-0568282 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSpecial Interlock Purge System\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"10fdcf5\" class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"277\" data-start=\"97\"\u003e\n\u003cp data-end=\"277\" data-start=\"99\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"164\" data-start=\"148\"\u003eRapid purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically detects the oxygen level in the workspace and adjusts the interlock O₂ concentration to match\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"277\" data-start=\"97\"\u003e\n\u003cp data-end=\"277\" data-start=\"99\"\u003e\u003cstrong data-end=\"305\" data-start=\"288\"\u003eCustom purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows on-screen setting of O₂ purge concentration from 0 to 20.9% for special operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-E.jpg?v=1770741797\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"7872eea\" class=\"elementor-element elementor-element-7872eea elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eHEPA Filtration \u0026amp; Pressure Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"f88d3a8\" class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"209\" data-start=\"96\"\u003e\n\u003cp data-end=\"209\" data-start=\"98\"\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"128\" data-start=\"109\"\u003eH14 HEPA filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"146\" data-start=\"139\"\u003eU16\u003c\/strong\u003e) effectively protects samples from particulate contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"333\" data-start=\"210\"\u003e\n\u003cp data-end=\"333\" data-start=\"212\"\u003eHigh-response pressure relief valve precisely manages sudden pressure fluctuations, ensuring system and operator safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"468\" data-start=\"334\"\u003e\n\u003cp data-end=\"468\" data-start=\"336\"\u003eBuilt-in pressure-stabilizing water\/oil reservoir buffers continuous pressure changes, maintaining a stable experimental environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-F.jpg?v=1770741857\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-ead80d7 elementor-widget elementor-widget-heading\" data-id=\"ead80d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eIntelligent Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-a432df3 elementor-widget elementor-widget-text-editor\" data-id=\"a432df3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"96\" data-end=\"145\"\u003e\n\u003cp data-start=\"98\" data-end=\"145\"\u003eAutomatic alarm for low gas cylinder pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"146\" data-end=\"190\"\u003e\n\u003cp data-start=\"148\" data-end=\"190\"\u003eReal-time chamber pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"191\" data-end=\"263\"\u003e\n\u003cp data-start=\"193\" data-end=\"263\"\u003eAutomatic leak detection with alarm and reduced gas intake frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"326\" data-end=\"408\"\u003e\n\u003cp data-start=\"328\" data-end=\"408\"\u003eIntelligent dual locking system with\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"365\" data-end=\"378\"\u003eauto-lock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"383\" data-end=\"408\"\u003eone-touch manual lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong data-start=\"383\" data-end=\"408\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-G.jpg?v=1770741926\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L-A.jpg?v=1770744238\"\u003e\n\u003ch3\u003eOptions:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEPA Filtration System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-efficiency HEPA filtration for particulate contamination control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Hypoxic Cycle\u003c\/strong\u003e: Automated adjustments of O\u003csub\u003e2\u003c\/sub\u003e and CO\u003csub\u003e2\u003c\/sub\u003e concentrations for efficient sample stimulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated cable access for internal equipment connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSidewall Pipette Holder:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated sidewall-mounted pipette holder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Plate Entry System (SPES):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRapid single-plate transfer system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Temperature Chamber:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides controlled high-temperature environments (up to 55°C) for experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables low-temperature conditions for specialized experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicro-Pressure Chamber\u003c\/strong\u003e: Offer precise regulation of static pressure ranging from 0 to 35 KPa (0 to 5 PSI), with an adjustment accuracy of 0.1 KPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnaerobic System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombined hypoxic and anaerobic operation in one workstation\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdditional Options Shown Below\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Features:\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L-B.jpg?v=1770745268\" alt=\"\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eProduct Dimensions:\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L-C.jpg?v=1770745569\"\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY_Hypoxia_Workstation_User_manual.pdf?v=1770826881\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MAWORDE","offers":[{"title":"Default Title","offer_id":41231909257274,"sku":"MAWORDE-DY-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L_74846253-2598-4b6f-a8da-a18a6a618f01.jpg?v=1770743507"},{"product_id":"maworde-hypoxia-workstation-with-maximum-workspace-with-three-glove-configuration","title":"MAWORDE Hypoxia Workstation with Maximum Workspace with Three-Glove Configuration","description":"\u003ch2\u003e\u003cspan\u003eMAWORDE Hypoxia Workstation with Maximum Workspace with Three-Glove Configuration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe DY-TM is Maworde largest standard hypoxia workstation, integrating operation, incubation, and observation in a single system. It enables simulation of in vivo hypoxic microenvironments and supports stable cell culture and research under controlled hypoxic conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"63b381e\" class=\"elementor-element elementor-element-63b381e elementor-widget elementor-widget-text-editor\"\u003e\n\u003ch3\u003eKey Specification:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"16167ea\" class=\"elementor-element elementor-element-16167ea elementor-widget elementor-widget-text-editor\"\u003e\n\u003cp\u003eOur workstation ensures precise, reliable culture conditions with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–20.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Control\u003c\/strong\u003e: Room humidity to 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control\u003c\/strong\u003e: 3°C above ambient up to 45°C, in 0.1°C increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range\u003c\/strong\u003e: 0.00 – 0.50 kPa, in 0.01kPa increments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"9826b31\" class=\"elementor-element elementor-element-9826b31 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003ePrecise O\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; CO\u003csmall\u003e\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003cspan\u003e \u003c\/span\u003eControl\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"7706630\" class=\"elementor-element elementor-element-7706630 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul data-end=\"459\" data-start=\"94\"\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"165\" data-start=\"144\"\u003eO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1%–25.0%, in 0.1% increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-is-only-node=\"\" data-end=\"239\" data-start=\"217\"\u003eCO₂ Control Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0%–20.0%, in 0.1% increments (upgradeable to 0–60.0%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cstrong data-end=\"473\" data-start=\"442\"\u003eOptional Built-in Air Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for an external compressed air source (O₂ control range: 0.1%–18%)\u003c\/li\u003e\n\u003cli data-end=\"189\" data-start=\"94\"\u003e\n\u003cp data-end=\"189\" data-start=\"96\"\u003e\u003cstrong data-end=\"598\" data-start=\"568\"\u003eOptional Anaerobic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables integrated hypoxia\/anaerobic dual-mode operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-A.jpg?v=1770741479\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-f6f81d1 elementor-widget elementor-widget-heading\" data-id=\"f6f81d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSeamless Entry System (SES)\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-d76275d elementor-widget elementor-widget-text-editor\" data-id=\"d76275d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eRapid sleeve evacuation establishes an anaerobic barrier within\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"677\" data-end=\"691\"\u003e12 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eMaintains continuous and stable hypoxic conditions during routine operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"759\" data-end=\"851\"\u003e\n\u003cp data-start=\"761\" data-end=\"851\"\u003e\u003cstrong data-start=\"761\" data-end=\"785\"\u003e90° quick-open ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenable intuitive handling and improved internal space utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"852\" data-end=\"924\"\u003e\n\u003cp data-start=\"854\" data-end=\"924\"\u003eFlexible operation modes adapt to different workflows and user habits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-B.jpg?v=1770741554\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-3fda69b elementor-widget elementor-widget-heading\" data-id=\"3fda69b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eAdvanced Gas Circulation Design\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-e4a324d elementor-widget elementor-widget-text-editor\" data-id=\"e4a324d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eOptimized airflow and circulation paths ensure uniform temperature, humidity, and gas concentration distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eHigh-performance axial fans enable rapid gas exchange and even diffusion for long-term culture stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003eIntegrated bent-panel construction with anti-condensation viewing window technology ensures clear visibility and enhanced durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-C.jpg?v=1770741634\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-dd1dd7f elementor-widget elementor-widget-heading\" data-id=\"dd1dd7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eMulti-Stage Hypoxia Cycle\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-e2d8c4f elementor-widget elementor-widget-text-editor\" data-id=\"e2d8c4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"611\" data-end=\"691\"\u003e\n\u003cp data-start=\"613\" data-end=\"691\"\u003eSupports 4, 10, or more automated gas cycling stages to suit different experimental needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"758\"\u003e\n\u003cp data-start=\"694\" data-end=\"758\"\u003eUsers can set cycle duration, gas concentrations, and the number of cycles according to their experiment requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-D.jpg?v=1770741732\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-0568282 elementor-widget elementor-widget-heading\" data-id=\"0568282\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eSpecial Interlock Purge System\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-10fdcf5 elementor-widget elementor-widget-text-editor\" data-id=\"10fdcf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003e\u003cstrong data-start=\"148\" data-end=\"164\" data-is-only-node=\"\"\u003eRapid purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically detects the oxygen level in the workspace and adjusts the interlock O₂ concentration to match\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"97\" data-end=\"277\"\u003e\n\u003cp data-start=\"99\" data-end=\"277\"\u003e\u003cstrong data-start=\"288\" data-end=\"305\"\u003eCustom purge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows on-screen setting of O₂ purge concentration from 0 to 20.9% for special operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-E.jpg?v=1770741797\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-7872eea elementor-widget elementor-widget-heading\" data-id=\"7872eea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eHEPA Filtration \u0026amp; Pressure Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-f88d3a8 elementor-widget elementor-widget-text-editor\" data-id=\"f88d3a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"96\" data-end=\"209\"\u003e\n\u003cp data-start=\"98\" data-end=\"209\"\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"109\" data-end=\"128\"\u003eH14 HEPA filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"139\" data-end=\"146\"\u003eU16\u003c\/strong\u003e) effectively protects samples from particulate contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"210\" data-end=\"333\"\u003e\n\u003cp data-start=\"212\" data-end=\"333\"\u003eHigh-response pressure relief valve precisely manages sudden pressure fluctuations, ensuring system and operator safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"334\" data-end=\"468\"\u003e\n\u003cp data-start=\"336\" data-end=\"468\"\u003eBuilt-in pressure-stabilizing water\/oil reservoir buffers continuous pressure changes, maintaining a stable experimental environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-F.jpg?v=1770741857\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv data-widget_type=\"heading.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"ead80d7\" class=\"elementor-element elementor-element-ead80d7 elementor-widget elementor-widget-heading\"\u003e\n\u003ch3 class=\"elementor-heading-title elementor-size-default\"\u003eIntelligent Safety Protection\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-widget_type=\"text-editor.default\" data-e-type=\"widget\" data-element_type=\"widget\" data-id=\"a432df3\" class=\"elementor-element elementor-element-a432df3 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"145\" data-start=\"96\"\u003e\n\u003cp data-end=\"145\" data-start=\"98\"\u003eAutomatic alarm for low gas cylinder pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"190\" data-start=\"146\"\u003e\n\u003cp data-end=\"190\" data-start=\"148\"\u003eReal-time chamber pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"263\" data-start=\"191\"\u003e\n\u003cp data-end=\"263\" data-start=\"193\"\u003eAutomatic leak detection with alarm and reduced gas intake frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"408\" data-start=\"326\"\u003e\n\u003cp data-end=\"408\" data-start=\"328\"\u003eIntelligent dual locking system with\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"378\" data-start=\"365\"\u003eauto-lock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"408\" data-start=\"383\"\u003eone-touch manual lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong data-end=\"408\" data-start=\"383\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-G.jpg?v=1770741926\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-I.jpg?v=1770749127\"\u003e\u003cbr\u003e\n\u003ch3\u003eOptions:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEPA Filtration System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-efficiency HEPA filtration for particulate contamination control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Hypoxic Cycle\u003c\/strong\u003e: Automated adjustments of O\u003csub\u003e2\u003c\/sub\u003e and CO\u003csub\u003e2\u003c\/sub\u003e concentrations for efficient sample stimulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated cable access for internal equipment connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSidewall Pipette Holder:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated sidewall-mounted pipette holder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Plate Entry System (SPES):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRapid single-plate transfer system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Temperature Chamber:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides controlled high-temperature environments (up to 55°C) for experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables low-temperature conditions for specialized experiments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicro-Pressure Chamber\u003c\/strong\u003e: Offer precise regulation of static pressure ranging from 0 to 35 KPa (0 to 5 PSI), with an adjustment accuracy of 0.1 KPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnaerobic System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombined hypoxic and anaerobic operation in one workstation\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdditional Options Shown Below\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Features:\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-L-B.jpg?v=1770745268\" alt=\"\"\u003e\n\u003ch3\u003eProduct Dimensions:\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM-H.jpg?v=1770743113\"\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY_Hypoxia_Workstation_User_manual.pdf?v=1770826881\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MAWORDE","offers":[{"title":"Default Title","offer_id":41231909290042,"sku":"MAWORDE-DY-TM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7785\/files\/DY-TM_10aac693-6578-4745-ac6e-82d4237f58aa.jpg?v=1770741340"}],"url":"https:\/\/www.msesupplies.com\/collections\/hypoxia-workstations.oembed","provider":"MSE Supplies","version":"1.0","type":"link"}